INDOOR UNIT CONTROLS and COMPONENTS
PAGE 16
ENGLISH
Terminal Block
Display
Ambient Temperature Sensor
Piping Temperature Sensor
The indoor unit terminal block receives electrical power from
the outdoor unit. There are 4 connections for electrical wires.
Terminals 1 and 2 are connected to terminals 1 and 2 of the
outdoor unit. This wiring supplies power to the indoor unit.
Terminal 3 is a communication wire. The indoor unit sends
indoor air temperature, coil temperature and temperature
setpoint information to the outdoor unit on this wire. If a
splice or break in this wire is present, the indoor unit will not
be able to communicate with the outdoor unit. The ERROR
CODE will be code E7.
The Room Ambient Temperature Sensor is a negative
coefficient thermistor that will decrease in resistance with
increases in room air temperature. The sensor is located on a
clip mounted to the surface of the indoor coil.
The sensor connects to the control board at Plug CN-6.
The indoor display has an infrared communication circuit that
receives operating commands from the remote control. This
display will indicate operating modes, error codes, indoor air
temperature, timer status and power status.
The Piping Temperature Sensor is a negative coefficient
thermistor that will decrease in resistance with increases in
coil temperature. The sensor is located in a socket soldered
to the surface of the indoor coil.
This sensor will monitor the temperature of the indoor coil
in both cooling and heating modes of operation. Should
abnormally cold or hot coil temperature be detected by this
sensor, the system will take steps to correct the condition or
report an error code.
The sensor connects to the control board at Plug CN-6.
Содержание AW09TE1VHA
Страница 2: ... This page intentionally left blank ...
Страница 6: ...INTRODUCTION PAGE 6 ...
Страница 18: ...REMOTE CONTROL FUNCTIONS PAGE 18 ...
Страница 19: ...REMOTE CONTROL FUNCTIONS PAGE 19 ENGLISH Remote Control Functions Table of Contents Remote Controller 20 ...
Страница 32: ...SEQUENCE OF OPERATION PAGE 32 ...
Страница 42: ...INSTALLATION PAGE 42 ENGLISH This page intentionally left blank ...
Страница 49: ...ERROR CODES PROBLEM SOLVING PAGE 49 ENGLISH Outdoor Display LED1 Flashes 6 Times Spare Parts Z Z G ...
Страница 57: ...REFERENCE INFORMATION PAGE 57 ENGLISH Outdoor Board Schematic 9 12K ...
Страница 58: ...REFERENCE INFORMATION PAGE 58 Outdoor Board Schematic Outdoor Board Schematic ENGLISH ...
Страница 62: ...REFERENCE INFORMATION PAGE 62 ENGLISH Indoor Board Schematic 09 12K ...