Operation

   Air Flow Direction Adjustment

AUTO

COOL

DRY

FAN

HEAT

2.Select operation mode

Press FAN button. For each press, fan speed 

follows:

Press MODE button. For each press, operation mode
changes as follows:

Remote controller:

Remote controller:

Press

button

Every time the button is pressed, temp.setting
increase 1

o

C,if kept depressed, it will increase

rapidly

Every time the button is pressed, temp.setting

decrease 1

o

C,if kept depressed, it will 

decrease  rapidly

Select a desired temperature.

4.Fan speed selection

3.Select temp.setting

Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.

1. Unit start

 Press ON/OFF on the remote controller, unit starts.

Base  Operation

Remote controller

Vertical flap

Pos.1 blank Pos.2

Pos.3

Pos.4

(Auto swing)

1.Status display of air flow

When restart after remote turning off, the remote 

         memorize the previous 

Move the vertical blade by a knob on air

to adjust left and right direction referring to Fig.

2.Left and right air flow adjustment(manual)

Cautions:

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur 

adjusted to left or 

It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY

otherwise, condensate water might occur.

conditioner

Emergency operation and test operation

at air outlet if all vertical louvers are 

right.

mode ,

controller will automatically

Note:

set swing position.

changes as

'

Operation

Mode

AUTO

Remote

Controller

Note

COOL

DRY

HEAT

FAN

In DRY mode , when room temperature becomes
lower than temp.2

o

C, unit will run 

intermittently at LOW speed regardless of FAN 

Under the mode of auto operation, air conditioner 

will automatically select Cool or Heat operation

according to room temperature

to AUTO the air conditioner automatically adjusts

temperature.

When FAN is set 

the fan speed according to room

In FAN operation mode , the unit will not operate in

COOL or HEAT mode  but only in  FAN mode ,
AUTO is not available in FAN mode. And temp.
setting is disabled. In FAN mode, sleep operation 

 setting.

is not available. 

AUTO

LO

MED

HI

ON/OFF

FAN

MODE

LOCK

RESET

SWING

TIMER

CLOCK

SET

SLEEP

POWER/SOFT

LIGHT

test operation

 switch

Pi

Pi

Emergency Operation:

Use this operation only when the remote controller is defective 
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation. 
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in 
the following modes:

    Room
temperature

Designated
temperature

Timer
mode

Fan

speed

Operation

mode

  Above 23

o

C

  Below 23

o

C

 

23

o

C

 26

o

C

No

AUTO

AUTO

COOL

HEAT

No

Pi

emergency

operation switch

It is impossible to change the settings of temp. and fan speed,It 
is also not possible to operate in timer or dry mode.

temperature is below 16

o

C, do not use it in the 

Test operation:

Use this switch in the test operation when the room

normal operation.

 your finger from the switch: the cooling

Continue to press the test operation 

switch for more than 5 seconds . After

 you hear the "Pi" sound twice,

release

Test operation switch is the same as emergency switch.

operation starts with the air flow speed "Hi".

Under this operation mode,the fan motor of indoor

unit will run in high speed.

In HEAT mode, warm air will blow out after a short 
period of the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically 
adjusts the fan speed according to room temperature.

Содержание AS18GS1ERA -

Страница 1: ...onditioner Keep this operation manual for future reference SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL 10 2 3 9 11 PARTS AND FUNCTIONS OPERATION MAINTENANCE TROUBLE SHOOTING CAUTIONS INDOOR UNIT INSTALLAION 5 Contents NO 0010535426 AS18GS1ERA AS24GS1ERA ...

Страница 2: ...r reference Please be subject to the actual produce purchased the above picture is just from your reference Air Purifying Filter inside Inlet 1 Inlet grille 2 Outlet 3 adjust left and right air flow Vertical blade 4 Display board Horizontal flap adjust up and down air flow Don t adjust it manually Emergency Switch 6 7 8 5 1 2 3 4 5 6 7 8 11 10 8 9 13 14 15 16 12 17 ON OFF FAN MODE SWING TIMER CLOC...

Страница 3: ...operation air conditioner will automatically select Cool or Heat operation according to room temperature to AUTO the air conditioner automatically adjusts temperature When FAN is set the fan speed according to room In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode sleep operation sett...

Страница 4: ...When TIMER function is set the quiet sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timing on if the two modes are set up at the same time either of their operation time is ended first the unit will stop automatically and the other mode will be cancelled When quiet sle...

Страница 5: ...e the system yourself the dismantling of the air EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS 1 1 2 kg R410A 2 kg 2 1 B C D F E kg A This product contains fluorinated greenhouse gases covered by the Kyoto Protocol Do not vent into the atmosphere Refrigerant type R410A GWP value 1975 GWP global warming potential Please fill in with indelible ink 1 the factory refrigerant charge of the product 2 t...

Страница 6: ...ing can be conne cted with the outdoor unit ƽ Place where cold air can be spread in a room entirely ƽ Place nearby a power receptacle with enough space around ƽ Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left ƽ In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluore sc...

Страница 7: ...ndoor Unit Rear piping Draw pipes and the drain hose then fasten them with the adhesive tape ƽ Left Left rear piping In case of left side piping cut away with a nipper the lid for left piping ƽ In case of left rear piping bend the pipes according to the piping direction to ƽ the mark of hole for left rear piping which is marked on heat insulation materials 1 Insert the drain hose into the dent of ...

Страница 8: ...Flare tool for R410A Conventional flare tool Clutch type clutch type Rigid type Wing nut type Imperial type A 0 0 5mm 1 0 1 5mm 1 5 2 0mm rth leakage breaker Lean Damage of flare Partial Too outside Correct Incorrect On Drainage It becomes high midway The gap with the ground is too small There is the bad smell from a ditch It waves The end is imm ersed in water Please install the drain hose so as to...

Страница 9: ...he right side of the indoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteria killing medium air purifying filter face out...

Страница 10: ...TION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at t...

Страница 11: ...Cautions 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver Do not allow children to play with the air conditioner case should children be allowed to sit on the outdoor unit The refrigerating circuit is leak proof 1 Appl...

Отзывы: