background image

CONTROLLER FEATURES & SETTINGS

PAGE 2

ENGLISH

3

8

6

19

4

17

18

14

13

10

9

7

5

16

2

15

11

12

1

1

 

Power Button

 

Press the ON/OFF 

 button on the remote control to start 

the unit.

2

 

TURBO/QUIET Button

 

The TURBO function is used for fast heating or cooling. 
Press the TURBO/QUIET 

 button once and the remote 

control will display the TURBO 

 icon on the bottom right 

side of the remote display and switch the unit to the TURBO 

function. 

The QUIET function may be used when silence is needed for 

fast rest or reading.  Press the TURBO/QUIET 

 button 

again to switch to QUIET mode and the remote control will 

display the QUIET 

 

icon on the bottom left side of the 

remote display. 

Press  the TURBO/QUIET 

 button a third time to cancel 

TURBO/QUIET and return to normal operation.

Note:

TURBO/QUIET modes are only available when the unit is un

-

der cooling or heating mode (not for auto or fan mode).

Running the unit in QUIET mode for a long period of time 
may cause the room temperature to not reach the set 

temperature. If this occurs, cancel QUIET mode and set the 

fan speed to a higher setting. 

3

 

COOL Button

 

In COOL mode, the unit operates in cooling. When FAN is 
set to AUTO, the air conditioner automatically adjusts the 

fan speed according to room temperature. The 

 will be 

displayed during COOL mode.

4

 

HEAT Button

 

In HEAT mode, warm air will blow out after a short period of 

the time due to cold-air prevention function. When FAN is 

set to AUTO, the air conditioner automatically adjusts the 

fan speed according to room temperature. The 

 will be 

displayed during HEAT mode.

5

 

DRY Button

 

DRY mode is used to reduce humidity. In DRY mode, when 
room temperature becomes lower than temp. s2°F, 
unit will run intermittently at LOW speed regardless of FAN 

setting. The 

 will be displayed during DRY mode.

6

 

Tempe/- Buttons

 

Temp + Every time the button is pressed, the temperature 

setting increases.

Temp - Every time the button is pressed, temperature 

setting decreases.

The operating temperature range is 60°F-86°F (16°C-30°C).

7

 

AUTO Button

 

Under the mode of auto operation, the air conditioner will 
automatically select Cool, Heat, or Fan operation according 

to set temperature. When FAN is set to AUTO the air condi-

tioner automatically adjusts the fan speed according to room 

temperature. The 

 will be displayed during AUTO mode.

8

 

FAN Button

 

Fan speed selection
Press the FAN 

 button. For each press, fan speed changes 

as follows:

Remote control:

LOW

MED

HI

AUTO

Display 

circulated

The air conditioner fan will run according to the displayed fan 

speed.

When FAN is set to AUTO, the air conditioner automatically 
adjusts the fan speed according to room temperature.

9

 

Louver SWING Button - Vertical

 

Remote Controller

Содержание AW07LC2VHA

Страница 1: ...as a burnt smell are found immediately power off the main switch and contact a licensed contractor Do not obstruct or cover the ventilation grille on the air conditioner Do not put fingers or any other things into the inlet outlet or swing louver Do not allow children to play with the air conditioner Children should never be allowed to sit on the outdoor unit Please read this manual before using t...

Страница 2: ...re The will be displayed during COOL mode 4 HEAT Button In HEAT mode warm air will blow out after a short period of the time due to cold air prevention function When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature The will be displayed during HEAT mode 5 DRY Button DRY mode is used to reduce humidity In DRY mode when room temperature becomes...

Страница 3: ... Once the desired length of time is selected for the unit to turn on press the CONFIRM CANCEL to confirm this setting The remote control display changes as follows BLANK TIMER ON TIMER OFF TIMER ON OFF TIMER OFF ON 0 5h 0 5h 0 5h 0 5h Cancel TIMER ON setting With a TIMER ON set press the CONFIRM CANEL button once to cancel the TIMER ON Turning the unit ON with the TIMER from it being OFF will look...

Страница 4: ...RA FUNCTION Button Function A Refresh air Feature not available on this series B A B Yard This will allow you to control two seperate units with a single remote control Note this feature would be setup at the time of installation by the contractor C Fan Mode Is indicated by the icon Only the fan will operate in this mode See section 8 FAN Button for changing the fan settings D Intelligent upward a...

Страница 5: ...of the display remain active after battery removal press the reset button Do not block the air inlet or outlet Close doors and windows during operation Wipe the air conditioner using a soft and dry cloth For serious stains use a neutral detergent diluted with water Wring the water out of the cloth before wiping down the unit Then wipe off the detergent completely During cooling operation prevent d...

Страница 6: ... If the airflow creating a loud noise during unit operation the air filter may be too dirty The system circulates smells from the indoor air such as the smell of furniture paint and or cigarettes During COOL or DRY operation indoor unit may blow out mist This is due to the sudden cooling of the indoor air In DRY mode when the room temperature becomes lower than the set temperature by 2 F the unit ...

Страница 7: ...nstallation 2 Damages in shipping 3 Defects other than manufacturing 4 Damages from misuse abuse accident alteration lack of proper care and maintenance or incorrect electrical voltage or current 5 Damages from other than household use 6 Damages from services performed by other than a licencensed HVAC technician THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCL...

Страница 8: ...Haier America Wayne NJ 07470 2015 Haier America Trading LLC Indoor Model AW09ES2VHA AW12ES2VHA AW18ES2VHA AW24ES2VHA AW07LC2VHA AW09LC2VHA AW12LC2VHA AW18LC2VHA Issued Date January 2015 www Haier com ...

Отзывы: