background image

Disconnect power supply before cleaning. Gently wipe with wet cloth dipped with a 
little mild detergent. Do not use gasoline or other solvents. Finally dry with a  dry cloth. 
Keep water heater dry.

To  ensure  high  working  efficiency,  heating  elements  and  tank  liner  of  water  heater 
shall be cleaned once every three years. Take care not to damage the protection layer 
on  heating  elements  and  tank  liner  surface.  According  to  the  local  water  quality, 
magnesium  rod  shall  be  periodically  replaced.  If  maintenance  is  needed,  please 
contact a local service station.

2

7

After installation, as the tank is empty in the first usage, be sure to open the tap water 
inlet valve and mixing valve. When the tank is filled with water, and the shower nozzle or 
other water outlet keeps the water output, please close the mixing valve, check if there 
is water leakage at each joint and plug the power.

Turn the knob as per the needed water temperature. The mark of the knob increases 
from water inlet temperature to 75

æthe heating temperature steplessly. The heating 

indicator will light on under heating mode. Generally, the knob should be set to the 
highest scale. The water heater can regulate the temperature automatically. The power 
will be switched off automatically when the set temperature is reached, and will be 
switched on automatically when the temperature drops to a certain level. As it continues 
heating, you can use hot water as well.

When the tap water inlet pressure arrives at or exceeds 0.80MPa, the drain hose of 
safety valve will discharge a large amount of water. It is due to extra high water 
pressure. Please contact the local after service agent for disposal.

In long-term out-of-use or maintenance of the heater, you can close the city water pipe 
valve and set the mixing valve to the highest water temperature rate after opening the 
safety valve handle. Move up the safety valve handle to drain the tank. To avoid injury, 
before the next use, it is suggested to first open hot water valve before switching on the 
water heater, exhaust gas possibly retained in the pipeline. In this case, no smoke or 
fire is permitted near the open valve. Carefully check and confirm all parts are in good 
condition.

水。

Usage

Usage

Cleaning and maintenance

Cleaning and maintenance

Rated voltage

         V           230               230               230   

Rated pressure

       MPa                        

Rated temperature

Dimension
Waterproof grade
Mixing factor
Tap water pressure
Average temperature 

of hot water outlet
Re-heating time 

(temperature rise 50

℃)

Diameter of power wire
Outlet rate of hot water
24h fixed COP

Volume

Power
Net weight

Rated frequency

      Hz          50                50                                  

50

0.80
2000

2000

2000

0.80

0.80

W

Kg

75                

8                

10                

IPX4                

No less than 0.05MPa

See to Figure 1

3×1.5                

3×1.5                

3×1.5                

75

10

15

IPX4

75

14

25

IPX4

L
mm

mm

S

/
/
/

/

%

2

Front view

Side view

b

Cutaway vie w

Rear vie w

d

e

Model

       a        b        c        d        e        

         

298

287

501

152

100

318

300

623

152

100

378

374

616

152

100

Remarks: The permitted error or limit of the above parameters is ±10%.

Remarks: The permitted error or limit of net weight above is ±10%.

Hot water outlet

Thermometer tube

Wall-mounting bracket

Cold water inlet

   C 

Tank

Heating element

Anode rod

Parameters

Dimensions

Parameters

Dimensions

a

c

E

A

B

D

C

G

F

(Figure 1)

ES10V-M1

ES15V-M1

ES25V-M1

See to Figure 1

See to Figure 1

No less than 0.05MPa No less than 0.05MPa

ES10V

-

M1

ES15V

-

M1

ES25V

-

M1

All manuals and user guides at all-guides.com

Отзывы: