31-5000724 Rev. 0
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output *
(Btuh)
AFUE
(ICS)
Nominal*
Cooling
Capacity
Gas
Inlet
(in.)
Volts-
Hertz-
Phase
Max. Time
Delay
Breaker or
Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
DOWNFLOW
NF97D070M3B
66,000
64,000
97.0%
3 Tons
1/2
120-60-1
15
7.7
40
140
NF97D090M4C
88,000
85,000
97.0%
4 Tons
1/2
120-60-1
15
10.1
40
165
NF97D110M5C
110,000
107,000
97.0%
5 Tons
1/2
120-60-1
20
12.8
40
174
Note: For vent length and clearances to combustibles, please reference installation instructions.
* At full capacity
Technical Specifications - NF97DM
MODEL NUMBER GUIDE
MAJOR/MINOR REVISION
CABINET WIDTH
B - 17.5
C - 21.0
NOMINAL CFM
3 - 1200 CFM
4 - 1600 CFM
5 - 2000 CFM
DESIGN VARIANT
M - VARIABLE SPEED MODULATING
BRAND
N - GE
PRODUCT
F - FURNACE, GAS
AFUE
97 - 97% EFFICENCY
APPLICATION
D - DOWNFLOW
HEATING INPUT (1000 BTU/HR)
70, 90, 110,
N
N FF 97
97 D
D
M
M 55 C
C XX
XX
110
110