Haier HP200M3 Скачать руководство пользователя страница 1

 

Heat Pump Water Heater 

Installation and Service Manual 

 

 

 

 

Model 

HP200M3 

HP250M3 

HP250M3C 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please read this manual carefully prior to your use of this water heater. 

The appearance of the water heater given in this manual is for reference only. 

Содержание HP200M3

Страница 1: ...eater Installation and Service Manual Model HP200M3 HP250M3 HP250M3C Please read this manual carefully prior to your use of this water heater The appearance of the water heater given in this manual is for reference only ...

Страница 2: ...principles 4 3 Technical parameters 5 4 Description of parts and components 6 5 Installation introduction 11 6 Operating and settings 22 7 Faults and protection 25 8 Faults and protection 26 9 The method of dismantling products 33 10 Repairs common tools 38 ...

Страница 3: ... Children shall be closely supervised to make sure they stay away from this product 3 The method of installing safety valve please refer to Page 16 4 The water may drip from the discharge pipe of the pressure relief device and this pipe must be left open to the atmosphere 5 The water heater is to be drained according to the instructions specified on page 27 Safety instructions to be followed at an...

Страница 4: ...ure of the refrigerant increases so does its temperature The heated refrigerant runs through a condenser coil within the storage tank transferring heat to the water stored there As the refrigerant delivers its heat to the water it cools and condenses and then passes through an expansion valve where the pressure is reduced and the cycle starts over ...

Страница 5: ...eatinguptime 14 4 68h 6 17h 6h Default temperature setting 55 55 55 Temperature setting range withheater 35 75 35 75 35 75 Maximumlengthofairinletduct 2 5m 2 5m 2 5m Maximumlengthofairoutletduct 2 5m 2 5m 2 5m Maxworkingpressureofrefrigerant 0 8 2 8MPa 0 8 2 8MPa 0 8 2 8MPa Refrigerant type weight R134a 0 9kg R134a 0 9kg R134a 0 9kg Sound powerlevel 57dB 58dB 59dB Ambienttemperature foruseofproduc...

Страница 6: ...6 4 Description of parts and components Heat pump structure HP200M3 HP250M3 ...

Страница 7: ...7 Heat pump structure HP250M3C ...

Страница 8: ... The compressor is to effect a low temperature low pressure evaporator refrigerant vapor sucked and compressed into high temperature and pressure of the superheated vapor and then discharged to the condenser heat exchanger Intake pipe Exhaust pipe Wiring box ...

Страница 9: ...arge heat the heat is absorbed by the heating medium 4 Electronic expansion valve The refrigerant passes through the electric expansion valve the pressure from the condensing pressure is reduced to the evaporation pressure part of the refrigerant will evaporate into gas in the throttling process 5 Filter It s interior has a filter and desiccant the desiccant absorbs moisture from the refrigerant t...

Страница 10: ... the high voltage switch is 2 8MPa 7 Service valve Service valve is mainly used for filling refrigerant after removing the nuts it contains a valve needle sales staff can vacuum infusion refrigerant from here 8 Fan It forced air through the duct and then flows through a heat exchanger to improve heat transfer efficiency of the heat exchanger Service valve nuts ...

Страница 11: ...ient space left for installation and maintenance There is no strong electromagnetic interference around that may affect control functions There is no sulfur gas or mineral oil existing at the installation place which may cause corrosion of the machine and the fittings The water pipe for the water heater used at temperatures below 0 C shall not freeze It shall not be set in rooms where a heating sy...

Страница 12: ...12 from 10 to 35 C Keep an adequate distance between the working heat pump and the resting places b Installation dimensions mm ...

Страница 13: ...13 c Installation angle refer to the following diagrams Pipe connection ...

Страница 14: ...Diameter of air connection 160 mm c Advised positions Garage or laundry room without ducts Unheated room Enables recovery of the free energy released by your vehicle s engine when switched off after use or by household appliances in operation Laundry room with one duct Unheated room Enables recovery of the free energy released by your vehicle s engine when switched off after use or by household ap...

Страница 15: ... be added at the water inlet The inlet water temperature is suggested between 10 30 C Outdoor water pipeline and valves should be proper insulated In accordance with safety rules a safety valve 7bar 99 C G3 4M must be installed on the tank For France we recommend hydraulic safety units fitted with a membrane with the NF marking Integrate the safety valve in the cold water circuit Install the safet...

Страница 16: ...isk of corrosion It is compulsory to fit the domestic hot water connection with a dielectric connection not supplied Pressure relief valve thermostatic valve stop valve check valve T P valve and French combination valve are not included in the accessories please select proper fittings in local market Valves with NF CE certification are recommended ...

Страница 17: ...17 e Connection to solar collectors Version HP250M3C WARING Plumber Be Aware Using solar energy please make sure that the heat pump water tank temperature not more than 85 ...

