Installation Preparation - UVC9420 and UVC9480

POWER SUPPLY

IMPORTANT – (Please read carefully)

FOR PERSONAL SAFETY, THIS APPLIANCE 
MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before 
beginning installation.
Do not use an extension cord or adapter plug with 
this appliance. Follow National Electrical Codes or 
prevailing local codes and ordinances.

Electrical supply

These vent hoods must be supplied with 120V, 
60Hz, and connected to an individual, properly 
grounded branch circuit, and protected by a 15 or 20 
amp circuit breaker or time delay fuse.

Wiring must be 2 wire with ground.
If the electrical supply does not meet the above 
requirements, call a licensed electrician before 
proceeding.
Route house wiring as close to the installation 
location as possible in the ceiling or wall. 
Connect the wiring to the house wiring in 
accordance with local codes.

Grounding instructions

The grounding conductor must be connected to 
a ground metal, permanent wiring system, or an 
equipment-grounding terminal or lead on the hood.

 The improper connection of the 

equipment-grounding conductor can result in a risk 
of electric shock. Check with a qualified electrician 
or service representative if you are in doubt whether 
the appliance is properly grounded.

PREPARE HOUSE ELECTRICAL 
WIRING

The custom cabinet must allow spacing for house 
wiring to reach junction box located in diagram 
below. If unit is installed over an island, the wiring 
must come from ceiling. If power cord is needed, 
accessory is available.

PREPARE THE HOOD FOR 
INSTALLATION

NOTE:

 For transportation purposes the motor 

assembly is secured by 2 brackets. They must be 
removed prior to installation and discarded.

Place insert hood canopy on padded, yet stable, 
surface below cutout (can use flattened carton to 
pad surface).
Remove the junction 
box cover. The junction 
box  is located inside 
the top left side of the 
hood.
Save the junction 
box cover and 
screws. They will be 
needed at installation.
Remove the 12 screws from the brackets 
over the motor assembly to remove the brackets.

The junction box is 

located in this area 

inside the hood.

Electrical
Area

24"

Brackets

Screws

IN

S

TA

L

L

A

T

IO

N

 P

R

E

P

A

R

A

T

IO

N

Содержание GE UVC9420

Страница 1: ...prominent warning device such as a tag to the service panel Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION Disconnect all electrical power at the main circuit breaker or fuse box before installing TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A I...

Страница 2: ...with duct tape to prevent any leaks NOTE Flexible vent is not recommended Flexible vent creates back pressure and air turbulence that greatly reduces performance foot for vent hoods exterior opening Purchase the wall or roof cap and any transition and length of duct needed in advance Vent system can terminate either through the roof needed and installed immediately above the hood Wall and Ceiling ...

Страница 3: ... the cabinet surface NOTE UL requires any combustible surface to be a minimum of 30 above the cooking surface Lower combustible surfaces may be covered to meet requirements minimum for vertical venting installed over an island NOTE The exhaust duct on the hood is closer to the rear of the hood It is important to plan for the alignment to the connection point of the hood 30 Minimum required 36 Maxi...

Страница 4: ...ured and able to withstand 100 pounds 2 Min 2 Min 39 Between Studs CUSTOM CABINET FRAME The custom canopy or cabinet must have a rectangular opening to accommodate the custom hood insert by itself This opening has the same size for both a wall installation or an island installation Ensure parallelism and levelness of the cabinet so that it doesn t affect flushness of the hood with the cabinet 39 F...

Страница 5: ...y secured and able to withstand 100 pounds C L 2 Min 2 Min 39 Between Studs CUSTOM CABINET FRAME The custom canopy or cabinet must have a rectangular opening to accommodate the custom hood insert by itself This opening has the same size for both a wall installation or an island installation Ensure parallelism and levelness of the cabinet so that it doesn t affect flushness of the hood with the cab...

Страница 6: ...r recycling options for your appliance packaging material TOOLS AND MATERIALS REQUIRED NOT SUPPLIED Pencil and tape measure Step ladder Phillips and flat blade screwdrivers Level Safety glasses 10 ducting and caps as needed Aluminized duct tape Electric drill and appropriate bits Gloves Flashlight Needle nose pliers Tin snips Wire cutter stripper Strain relief for junction box UL listed wire nuts ...

