Haier FCD-HTHMG50-III(E), FCD-HTHMG60-III(E), FCD-HTHMG80-III(E),... Скачать руководство пользователя страница 6

KEEPING

SET

HEATING

SET

HEATING

ACTUAL

KEEPING

ACTUAL

Rated voltage: 230V~ , 50Hz                             Dimensions: (see to Fig. 1)

Power: 

 W                        Weight: (see to Fig. 1)

850 W /1300 W /2150

Rated pressure: 0.75 Mpa                                  Volume :(see to Fig. 1)

Waterproof grade: IPX 4 (  )                              Tap water pressure: not less than 0.05 MPa

Parameters

Setting Environment

² »

Ò ª

° ²

× °

Ó Ú

ΠÞ

· ¨

Å Å

Ë ®

µ Ä

µ Ø

· ½

Do not install it outdoors.

Do not install it as stand-alone.

It shall be hung on firm and solid wall.

Do not install it in places unable to drain
water.

Do not locate in freezing places. If ice 
forms, tank and pipes will break, causing 
scalding and leakage.

The tubes and pipes fitted on the product are inseparable parts of the

Safe Care

 

technology, and shall not be removed by yourself. Otherwise, Haier shall not be liable for 
any damages or injuries caused due to resulted potential risks.

If a drain hose is connected, it shall be 
connected to sewage drain, avoiding 
spilling the room.

Operation Instructions

Water heater automatically sets an energy saving temperature between 35

- 40

 

according to the difference between water temperature and ambient temperature 
(normally this medium temperature can ensure small demand but not shower. For shower, 
you need to quit Medium Warm mode, and press Mode button to enter Real-time Heating / 
Keeping mode.Then the water can be heated to the setting temperature in a short time.). 
When water temperature decreases to 34

, machine automatically restarts heating. 

Heating power level can be manually set with Power button.
    Example: Fig. 10 shows Medium Warm mode. Press Power button to set power level 
2150 W with corresponding indication lighted. The actual temperature then is 52

. When 

it decreases to 34

, machine will automatically re-heats to 40

 and keeps warm. It cycles 

in this way. In this mode, the machine defaulted highest heating temperature 40

 can't be 

adjusted.

(Fig.10)

(Fig.11)

7. 

Night Power Setting 

   With machine powered on, as described in Item 10, consecutively press Mode button 
until it enters Night Power operation mode (with Night Power indication on the display). If 
you would use hot water in early morning, you may adjust operation mode to Night Power 
mode. Machine will heat / warm in default period (0:00 on and 6:00 off). Heating power 
level and highest temperature can be manually set. In this mode, you can press Set button 
to calibrate clock time.
    In addition, in regional power consumption regulations, night power price rate is lower 
than in day, so Night Power mode will be easier and more economic. 
   Note: In selecting Night Power function, water heater clock shall be adjusted to local 
time. Inaccurate clock will cause night period partly charged as day use. (Only for 
regions with Peak and Valley Electricity Rates)
   Example: With machine powered on, press Mode button to select Night Power mode. 
When PC clock displays 00:00, machine automatically starts heating. It enters warm 
status after reaching setting value and has thermostat control during 0:00 

 6:00. (see 

Fig.11)

8. 

Intelligent Heating Function

   Intelligent heating function means that the system can analyze, process and memorize 
user's water use habits in one week, and accordingly heat water in advance automatically. 
With machine powered on, consecutively press Mode button until it enters Intelligent 
operation mode with intelligent indication lighted on. System automatically starts heating 
in the first memorized heating time since then. Heating power and highest temperature 
can be manually set. 
  In non-heating period, system remains standby with clock and intelligent indications 
lighted on. After it reaches the heating temperature, the machine will start to heat 
aotomatically. If you'd like to quit Intelligent Heating mode and enter another mode, you 
can press any button on control panel to activate the interface (buttons on remote 
controller inactive), and then press Mode button to shift modes.

Notes: 1. In any mode after powering on, Intelligent Heating function can memorize your 
water use habits. If you bathe in a fixed period everyday several times a week (4 times or 
more than 4 times), system will analyze and memorize your this habit and automatically 
start heating in advance.
2. Only in Intelligent mode can Intelligent function be executed. 

(Fig.12)

(Fig.13)

Never do that

Be sure to act as per instructions

Description of the Symbols

Содержание FCD-HTHMG50-III(E), FCD-HTHMG60-III(E), FCD-HTHMG80-III(E),...

Страница 1: ...ce Silver Sea ox Haier Household Electric Water Heater Rev 01 Specific Number 0040501638 Add Website http www haier com Haier Garden Qianwangang Road Economic Development Zone Qingdao P R China Group Qingdao Economic and Technological Development District Haier Water Heater Co Ltd ...

Страница 2: ...l of water or if components are damaged If sensor is damaged Corrective Measures Check Check and clean Re adjust Contact service station Continue heating Check Contact service station Contact service station Contact service station Fill water full or contact service station External Cleaning Disconnect power supply before cleaning Gently wipe with wet cloth dipped with a little of mild detergent D...

Страница 3: ...ower is 2150W and can t be adjusted Ppwer button With machine powered on press this button to shift heating power level between 850 W 1300 W and 2150 W or button Same as Adjust button on control panel If not in clock or delay time adjusting status you can use or button to increase or decrease temperature setting value between 35 75 with an increment 1 If in clock or delay time adjusting status the...

Страница 4: ...n activate interface by pressing any button on the control panel buttons on remote controller are inactive D Attentions in Operation To avoid causing machine troubles do not connect power before tank is full of water Adjust a suitable temperature before use for water temperature above 50 may burn your skin This product is closed water heater which can supply hot water through pipe connection to se...

Страница 5: ...indication and symbol lighted Press Set button to enter Time 1 hour setting status with Time 1 hour digits flashing Press or button to get 10 00 While hour digits are flashing you can press Set button to confirm and enter Time 1 minute setting Adjust the value to 10 30 with or button Then you may press Set button to confirm current settings or wait 6 s after which machine automatically confirms an...

Страница 6: ...would use hot water in early morning you may adjust operation mode to Night Power mode Machine will heat warm in default period 0 00 on and 6 00 off Heating power level and highest temperature can be manually set In this mode you can press Set button to calibrate clock time In addition in regional power consumption regulations night power price rate is lower than in day so Night Power mode will be...

Страница 7: ...tting value until reaching setting temperature again It repeats in this way HEATING SET HEATING ACTUAL Fig 8 Fig 9 Example Fig 9 shows real time heat warm status with heating power 1300W and temperature setting 75 6 Medium Warm Setting With machine powered on as described in Item 10 press Mode button until it enters Medium Warm operation mode with Medium Warm indication on the display Fig 1 Remark...

Страница 8: ...r heater Insert wall rack onto the hooks and bolts Fit flat washers rear wires and nuts in turn onto the bolts see Fig 3 Tighten the nuts and check them firm Install accessories such as safety valve drain hose as shown in Fig 4 Use sealing compound to prevent water leakage Fig 2 L1 L2 Fig 3 To facilitate installation and removal it is suggested a G 1 2 movable nut is fitted at appropriate location...

Отзывы: