background image

Service Manual                         

 

Model No:ES10V-M1

 

 

Chapter 5: Specifications and Circuit Diagram   

5-1. Specifications 

Rated 

voltage

 

Frequency

Power

 

Rated 

pressure

Waterproof 

grade

 

Tap water 

pressure

 

230V

 

50Hz 2000W

 

0.80MPa

IPX4

 

no less than 

0.05MPa

5-2. Circuit Diagram 

 
 
 
 

 

 

-8- 

 

 

-4- 

 

 
 

Chapter 6: 

Usage, 

Cleaning and Maintenance   

6-1. Usage 

1. After installation, as the tank is empty in the first usage, be sure to open the tap water inlet valve and 

mixing valve. When the tank is filled with water, and the shower nozzle or other water outlet keeps water 

outputting, please close the mixing valve, check if there's water leakage at each joint, and plug the power 

plug.  

2. Turn the knob as per the needed water temperature. The mark of knob increases from water inlet 

temperature to 75

. You can set heating temperature steplessly. The heating indicator will shine under 

heating mode. Generally the knob should be set to the highest scale. The water heater can regulate the 

temperature automatically. The power will be switched off automatically when the set temperature is 

reached, and will be switched on automatically when the temperature drops to certain level. As it 

continues heating, you can use hot water as well.   

When the tap water inlet pressure arrives or exceeds 0.80MPa, the drain hose of safety valve will 

discharge large amount of water. It is due to extra high water pressure. Please contact the after service for 

disposal.  

6-2. Cleaning and Maintenance 

6-2-1. Statement 

This water heater shall only be repaired and maintained by qualified servicemen. Improper maintenance 

may cause severe injury or damage. Before opening or repairing water heater, please do pull out the 

power plug. 

 

 

 

Содержание ES10V-M1

Страница 1: ...ings or cautions to advise non technical individuals of potential dangers in attempting to service a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death 2009 Haier electric Company Limi...

Страница 2: ...mensions 5 Chapter 3 Installation 5 3 1 Accessory parts 5 3 2 Installation 5 3 3 Connection and use of safety valve 6 3 4 Attentions in Installation 6 Chapter 4 Operation 7 4 1 Operation Instructions 7 4 2 Attentions in Operation 7 Chapter 5 Specifications and Circuit Diagram 8 5 1 Specifications 8 5 2 Circuit Diagram 8 Chapter 6 Usage Cleaning and Maintenance 8 6 1 Usage 8 6 2 Cleaning and Mainte...

Страница 3: ...e temperature of the pressure relief vent of the safety valve is high so it may scald your body 7 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should ...

Страница 4: ...erature Adjustable water temperature Adjusting range water inlet temperature 75 4 Multiple usage Enclosed structure capable of supplying water to multiple places like toilet kitchen etc Suitable for family enterprises service trades like beauty care on hot water supply not drinkable 5 Nice molding vertical type wall mounting design saving space The water heater you purchased is the improved model ...

Страница 5: ...oks Hang the ring of the extended connection line onto a hook and hang the wall rack see Figure 2 Install accessories such as safety valve drain hose as shown in Figure 3 Use sealing compound to prevent water leakage 3 To facilitate installation and removal it is suggested a G 1 2 movable nut be fitted at appropriate locations on inlet and outlet pipes respectively Find the location requiring hot ...

Страница 6: ...t open to the atmosphere Check safety valve once a month as follow move the small handle of safety valve if there s water flowing out safety valve is normal if there s no water flow please contact local after sales service station 4 The pressure relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked Fig 4 3 4 Attentions in Installation 1 City water i...

Страница 7: ...ches off the water heater when temperature reaches the setting value and switch on again when water temperature decreases to certain value 3 City water pressure 0 80 MPa will cause much water flowing out from safety valve pressure relief vent This is due to too high water pressure Please ask after sales service for correction 4 2 Attentions in Operation 1 To avoid causing machine troubles do not c...

Страница 8: ...nlet temperature to 75 You can set heating temperature steplessly The heating indicator will shine under heating mode Generally the knob should be set to the highest scale The water heater can regulate the temperature automatically The power will be switched off automatically when the set temperature is reached and will be switched on automatically when the temperature drops to certain level As it...

Страница 9: ...ry Do not use cleansers containing grinding agent e g toothpaste acids chemical solvents e g alcohol or polishers to clean 6 2 4 Internal Cleaning To ensure high working efficiency heating elements and tank liner of water heater shall be cleaned once in three years Take care not to damage protection layer on heating elements and tank liner inner surface According to different local water qualities...

Страница 10: ... 10 Sincere Forever Haier Group Haier Industrial Park No 1 Haier Road 266101 Qingdao China http www haier com Printed in China ...

Отзывы: