background image

SAFETY  PRECAUTIONS

5

1. Applicable ambient temperature range:

The machine is adaptive in following situation

Cooling

Heating

Indoor

Indoor

Outdoor

Outdoor

Maximum:
Minimum:

Maximum:
Minimum:

Maximum:
Minimum:

Maximum:
Minimum:

D.B / W.B
D.B / W.B

D.B / W.B
D.B / W.B

D.B / W.B

D.B / W.B

D.B

D.B
D.B

32     / 23
18     / 14

-7     / -8

24     / 18

43

15

15

27

/ 26

2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent

    or a similar qualified person.

3. If the fuse on PC board is broken please change it with the type of  T. 3.15A /2500.

4. The wiring method should be in line with the local wiring standard.

5. The power cable and connecting cable are self-provided. The power cable should be

   5x5.0mm

2

 .The connecting cable should be 4x2.0mm

2

.

    All the cables shall have got the European authentication certificate. During installa-

    tion, when the connecting cables break off, it must be assured that the grouding wire is

    the last one to be broken off.

6. The breaker of the air conditioner should be all-pole switch; and the distance between its

    two contacts should be no less 3mm.

7. The indoor unit installation height is at least 2.5m.

Installation and maintenance must be meet the local installation and miantenance instructions and
should operate by the experienced special installation and maintenance technicians .itherwise  we
donít take any duty of  the units damage or injure to the person caused by improper operation.

NOTE!

1.The sharp edges and corners and coil surface have the danger to  injury ,should avoid of them;
2.Itís very danger to remove the units and power supply wire.because it can cause injury and death .
Cut off all the power supply before mintenance.

WARNING!

Содержание AD88NAHAAA

Страница 1: ...TION MANUAL No 0010575124 B DUCT TYPE AIR CONDITIONER AD88NAHAAA AU88NATAAA HDU 88H03 H Please read this manual carefully before installing and using the air conditioning unit Please keep this manual safe for future use ...

Страница 2: ... OF HEATING HOT KEEP 18 IS THE UNIT INSTALLED CORRECTLY 19 INSTALLATION MANUAL FOR WIRE CONTROLLER 20 21 INSTALLATION MANUAL FOR INDOOR UNIT 22 27 INSTALLATION MANUAL FOR ELECTRIC WIRING 28 31 SAFETY PRECAUTIONS 3 5 PARTS AND FUNCTIONS 6 8 CAUTIONS 2 INSTALLATION MANUAL FOR OUTDOOR UNIT 32 38 ...

Страница 3: ... an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag made of polyethylene and the polyethylene ...

Страница 4: ...cident by some improper handing Do not install nearby the place where may have leakage of flammable gas Depending on the place of installation a circuit breaker may be necessary Drain pipe should be arranged to provide a positive draining If the gas leakes and gathers around it may cause the fire Unless the circuit breaker is installed it could cause elecrical shocks Where strong winds may prevail...

Страница 5: ...y of such equip ment which generates steam condensed water may drip during cooling operation or it could cause a fault current or short circuit When operating the system simultaneously with a combustion apparatus indoor air must be ventilated frequently Check occasionally the support structure of the unit for any damageafter a use of long period of time Insufficient ventilation could cause an oxyg...

Страница 6: ...ll the cables shall have got the European authentication certificate During installa tion when the connecting cables break off it must be assured that the grouding wire is the last one to be broken off 6 The breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less 3mm 7 The indoor unit installation height is at least 2 5m Installation and...

Страница 7: ...PARTS AND FUNCTIONS 6 Indoor Unit Air outlet Air inlet Air inlet Duct Duct Drainpipe Air outlet Air inlet ...

Страница 8: ...to select TIMER ON TIMER OFF TIMER ON OFF TIME Used to set clock and timer setting Used for unit start and stop Power ON OFF MODE Used to select AUTO RUN COOL DRY HEAT and FAN operation FAN SPEED Used to select fan speed LO MID HI AUTO TEMP Used to select your desired temp SET Used to confirm Timer and Clock settings SLEEP Used to select sleep mode AM PM AM PM PARTS AND FUNCTIONS Operation AUTO SE...

Страница 9: ... button AM or PM flashes Press or to set correct time Each press will increase or decrease 1min If the button is kept depressed time will change quickly After time setting is confirmed press SET AM and PM stop flashing while clock starts working Operation OPERATING LAMP FAN SPEED TIMER ON FAN OPERATION SLEEP DRY HEAT COOL AUTO TIMER OFF CLOCK TEMP Remote control ...

Страница 10: ...play at FAN Press FAN button For each press fan speed changes as follows Unit will run at selected fan speed Wire controller can memorize settings in each operation mode To run it next time just select the operation mode and it will start with the previous setting No reselecting is needed TIMER ON OFF needs reselecting In FAN mode temp can t be set Hints For cooling only type no HEAT function AUTO...