Страница 7: ... system or an equipment grounding terminal or lead on the hood The improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded PREPARE HOUSE ELECTRICAL WIRING The custom cabinet must allow spacing for house wiring to reach junction box loca...

Страница 8: ... source If house wiring is not 2 wire with a ground wire an electrician will need to convert existing wiring to meet these specs When house wiring is aluminum be sure to use U L approved anti oxidant compound and aluminum to copper connectors 1 Pull power supply wires through wall of insert canopy and attach the strain relief Thread the house wire through the junction box before the canopy is inse...

Страница 9: ... house wiring out of the way 3 Push the hood canopy straight up through the cutout opening until the temporary locking clips engage The locking clips are designed to hold the insert sleeve in place until it is secured with screws 4 Once the hood canopy is in place seal the duct to the damper with duct tape DO NOT USE SCREWS INSTALLATION Installation UVC 9420 2x4 Stud ...

Страница 10: ... screws for installation 4 Remove the motor assembly from the hood canopy by sliding it to release it from the mounting tabs STEP 2 DAMPER AND SIDE PANEL INSTALLATION 1 Install the damper into the bottom of the exhaust fan opening using 2 screws provided D a Check to make sure the damper opens freely b Tighten the 2 screws D 2 Install the right and left side panels to the hood canopy using the 4 s...

Страница 11: ...f Hood Wiring A A D D E E B B F F C C Power Supply Strain Relief Strain Relief Wires STEP 4 INSTALL HOOD CANOPY TO THE CABINET 1 Confirm the damper is in place in the hood exhaust opening see previous page for instructions 2 Confirm the side panels are mounted see previous instructions 3 Tuck the house wiring out of the way 4 Push the hood canopy straight up through the cutout opening until the te...

Страница 12: ...er see Remove Motor Assembly from Hood Canopy section Make sure the blower motor is secured firmly to the hood canopy 4 Reconnect the 4 cables of the motor to the ones on the hood side and insert them into the protected area under the control panel 5 Mount the metal lid and tighten the 3 screws to secure the lid on the hood body Installation UVC 9420 and 9480 Slots on Hood Mounting Tabs Screws Met...

Страница 13: ...e engaged 4 Reinstall the 4 screws removed earlier See Remove Motor Assembly from Hood Canopy section Make sure the plate is secured firmly to the hood canopy 5 Lift and attach each motor using 4 screws per motor making sure they are firmly attached to the motor plate 6 With both motors installed on canopy reconnect the 4 cables of the motor to the ones on the hood side and insert them into the pr...

Страница 14: ... 1 Installation UVC 9420 and 9480 INSTALLATION STEP 6 FINALIZE INSTALLATION 1 Insert filters see the Filters section 2 Check operation of the lights and blower Refer to Using the Hood sections for operating instructions ...

Страница 15: ... of the Vent Hood Insufficient makeup replacement air Sufficient makeup replacement air is required for exhausting appliances to operate to rating Check with local building codes which may require or strongly advise the use of makeup air Visit GEAppliances com for available makeup air solutions Early light failure Light wattage is too high Replace with correct wattage Fan automatically turns on an...

Страница 16: ...24 49 2000930 Rev 1 Notes ...

Страница 17: ...49 2000930 Rev 1 25 Notes ...

Страница 18: ...year From the date of the original purchase Any part of the cooking product which fails due to a defect in materials or workmanship During this limited one year warranty GE Appliances will provide free of charge all labor and related service costs to replace the defective part This limited warranty is extended to the original purchaser and any succeeding owner for products purchased for home use w...

Страница 19: ...periences Refer to the Consumer Support page for phone numbers and website information The following products and more are available Accessories Parts Power Cord Kit Make up Air Kit Charcoal Filter Recirculation Kit Remote Control Cleaning Supplies CitruShine Stainless Steel Wipes Stainless Steel Appliance Cleaner Bar Keepers Friend Soft Cleanser ...

Страница 20: ... You can purchase it on line anytime GE Appliances Services will still be there after your warranty expires In the US GEAppliances com extended warranty or call 800 626 2224 during normal business hours In Canada GEAppliances com en support purchase extended warranty Remote Connectivity For assistance with wireless network connectivity for models with remote enable visit our website at GEAppliance...

Отзывы: