![Haier GV270REMB Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/haier/gv270remb/gv270remb_user-manual_3530291007.webp)
Diagram of pipeline installation
1. Any alteration to the structure of the solar
water heater may cause problems in use.
2. There are five ways to connect the water
pipe to the room: flue, vent hole, through-
hole in the wall, pipe well for solar pipes
and embedded sleeves, wherein the
former three types are commonly used.
Before installation, the installation staff will
consult the entry form and installation
location of the pipe in a comprehensive
way and in consideration of your
convenience. A slope in the through-wall
must be ensured during pipeline layout,
and sealing shall be guaranteed to prevent
the entry of rain or odors.
3. Keep the smoothness of the air pipe to
prevent the blockage of impurities, which
may lead to collapse and deformation of
the water tank under suction when using
water.
4. Do not install a valve in the overflow
pipeline to ensure that the flood signal can be sent out rapidly and accurately.
5. To avoid the return of water in the tank, a non-return valve shall be installed at the joint of the
water upward/downward pipes and the tap water.
6. The installation project should be confirmed by our professional service personnel when
installing several sets of the series of the products.
Connection of water supply pipes when the solar
water heater coexists with other water heaters
Please install another non-return valve
on the cold and hot water pipes
respectively if the solar heater coexists
with other water heaters so as to avoid
accidents caused by water returned to
the solar water tank through hot water
pipe due to high pressure in the tanks.
Tap water
Cold water
pipe
Other water
heater
To solar water tank
Non-return valve
Manual valve
Non-return
valve
Non-return valve
Solar energy hot
Mixing valve
Mixing valve
Hot water pipe
Installation instructions
Operation instructions
Warning
Notice:
Improper operation of the water heater may lead to serious burns. When using the heater,
do not make the water outlet of the nozzle aim at the body, mix the cold and hot water
before use.
Precautions on pipeline installation
Mixing valve (cold water)
E
le
c
tr
ic
h
e
a
tin
g
w
ir
e
S
e
n
s
o
r
w
ir
e
Inlet/outlet
pipe
Mixing valve
(hot water)
Solenoid valve
Solenoid valve wire
Non-return
valve
Manual valve
plug
Outdoor
Tap water
Air supply hole
controller
Indoor
Electric
heating
tube
Accompanying
heating
strap
Over flow port
S
e
n
s
o
r