Страница 11: ...uickly Recommendations Hints Wire controller can memorize each operation status When starting it next time just press ON OFF button and unit will run in previous status Press FAN button For each press fan speed changes as follows 4 Fan speed selection Unit runs at the speed displayed on LCD In HEAT mode warm air will blow out after a short period of time due to cold draft prevention function In DR...

Страница 12: ...y time the button is pressed time increases 10min If button is kept depressed time will change quickly Every time the button is pressed time decreases 10min If button is kept depressed time will change quickly Time will be shown on LCD It can be adjusted within 24hours 4 Confirming your setting After setting correct time press SET button to confirm ON or OFF stops flashing Time displayed Unit star...

Страница 13: ...e will change quickly Time will be shown on LCD It can be adjusted within 24hours AM refers to morning and PM to afternoon Time displayed Unit starts at Xhour X min After time setting press TIMER button to confirm ON stops blinking While OFF starts blinking 4 Time confirming for TIMER ON Follow the same procedures in Time setting for TIMER ON 6 Time confirming for TIMER OFF After time setting pres...

Страница 14: ...S SLEEP RUN STOPS 1 hr 1 hr 3 hrs about 3 hrs decrease 2 C decreases 2 C increase1 C SHUT DOWN SLEEP RUN STOPS Heat mode SLEEP RUN BEGINS SETTING T SHUT DOWN Cooling mode Comfortable Sleep Note In AUTO mode unit will run in SLEEP function according to the operation mode After setting SLEEP function it is forbidden to calibrate clock If the set sleep time does not reach 8 hours the unit will stop o...

Страница 15: ...he air conditioner will enter the state of power failure compensation Cancel Method Press the Sleeping button on the wire controller 10 times within 5 seconds and after the buzzer rings 2 timer the power failure compensation mode will be cancelled Notes When a power failure suddenly occurs during the air conditioner is working after the power failure compensation is set if the air conditioner will...

Страница 16: ...wind does not blow during heating operation Isn t it warming up page 9 When the air conditioner does not operate properly after you have checked the above mentioned items or when the following phenomenon is observed stop the operation of the air conditioner and contact your sales dealer The fuse or breaker often shuts down Water drops off during cooling operation There is a irregularity in operati...

Страница 17: ...itched into the FAN mode during cooling To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode Even if the operation switch is turned on cooling dehumidifying or heating is not operable for three minutes after the conditioner is stopped Because the protecting circuit is activated D...

Страница 18: ... Do not open the inlet grill until fan stops completely Fan will continue rotating for a while by the law of inertia after operation is being stopped CAUTION Pre Season Care See that there are no obstacles blocking the air inlet and air outlet of both indoor and outdoor units Make sure that the air filter is not dirty Cut in the power supply switch 12 hours before starting run Post Season Care Ope...

Страница 19: ...over to ordinary heating operation WARMING OPERATION Heat pump type warming Defrosting operation Atmospheric temperature and warming capacity Period of warm up With the heat pump type warming the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space is utilized When a room is warmed with a heat pump type air conditioner frost accumulates ...

Страница 20: ...ot spring area etc The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordina rily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is con siderably large For details consult your sales dealer The electric work must be burden on the authorized engineer with qualificatio...

Страница 21: ...tallation use 2 wood screws accessory 2 For recessed installation use 2 wood screws accessory Note Try as far as possible a flat surface for installation Don t use excessive force when tightening screws or lower part might got deformed PCB is mounted on lower part of wire controller be careful not to damage it Lower part of wire controller Upper part of wire controller ...

Страница 22: ...ze Shield wire 4 core refer to Hint 3 4 0 33mm2 Wire size Hint 1 Switch box and cord for wiring are not supplied 2 Don t touch PCB with hand Use shielede wires for telecommunication between wire controller and indoor unit indoor unit and outdoor unit Ground the shield on one side Otherwise misoperation because of noise may occur Lower part of wire controller A B C D Upper part of wire controller w...

Страница 23: ...ufficiently support heavy weight When strength is insufficient injury can result from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes etc Improper installations can result in accidents due to a violent falling over of the unit For electrical work please see that a licensed electrician executes the wor...

Страница 24: ...rape 2 Choose installation place 1 The chosen installation place should meet the following requirements and get the userís consent Place ensures ideal airflow distribution The passage of airflow has no obstacles When importing outside air it should be imported directly from outdoors if the pipe can not be extended it also can not be imported from top Place ensures enough space for maintenance The ...

Страница 25: ...om vibration For details please consult to the builder 3 Hanger bolts installation Use care of the piping direction when the unit is installed Hanging bolt M10 Hole in anchor Hole in plug Insert Concrete Use M10 screw bolt In order to bear the weight of the unit for existed ceiling using foundation screw bolt for new ceiling using burying embedded screw bolt burying screw bolt or spot supplied oth...

