-33 -
Service Manual
Model No: 26A SERIES
Issue
Rev.
Chapter 10.
Order
Operation
Display and action
1
Press “Power” button and press two buttons(Function and Temp.) within 10 sec.The screen displays
“TEST”, the test programme will start, the LED lamp will light in turn.
2
Pressing “Function” button
3
4
The screen will display in turn:
A) “8888”
B
“7777”
only the motor is running;
C
“6666”
D
“5555”
only the fan will run 5 seconds;
E
"END"
5
Pressing “Dry level” button
The screen will display the programme version.
Pressing “Mode”button
The screen will display the temperature of NTC2 and NTC3 in turn
Test Programme
the motor ready to run;
Pressing“Selection”button
The third LED screen will display the state of water level switch:no water
is 0,full of water(there is much water to make floater up) is 1;
Pressing“Start Pause”button
The fouth LED screen will display the state of door switch:open is 0,close
is 1.
Put damp load in the drum.
Press”Dry level” button,the drum will run for 60
seconds and the motor
and the compressor begin to star at the same time.The screen will
display the humidity of load.
After 60 seconds,the screen display “end”.5 seconds later,the motor and
the compressor stop working.
only the pump will run 5 seconds;
Notice:dont open the door or turn the knob in the phase .