Страница 18: ...18 f Connection to gas boiler Version HP250M3C ...

Страница 19: ...ards Water heaters shall be equipped with a dedicated power line and residual current circuit breakers The action current shall not exceed 30 mA The ground line and the zero line of the power supply shall be separated entirely Connecting the zero line to the ground line is not allowed Parameter of the power line 3 1 5mm or more If a power cable is damaged it shall be replaced by qualified professi...

Страница 20: ...The phase line zero line and ground line inside a power socket used in your home shall be wired correctly without any wrong positioning or false connection and internal short circuit shall be avoided Wrong wiring may cause fire accidents h Connection with timer programming Connection with the meter with direct contact Connection with boiler back up only for HP250CM2 ...

Страница 21: ...21 Boiler signal line 2 0 75mm2 Connect the boiler back up connector boiler back up refer to the boiler instruction manual Referring installer menu adjust the parameters and i Wiring diagram ...

Страница 22: ...l Automatic defrosting function The defrosting mode is automatically activated if the ambient temperature is too low and after the compressor already runs continuously for a certain period Overload protection The working load of the compressor will be heavy if temperature is high in summer In order to meet hot water requirements of users and to lengthen service life of the compressor this product ...

Страница 23: ...23 Description of the pictograms ...

Страница 24: ... To open the installer settings press switch off the system then press and at the same time for 10 seconds When menu is open press or to change the value of the settings Press to confirm the settings Press to close the menu ...

Страница 25: ...porator Clean the evaporator at regular intervals using a soft haired brush If they are bent Carefully realign the evaporator using a suitable comb Because the evaporator fins is very sharp Risk of injury on your finger Do not damage the fins Avoid affecting the performance Checking the condensates discharge pipe Check the pipe cleanliness An obstruction by dust may cause poor condensates flow or ...

Страница 26: ...26 8 Faults and protection ...

Страница 27: ...27 Fault code identification method ...

Страница 28: ...28 ...

Страница 29: ...29 ...

Страница 30: ...30 ...

Страница 31: ...ing the resistance value of the compressor of the same but is switched to the small resistance of the interface unit Multimeter set to Ohms according to the picture of the method of measuring the resistance of the temperature sensor According to the resistance table the lower the temperature the smaller the resistance ...

Страница 32: ...ircuited Press the yellow button to switch to the picture when a short circuit there is a beep the resistance is zero Check the tank heater for leaks Press the yellow button to switch to the picture shown turn the heating power measurements if leakage resistance is zero if not leak show resistance ...

Страница 33: ...the same order into the leakage protection coil 9 The method of dismantling products Make sure the power cord is disconnected 1 Remove the Display 2 Remove the Cover Use a screwdriver to remove the two screws Use a screwdriver to remove the screws ...

Страница 34: ...you need to replace 5 Remove the temperature sensor Remove the fixing screws remove the water tank flange cover Remove the temperature sensors and thermostat temperature sensor magnesium rod cover magnesium rod Temperature tube up Temperature tube down First insert the temperature sensor and then insert the thermostat temperature sensor to Temperature tube down Temperature sensor must be inserted ...

Страница 35: ...35 6 Open the control box Use a screwdriver to remove the 4 screws Controller panel ...

Страница 36: ... a screwdriver to remove the bottom two screws of the Front cover down Ambient temperature sensor yellow Exhaust temperature sensor white Intake sensor 1 red Evaporator sensor white Tank temperature sensor red Leakage protection coil Solar or boiler sensor Display panel Municipal low power switching signal ...

Страница 37: ...en leaked please check it as follows 1 Unscrew the maintenance valve nut access to nitrogen to maintain pressure 1MPa 2 Apply soap bubbles evenly over the solder joints of the copper tube Observe the changes in the status of soap bubbles to determine the location of leakage 3 After the professionals repair the welding leakage point check the leakage again with the above method until it is confirme...

Страница 38: ...e needle does not move for about 5 minutes 5 Disconnect the vacuum pump 6 Open the container of the refrigerant then open the main valve cap pressure gauge and adjust the needle valve until you hear the coolant leak and release the pin and close the valve of the pipe 7 Keep under control the weight of the refrigerant tank through the electronic scale 8 Open the ball valve and to flow the refrigera...

Страница 39: ...39 vacuum pump pressure gauge vacuum pump Electronic scales refrigerant cylinder manometer hose Service valve Heat pump ...

Страница 40: ...ools Name Quantity Illustration Spanner 2pc Hexagon Spanner 1pc Flathead screwdriver 1pc Phillips screwdriver 1pc Needle nose pliers 1pc Measuring tape 1pc Pressure gauge 1pc Vacuum pump 1pc Electronic scale 1pc Bending device 1pc ...