![Haier H3PH-1J5K-EU4 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/haier/h3ph-1j5k-eu4/h3ph-1j5k-eu4_user-manual_4429200043.webp)
H3PH-1J6K-EU
8. Specifications
User Manual
42
Technical Data
H3PH-1J5K-EU
Max. input voltage
Start-up voltage
MPPT voltage range
MPPT number/Max input strings number
Max. input current
Battery Voltage range
Maximum charging Power
Rated output power
Max. apparent output power
Rated grid voltage
The grid voltage range
AC grid frequency range
Rating grid frequency
Power factor
THDi
Recommended max. PV power
Maximum Charge/discharge current
Communication
8000W
160V
200-850V
3/3
16A/16A/16A
5kW
25A
CAN/RS485
5kW
3/N/PE, 380V/400V
320-460V
45-55 Hz/ 55-65Hz
50 Hz/60 Hz
>
0.99 ( 0.8 leading to 0.8 lagging)
1000V
Battery Type
Li-ion
5kVA
9600W
Input DC (PV side)
Rated voltage
600V
Full load MPPT voltage range
200-850V
Max. short circuit current
24A/24A/24A
Battery
Output AC(Grid-side)
6kW
6kW
6kVA
Rating grid output current
Max. output current
7.6A/7.2A
9.1A/8.7A
<
3%
120 - 600Vdc
7.6A/7.2A
9.1A/8.7A