background image

 

 

 

11

INSTALLATION AND ACCESSORY PARTS

 

Installation and Accessory Parts 

 

Food Storage Basket 

Your  Freezer  has  1  or  2  removable  basket.  It  allows  you  to  store  food  more 

accessibly or you can remove it if not needed. 

Defrosting and Draining The Freezer                       

·

Defrost  whenever  the  frost  becomes  5MM  thick.  Never  use  a  sharp  or 

metallic  instrument  to  remove  the  frost  as  it  may  damage  the  cooling 

coils.(A punctured coil will void the warranty) 

·

Turn the temperature control to 0 position and unplug the unit. For draining, 

place a tray beneath the outer drain plug. Pull out the drain dial and rotate it 

so that the arrow points down ward. This will let the water flow out into the 

tray.

 

·

Remove the drain  plug from the  inside  of the freezer.  Defrosting  usually 

takes a few hours. To defrost faster keep the freezer door open. When done, 

push  the  drain  dial  in  and  turn  the  arrow  to  the  up  position.  Re-plug  the 

drain  plug  inside  the  freezer  compartment.  Note:  monitor  the  container 

under the drain to avoid overflow. 

·

Wipe  the  interior  of  the  freezer  and  replace  the  electrical  plug  in  the 

electrical outlet. 

·

Rest the temperature control to the desired setting. 

 

PDF created with pdfFactory trial version 

www.pdffactory.com

Содержание BD-478A

Страница 1: ...foam cover for efficient Temperature preservation Adjustable thermostat Superior insulation Efficient defrosted storage Designed for cafeterias restaurants and hotels Haier Group Manual No BD 478A Edi...

Страница 2: ...ircuit Diagram 15 12 Maintenance Service and Trouble Shooting 1 System Troubleshooting 16 2 Common freezer problems 28 3 Service and technical requirements of R134a freezer 30 4 Application and mainte...

Страница 3: ...Code Illumination and Series Introduction B D A B C D A The first letter of FREEZER in Chinese spelling B The first letter of FREEZER in Chinese spelling C Capacity Unit litre D Improve Series Number...

Страница 4: ...ed storage Designed for cafeterias restaurants and hotels Low power consumption 20 less than the other similar freezers Imported high quality compressor and condenser large freezing capacity 1 5 times...

Страница 5: ...478 Power Supply V Hz 220V 50Hz 220V 50Hz Unit Dimension W D H 1420 715 810 1690 715 810 Unit Weight Kg 72 78 Box Dimensions W D H 1495 765 870 1765 765 870 Box Weight Kg 84 91 Container Quantity 40HC...

Страница 6: ...ower cord Always grasp the plug firmly and pull straight out from the outlet 4 Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a cord t...

Страница 7: ...designed for freestanding installation only 8 Do not operate your freezer in the presence of explosive fumes 9 Do not refreeze foods which have been thawed completely 10 Do not use any electrical devi...

Страница 8: ...ENSION Net Dimension H a L W H Model BD 388A BD 478A Unit Dimension W D H 1420 715 810 1690 715 810 Dimension Door open 1420 715 1470 1690 715 1470 PDF created with pdfFactory trial version www pdffac...

Страница 9: ...trong enough to support it fully loaded 3 When moving the freezer never tilt it more than a 45 degree angle This could damage the compressor and the sealed system 4 If the freezer is tilted let it sta...

Страница 10: ...this is a dangerous practice since it provides no effective grounding for the freezer and may result in shock hazard Install Limitations l Do not install your freezer in any location not properly insu...

Страница 11: ...freezer or experience an electrical outage allow 5 Minutes before plugging it back in Note If the freezer has been placed in a horizontal or tilted position for any period of time wait 24 hours before...

Страница 12: ...aining place a tray beneath the outer drain plug Pull out the drain dial and rotate it so that the arrow points down ward This will let the water flow out into the tray Remove the drain plug from the...

Страница 13: ...f direct cooling single system freezers belongs to the category of a single temperature and single control refrigerating system with only one evaporator and is controlled by a single temperature contr...

Страница 14: ...ng it back in Note If the freezer has been placed in a horizontal or tilted position for any period of time wait 24 hours before plugging the unit in Adjustable temperature dial Your freezer will auto...

Страница 15: ...arting the machine the thermostat will be closed the compressor will run When the temperature in the freezer is lower and reaches the value for closing the machine the thermostat will be open thus the...

