Maintenances Services and Trouble Shooting
Water supply trouble
Phenomenon: water cannot be drained
Check:
Whether drain pump N Whether drain pump N circuit is damaged
is working is electrified
Y Y
Whether pipeline N repair the Drain pump is broken
is OK pipeline
Y
Drain hose is too high
Water overflow trouble
Phenomenon: drain pump keep on working
Check:
Whether water is deposited Y Whether water flows out of N Bottom case
in the bottom case the water overflow conduit is leaking
N Y
Whether the water N change water check water supply N change the solenoid
overflow switch is OK overflow switch solenoid valve valve
Y Y
Program controller is broken check the water N change the water
level switch level switch
Y
Program controller is broken
- 22 -
Содержание DW12-AFM4
Страница 8: ...Safety Precaution Warning and cautions 4 Safety Precaution 8 ...
Страница 9: ...Safety Precuation 9 ...
Страница 11: ...Warning and Cautions 5 Weekly maintenance 11 ...
Страница 14: ...Parts and Functions 8 Parts and functions 14 ...
Страница 17: ...Parts and functions 17 ...
Страница 19: ...Program Diagram 10 Program Diagram 19 ...
Страница 24: ...Circuit Diagram 12 Circuit Diagram 24 CL 1 ...
Страница 25: ...Exploded View 13 Exploded View ...