Haier HCC2230AGS Скачать руководство пользователя страница 15

 

-

 

To adjust the flame, remove the knobs, insert a screwdriver through the access hole in valve 

shaft as shown (see Figure 25).  Make the adjustment by slowly turning the screw until flame 

appearance is correct. 

 

-

 

If the flames are too small or fluttered, open the valve more than the original setting. 

-

 

If the flames are too large, close the valve more than the original setting. 

 

D.  TESTING FLAME STABILITY 

 

Test 1

——

Turn the knob from “HI” to “LO” quickly.  If the upper row of flames goes out at this setting, 

increase the flame size and test again.

 

Test 2

——

With the burner on “LO”, open and close the cabinet door under the cooktop.  If the flame 

is extinguished by the air currents created by the door movement, increase the flame height and test 

again. 

 

E.  FLAME RE-CHECK 

 

After the adjustment is made, turn all burners off.  Ignite each burner individually.  Observe the flame 

at the “HI” position.  Rotate the knob to the lowest setting and be sure that the flame size decreases 

as the knob is rotated counter-clockwise. 

 

 

Once the conversion has been completed and has passed testing, fill out the conversion 

sticker and include your name, organization and the date conversion is made.  Apply the 

sticker near the cooktop gas inlet opening to alert others in the future that this appliance has 

been converted. If converting back to Natural Gas, please remove the sticker so others know 

that the appliance is set to use its original gas. 

 

 

Figure 25 

Содержание HCC2230AGS

Страница 1: ...Tables de cuisson gaz de 24 et 30 Superficies de cocci n a gas de 24 y 30 Installation Instructions Instructions d installation Instrucciones de instalaci n HCC2230AGS HCC3230AGS ON MIN OFF ON MIN OFF...

Страница 2: ...bstructed from inside or outside or constructed close to the floor The opening is recommended to be on the side opposite to that on which the flue gases are discharged Avoid placing cabinetry directly...

Страница 3: ...NFPA No 70 latest edition in United States or in Canada CSA Standard C22 1 Canadian Electrical Code Part 1 and local code requirements Gas supply should be located near the opening for this cooktop a...

Страница 4: ...t Pipe Fittings Shut Off Valve CSA Approved Flexible or Gas Line TOOLS YOU WILL NEED Pencil Phillips Head Screwdriver Ruler Safety Glasses Saber Saw Pipe Wrench 1 8 Drill Bit Electric or Hand Drill Cu...

Страница 5: ...e inserting the cooktop into the opening in the countertop remove the grates and burner caps turn the cooktop upside down and place the special foam gasket around the bottom edge of the cooktop see Fi...

Страница 6: ...LP or Natural gases to all threaded connections This cooktop is set for natural gas and is designed to operate at 5 water column pressure The gas supply is required to provide a minimum of 6 to a maxi...

Страница 7: ...Make sure that the type of gas to be supplied to the appliance is the same as that shown on the label affixed to the underside of the cooktop 3 Make the connection to the gas system using a rigid or...

Страница 8: ...idual manual shutoff valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5 kPa or 14 water column Isolate the cooktop from the...

Страница 9: ...de of a burner while another is turned on Damage or electrical shock may occur 1 Place burner heads over the burner base Make sure the hole in the burner head is properly aligned with the electrode in...

Страница 10: ...king sounds but only the burner turned to LITE will light LP Propane Gas Conversion This appliance can be used with Natural Gas or LP Propane gas It is shipped from the factory for use with natural ga...

Страница 11: ...0 73 Semi Rapid Burners 2 0 55 1 x 1 20 0 19 1 x 0 80 124 Rapid Burner 3 0 8 1 x 1 45 0 29 1 x 0 91 182 Triple Ring Burner 4 5 1 5 5 x 0 99 0 43 5 x 0 56 327 WARNING Failure to make the appropriate co...

Страница 12: ...1 Unscrew the regulator cap with the wrench see Figure 19 2 This is how the retainer pin looks for Natural Gas usage see Figure 20 3 Remove the retainer pin see Figure 21 Figure 19 Figure 20 Figure 21...

Страница 13: ...or and re attach the regulator to the nipple and flare union see Figures 14 and 23 B CHANGE BURNER NOZZLES INSTALLATION TIP First remove all nozzles and then start replacing them This will help to pre...

Страница 14: ...ames They should be blue in color and may have some yellow tipping at the ends of the flame when using LP gas Foreign particles in the gas line may cause an orange flame at first but this will soon di...

Страница 15: ...ktop If the flame is extinguished by the air currents created by the door movement increase the flame height and test again E FLAME RE CHECK After the adjustment is made turn all burners off Ignite ea...

Страница 16: ...urs Haier Customer Satisfaction Center au 1 877 337 3639 UNE PREUVE D ACHAT DATEE EST REQUISE POUR BENEFICIER DE LA GARANTIE IMPORTANTE No regrese este producto a la tienda Si tiene alg n problema con...