Страница 16: ...meter The normal value is several Ohm to tens of ohm If the resistance is zero means that there is a short in the freezer circuit or there is a short caused by a bad compressor or fan motor The reason...

Страница 17: ...ge of motor connection terminals the connection terminals of fully enclosed compressor are made from high temperature soda glass sintered ceramics around the terminals are filled with a high polymer T...

Страница 18: ...it If there is leakage please make the connections again and leave a piece of insulation paper under the screw 5 Leakage of fan because of too high humidity of freezer environment or a bad fan control...

Страница 19: ...e refrigerant oil If there is leak there will be traces of oil at the leak points 12 1 4 Troubleshooting by sounds 1 When the freezer is working normal high pressure liquid refrigerant flows into the...

Страница 20: ...the condenser s temperature is low too and there is only a small part warm In summer the temperature is high and the temperature of condenser cover is high too and the whole condenser is warm 2 The t...

Страница 21: ...er decision should be made 12 1 6 System noise repair Normally there are two kinds of freezer noise one is the natural noise of compressor and fan and the other is the resonance noise or structural no...

Страница 22: ...oise please clear the obstacles around the fan or adjust fan blades 6 If the fan supporter is loose and noise is caused please tighten 12 1 7 Poor freezing effect analysis and solutions 1 Check the po...

Страница 23: ...nnot be sealed well Remove dirt and put on a little talcum powder 5 Frequent opening and extended opening of freezer door will reduce refrigeration ability 12 1 8 How to handle the seal bar for poor s...

Страница 24: ...or Compressor damage may occur 12 1 10 How to know there is problem with compressor motor It is easy to find out motor problem by checking the resistance of coil The method is to connect the terminal...

Страница 25: ...d stuffs in the freezer too much door opens too frequent and open time too long 4 The environment temperature is too high humidity too high airflow is impeded 5 The frost layer at the evaporator is to...

Страница 26: ...refrigerant again 2 Clean the capillary or change filter Frost at evaporator is not full 1 There is some leakage of refrigerant 2 There is dirt block but not serious 3 Refrigeration quantity of compre...

Страница 27: ...been mounted to position or changed during transportation Mount it again 12 1 12 Procedure for fan change 1 Switch off power and open the fan protection cover 2 Remove the fan bolts by using fork wre...

Страница 28: ...contact of plug and socket is not well or the voltage is too low The knob of temperature controller is set to off position 2 In side factors Electrical problem of freezer normally caused by connectio...

Страница 29: ...nection state for a long time and cannot be released in time at normal situation the motor starting coil will cut off in about 1s after starting This will make the coil temperature rising rapidly and...

Страница 30: ...ad The reason is that the insulation around the motor windings bad 12 3 Service and technical requirements of a R134a freezer 12 3 1 Refrigeration equipment requirements The compressor condenser evapo...

Страница 31: ...age occurs at low pressure end Check system pressure if the system has no pressure the freezer has to be scrapped and change with new one if there is pressure it is repairable 12 3 4 Changing procedur...

Страница 32: ...to wipe away welding powder and flux 11 Connect the electrical controlling unit of compressor 12 Mount and adjust temperature controller 13 Switch on power for test run check unit operation 12 3 5 Co...

Страница 33: ...es R134a as the refrigerant which is recognized internationally It has an ozonosphere depletion coefficient ODP 0 New climate type design commercial freezer uses wide temperature zone design At 38 100...

Страница 34: ...then you can put food in If food is put in too early it may get damaged as the temperature is still high 6 Do not over pack refrigerator 7 Place food by reasonable sorts try to power open door frequen...

Страница 35: ...ground connection for the freezer ground line is not allowed to connect to water pipe gas pipe etc 4 Once the freezer is cut off at least 5 minute must be waited for starting again otherwise the comp...

Страница 36: ...er or soap water non corrosive neutral detergent is available After cleaning please make it dry by using cloth so as to avoid rust 6 Please clean the condenser compressor in the cabin and dust proof e...

Страница 37: ...there is any damage 5 Check the power cord if there is any wear or damage please change 6 Take an avometer and check if the resistance of ground resistor is normal 7 Check the insulation by using if i...

Страница 38: ...er 8 Philip screwdriver 9 Needle nose pliers notch pliers sealing pliers 10 Hansen valve 11 Tube cutters 12 5 2 Notice for use R134a filling equipment can only be used specially for R134a refrigerant...

Страница 39: ...pment until really to proceed 2 Evacuation Connect recovery machine hoses to system fittings Switch on power Switch on motor Open all related valves Observe the pointer of vacuum meter when it is acce...