Страница 26: ...accessory Pipe cover small for insulation accessory Clamp accessory Adhesion For drain pipe use hard PVC general purpose pipe VP 25 I D 1 which can be purchased locally When connecting insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp Adhesive must not be used connection of the drain socket and drain hose accessory c 5 Drain Pip...

Страница 27: ...ert the drain hose directly into drainage where the gas with sulfur may be generated Backwater bend Because the drain spout is at the position which negative pressure may occur So with the rise of water level in the drain pan water leakage may occur In order to prevent water leakage we designed a backwater bend The structure of backwater bend should be able to be cleaned As the below figure shown ...

Страница 28: ... 1Pa m when the dimension of one side of the air duct is fixed as 250mm as shown below Note 1Pa m 0 1mmAg m The chosen chart of simple duct m 3 h m 3 n 100 200 300 400 500 600 10 800 1 000 1 200 20 250 x 60 mmxmm 250 x 90 250 x 120 250 x 140 250 x 170 250 x 190 250 x 230 250 x 270 250 x 310 Shape Item Air volume Square duct Dimension m 3 h m 3 n 1 400 1 600 1 800 30 2000 2400 3 000 50 3 500 4 000 ...

Страница 29: ...eiling inner side instead The result is because of the irregular outer air mass strong wind and sunshine the humidity is increased There may be water drop on the outside of duct For cement and other new constructions even if not taking ceiling inner side as duct the humidity will also be so high At this time use glass fiber to perform heat preservation to the whole use iron net to bind the glass f...

Страница 30: ...apacity number of fan controller is set at ìNo 5î Rotate this switch capacity number setting No 1 No 8 Once the fan controller has trouble this linker can perform emergency assistant control When this linker is connected to the linker from the PCB it can operate with total load When this linker is connected to the linker from the PCB through the fan speed adjustment panel to adjust speed High Cond...

Страница 31: ...ht may damage nut leading to leakage Check if the connection pipe leaks then do heat insulation treatment as below figure shown Only use seal cushion to bind the joint part of air pipe and heat insulation parts Paste the refrigerant oil here Torque spanner Spanner Pipe joint Cone nut Middle size seal cushion accessory Use seal cushion to bind the pipe joint Clamp Heat insulation accessory for liqu...

Страница 32: ... type crimped terminal lugs with insulated grip on the ends of the wires Use copper conductor only Select wire sizes and circuit protection from table below This table shows 20 m length wires with less than 2 voltage drop 2 Wiring connection Make wiring to supply power to the outdoor unit so that the power for the indoor unit is supplied by terminals Item Model Phase Switch breaker A Circuit break...

Страница 33: ...late 2 When crane is used lift the unit with 4 pieces of steel rope with diameter above 6 mm 3 Put protective materials between the cable and the unit to prevent deformation and damage of the surface 2 Mounting 1 The distance between two connections must not beless than 20mm 1 During installation connect the outdoor unit and align the mounting surface See the figure on the right Mount the electric...

Страница 34: ...lation make sure that there is no refrigerant leakage Refrigerant if meeting with heaters and stoves ect in the room may produce hazardous gas Connection of refrigerant pipe 1 The joints of the refrigerant pipe are inside the unit Take off the access hole cover in front of the unit 2 The pipe can be connected from the front or bottom of the outdoor unit 3 Remove the L shaped pipe from the valve by...

Страница 35: ...oor unit Diag2 Outdoor unit is above the indoor unit Liuid check ring Accumulator set 1 per 6 meters 6 During welding the gas pipe valve must be cooled down with a wet cotton cloth During welding of the distribution pipe 1 In case of brazing weld of joint nitrogen must be filled in the pipe to prevent oxidization 2 The refrigerant pipe should be newly made and clean During installation do not let ...

Страница 36: ...e Nitrogen bottle VL VH Gauge distributor High pressure gauge Low pressure gauge Three way valve fully closed gas side Solder joint Solder joint Tightly closed Indoor unit Indoor Outdoor Access hole Copper pipe Solder joint Tightly closed Tightly closed Accesshole Outdoor unit Liquid side three way valve Leak Test Leak test must be made after connection of the refrigerant pipe according to the fol...

Страница 37: ...n 3 minutes under 1 5MPa 15kg cm2g Serious leakage may be found Step 3 Charge for more than 24 hours under 3 0MPa 3 0kg cm2g Small leakage may be found Check for pressure decrease Without pressure decrease Pass With pressure decrease Check for leaage There will be a 0 01MPa 0 1kg cm2g pressure change for every 1 C ambient temperature change during the 24 hour pressure charge It should be corrected...

Страница 38: ...tory charge the refrigerant not including the construction procedure charged parts The calculation of the refrigerant charging When the connection pipe L 5 meters not need to add refrigerant If the connection pipe L 5 meters we need recharge the 115g refrigerant per add 1 meter That is the quantity of refrigerant charging L 5 115 g Refrigerant charge Refill refrigerant When the outdoor valve is sh...

Страница 39: ......

Страница 40: ......

Отзывы: