507332-02G / 31-5000663
Page 34 of 35
Issue 2209
Planned Service
The following items should be checked during an annual
inspection. Power to the unit must be shut off for the service
technician’s safety.
Fresh air grilles and louvers
(on the unit and in the
room where the furnace is installed) - Must be open and
unobstructed to provide combustion air.
Burners -
Must be inspected for rust, dirt, or signs of water.
Vent pipe -
Must be inspected for signs of water, damaged
or sagging pipe, or disconnected joints.
Unit appearance -
Must be inspected for rust, dirt, signs of
water, burnt or damaged wires, or components.
Blower access panel -
Must be properly in place and
provide a seal between the return air and the room where
the furnace is installed.
Return air duct -
Must be properly attached and provide
an air seal to the unit.
Operating performance -
Unit must be observed during
operation to monitor proper performance of the unit and
the vent system.
Combustion gases -
Flue products must be analyzed and
compared to the unit specifications.
Problems detected during the inspection may make it
necessary to temporarily shut down the furnace until the
items can be repaired or replaced.
Instruct the homeowners to pay attention to their
furnace
. Situations can arise between annual furnace
inspections that may result in unsafe operation. For
instance, items innocently stored next to the furnace may
obstruct the combustion air supply. This could cause
incomplete combustion and the production of carbon
monoxide gas.
Repair Parts List
The following repair parts are available through independent GEA dealers. When ordering parts, include the complete
furnace model number listed on the CSA International nameplate. All service must be performed by a licensed professional
installer (or equivalent), service agency, or gas supplier.
Cabinet Parts
• Upper access panel
• Blower panel
• Top cap
Control Panel
• Parts Transformer
• Integrated control
• Door interlock switch
• Circuit breaker
Blower Parts
• Blower wheel
• Blower housing
• Motor
• Motor mounting frame
• Motor capacitor
•
Blower housing cutoff plate
Heating Parts
• Flame sensor
•
Heat exchanger assembly
• Gas manifold
• Combustion air inducer
• Gas valve
• Main burner cluster
•
Main burner orifices
• Pressure switch
• Ignitor
• Primary limit control
• Flame rollout switch
• Secondary limit