3. Install ornament panel on indoor unit.
As shown in Fig.7,match the position of swing
flap motor with that of the indoor unit piping hole ,
so that ormament panel can be placed on to
indoor unit.
Installation of ornament panel
Place the holding ring on swing flao motor side
teporarily on hooks of the indoor unit. (2 pcs)
Put the other two holding rings on the hooks at
both side of the indoor unit. (Care should be
taken not to push wiring of swing flap motor
into seals).
Screw in all 4 screws under holding ring for
about 15mm. (Pancl will rise).
Adjust the ornament panel as per Fig. 7 to
cover opening on the ceiling.
Tighten screws to redrce the thickness of seals
between ornament and indoor unit to 5-8mm.
If indoor unit is at horizontal level and water
drainage is smooth, then, indoor unit height
can be adjusted throrgh holes at corners of
ornament panel.
If screws are not tighten tight,
problems in Fig, 8 might occur.
Tighten screws properly.
If there are still space
after tightening of screws,
please readjust the height
of indoor unit.
(Refer to Fig. 9)
Leave no space. Fig. 9
Gas leakage.
Gas leakage
from roof.
Contamination
Mist exists and drop down.
Fig. 8
(2)
1
2
3
4
5
5 _ 8mm
3
2
2
1
4
Holding ring
Piping hole position
Swing flap motor
Fig. 7
Seal
Indoor unit
Ceiling material
Ornament panel
Hook
Caution
(3)Wiring on ornament panel
Connecting of wiring of the swing
flap motor on ornament panel. (2 places)
(Refer to Fit . 10)
If connecting is not made, error code
(A7) appears on remote controller. So,
make proper connecting.
Side of ornament panel
Fig. 10
Wiring diagram
Side of indoor unit
4. Installation of inlet grill and cover plate
Installation of inlet grill
Install in reversed order of
"Prepare ornament pandl".
Inlet grill can be adjusted into four directions by turning inlet grill. Inlet grill position can be adjusted as
per customers request.
(1)
When installing inlet grill, take care not to twist wiring of swing flap motor.
Part a of the pad
Swing flap motor
Fig. 5
-35-
Installation