Страница 40: ...serve the unit operation Switch off power 12 6 Freezer noise 12 6 1 Freezer noise sources Freezer noise comes from the expanding with heat and contracting with cold of compressor evaporator or condens...

Страница 41: ...e sound The continuous buzz we heard is this kind of sound 2 When compressor is produced there must be clearance between components When freezer is running the existing of clearance will make some com...

Страница 42: ...tic sound a hermetically sealed motor is relatively small 12 6 3 How is the sound of water flowing generated Answer When liquid refrigerant is flowing especially through the evaporator there will soun...

Страница 43: ...d may occur at the following situations 1 Newly bought freezer the internal stress of materials has not been eliminated With time going on the stress of materials will disappear and it is less possibl...

Страница 44: ...ssor cannot be started or noise will increase after starting and the wear of crankshaft will increase too It is better that freezer doesn t stop use Sometimes newly bought freezer also has this charac...

Страница 45: ...freezer noise is made in national standard GB8059 1 87 family use freezer with the volume below 250L noise 52 dB A sound power level The noise at offices we stay everyday or other public places is muc...

Страница 46: ...d is the sound power level Under the measuring conditions stipulated in national standard measure the freezer noise at four points take the average of indicated reading at greater noise situation calc...

Страница 47: ...r and so their noises are different Even for same type freezers as the noise of compressors are different their differences to national standard 52dB A are not the same and the noises are different 12...

Страница 48: ...e previous reasons freezer makes sound at starting and stopping 12 6 15 Why sometimes noise at far distance is greater than at near distance Answer Because the transfer of freezer noise has relations...

Страница 49: ...of sound power level of freezer with the volume 250L and below measuring according to the stipulations in item 6 3 6 1 will not greater than 52dB A Sound power level noise of freezing freezer with fan...

Страница 50: ...measurement point 1 2 3 4 measure the sound level by sound level meter A weighted Take the greater readings and calculate the average value The arithmetic average value of these four points is taken a...

Страница 51: ...ation resistor cool state 5 electrical intensity 6 starting performance 7 ground resistor 8 sealing performance of refrigeration system 9 documents and accessories Spot tests for ex factory are 10 sto...

Страница 52: ...set to 0 5g of yearly leakage check every position of refrigeration system Leakage at any point shall not greater than 0 5g Leakage inspection instrument normally used includes H 25 of American GE pro...

Страница 53: ...ent is made in accordance with the stipulations The leakage current measured shall not exceed 1 5mA 12 8 2 6 Noise test This test is carried out at semi sound eliminating room The freezer is put to th...

Страница 54: ...he stipulated environment temperature the fluctuation range is 0 5K Within the range of 2m heights away from the test platform the vertical temperature gradient shall not exceed 2K m Table 6 1 Differe...

Страница 55: ...num resistor There are two types Put the platinum resistor directly into test pack M pack when measuring a Its temperature b Insert the platinum resistor into the center of four tin electroplated copp...

Страница 56: ...and let the freezer running continuously Record the time needed for storage temperature tm to reach tm max in accordance with table 13 3 cooling temperature tm to reach 14 and the time the freezing t...

Страница 57: ...est of storage temperature ice producing ability etc Table 6 3 Storage temperature of freezer Storage Cabin Climate type Climat e type Environme nt temp t1 t2 t3 tm max Cooling cabin Freezing cabin 10...

Страница 58: ...Marketing model BD 388A 478A Exploded View Edition 2005 12 01 CARTON USER MANAUL LIST OF PARTS Parts list PDF created with pdfFactory trial version www pdffactory com...

Страница 59: ...0 007 X BD 388A 1 0 189 0 189 X 12 0070810205 Outer cabinet BD 478A 1 0 189 0 189 X 13 0070201812 Insolution fill cap large BD 388A 478A 1 0 0 X 14 0070800197 Castor BD 388A 478A 6 0 168 0 200 15 0070...

Страница 60: ...010 Ground screw BD 388A 478A 4 0 0 X 44 0074090308 Fan BD 388A 478A 1 0 063 0 100 45 0071210004 Engine room cover BD 388A 478A 1 0 0 X 46 0072130038 Screw BD 388A 478A 1 0 0 X 47 0077010036 Screw BD...

Страница 61: ...e spare parts warehouse and should be marked with 3 possible damaged The spare part which is not often damaged like the easy damaged one and the customer may stock in the spare part warehouse accord w...