DIAGNOSTICS
Indicator Lamps
Water Heated (ESD310-311-312) Indicator glows only when the cycle pauses to heat water to a set temperature.
Washing or rinsing continues as the water is heated. Once water reaches the set temperature, the light goes off and
the cycle resumes.
Washing (ESD310-311-312) Indicator glows during the pre-wash and main wash periods.
Turbidity Sensor (ESD310-311-312) Indicator glows during the sensing part of the cycle. Washing continues during
the sensing.
Rinsing (ESD310-311-312) Indicator glows during the rise periods.
Drying (ESD310-311-312) Indictor glows during the drying cycle after the final rinse.
Clean Indicator glows when a wash cycle is complete and will remain ON until the door is opened.
Sanitized Indicator glows when the cycle has met sanitization conditions. The light will remain ON until the door is
opened.
Add Rinse Aid (ESD310-311-312) Indicates the Rinse Aid Dispenser is empty. The indicator glows while a cycle is running.
Содержание ESD 300 Series
Страница 16: ...MACHINE COMPARTMENT Door Hinge The door hinge uses a rope cable over rollers and a spring for tension ...
Страница 26: ...WASH PUMP SERVICE Remove Pump Retaining Locks 3 ...
Страница 27: ...PUMP BODY REMOVAL Remove Lower Spray Arm Grasp the spray arm on each side of the shield and snap upward ...
Страница 29: ...PUMP BODY REMOVAL Remove Water Distribution Arm Distribution Arm snaps over back channel 3 screws ...
Страница 31: ...PUMP BODY REMOVAL Lift large object pre filter out This process can also be done after pump module is removed ...
Страница 32: ...PUMP BODY REMOVAL Remove Pump Assembly from tank Twist slightly to the right lifting the right front first ...
Страница 34: ...PUMP MOTOR IMPELLER SEAL SERVICE Remove inner strainer impeller cover ...
Страница 58: ...DOOR VENT Test 1250 Ohms 100 ohms Replace as an assembly ...
Страница 64: ...DOOR TENSION Spring Rope Cable Routing Door Hinge ...
Страница 67: ...DIAGNOSTICS Control Panel ESD 310 311 312 ...
Страница 68: ...DIAGNOSTICS Control Panel ESD 310 311 312 ...
Страница 69: ...DIAGNOSTICS Control Panel ESD 310 311 312 ...
Страница 74: ...Drain pump motor Approx 26 ohms DIAGNOSTICS Drain Pump Motor ...
Страница 75: ...DIAGNOSTICS Wash Pump Motor Internal motor wiring Dual winding capacitor start motor ...
Страница 77: ...DIAGNOSTICS Thermistor water temperature sensor Dual winding capacitor start motor ...
Страница 78: ...DIAGNOSTICS Thermistor water temperature sensor Onboard diagnostics for the thermistor ...
Страница 87: ...DIAGNOSTICS Float Safety Switch Float Safety Switch is Normally Open Switch CLOSED in this position NC NO ...
Страница 88: ...DIAGNOSTICS Schematic 310 311 312 ...
Страница 89: ...DIAGNOSTICS Rapid Advance Test Procedure ...
Страница 93: ...THANK YOU http service haieramerica com ...