background image

12

1.  Safety precautions

WARNING

Please read these "Safety Precautions" first then accurately execute the installation work.

Though the precautionary points indicated herein are divided under two headings,

and                             , those points which are related to the strong possibility of an installation done in error

resulting in death or serious injury are listed in the                              section. However, there is also a

possibility of serious consequences in relationship to the points listed in the                           section as well.

In either case, important safety related information is indicated, so by all means, properly observe all that is

mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation

tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment,

based on the owner's manual.

Moreover, ask the customer to keep this sheet together with the owner's manual.

This system should be applied to places as office, restaurant, residence and the like. Application to inferior

environment such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor.

Defects from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations

can result in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned

countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration.

In regards to preparing this countermeasure, consult with the company from which you perchased the equipment,

and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold

concentration does occur, there is the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is

insufficient, injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons

and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit.

For electrical work, please see that a licensed electrician executes the work while following the safety standards

related to electrical equipment, and local regulations as well as the installation instructions, and that only

exclusive use circuits are used.

Insufficient power source circuit capacity and defective installation execution can be the cause of electric

shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted

to the terminal connection part, through properly securing it. Improper connection or securing can result in

heat generation or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation

can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the

designated refrigerant (R410A) within the refrigeration cycle.

Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by

this company can result in water leakage, electric shock, fire and refrigerant leakage.

 CAUTION

WARNING

WARNING

 CAUTION

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a

telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit.

Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate

it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior

items.

Installation Manual For Indoor Unit

Содержание AD282AHEAA

Страница 1: ...ITIONER AD282AHEAA AD362AHEAA AD482AHEAA AD602AHEAA AD282AHERA AD362AHERA AD482AHERA AD602AHERA Operation Instruction Manual Please read this operation manual before using the air conditioner Please keep this manual carefully and safely ...

Страница 2: ...intenance 9 For Preparation of Heating Hot Keep 10 Is The Unit Installed Correctly 11 Installation Manual For Indoor Unit 12 20 Installation Manual For Electric Wiring 21 Safety Precautions 3 5 Parts and Functions 6 Cautions 2 Trouble Shooting 22 23 ...

Страница 3: ... an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag made of polyethylene and the polyethylene ...

Страница 4: ...cident by some improper handing Do not install nearby the place where may have leakage of flammable gas Depending on the place of installation a circuit breaker may be necessary Drain pipe should be arranged to provide a positive draining If the gas leakes and gathers around it may cause the fire Unless the circuit breaker is installed it could cause elecrical shocks Where strong winds may prevail...

Страница 5: ...y of such equip ment which generates steam condensed water may drip during cooling operation or it could cause a fault current or short circuit When operating the system simultaneously with a combustion apparatus indoor air must be ventilated frequently Check occasionally the support structure of the unit for any damageafter a use of long period of time Insufficient ventilation could cause an oxyg...

Страница 6: ...ouding wire is the last one to be broken off 6 The breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less 3mm 7 The indoor unit installation height is at least 2 5m Safety Precautions outdoor ambient temp operation mode recommended fan speed 40 20 5 18 cooling cooling heating heating low high low high 8 In order to obtain the Unit s bes...

Страница 7: ...6 Indoor Unit Air outlet Air inlet Duct Duct Drainpipe Parts and Functions ...

Страница 8: ...acle exist at the air inlet or outlet Cooling is not sufficient Isn t sun shine invading direct Isn t any unexpected heating load generated Isn t the room much crowded Isn t the swing louver horizontal At HEATING mode If swing louver is horizontal the blow wind does not reach floor The wind does not blow during heating operation Isn t it warming up When the air conditioner does not operate properl...

Страница 9: ...he FAN mode during cooling To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode Even if the operation switch is turned on cooling dehumidifying or heating is not operable for three minutes after the conditioner is stopped Because the protecting circuit is activated During this ti...

Страница 10: ...g the air inlet and air outlet of both indoor and outdoor units Make sure that the air filter is not dirty Cut in the power supply switch 12 hours before starting run Post Season Care Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well Stop operation and turn off the power supply switch Electric power is consumed even the air conditioner is in stop ...

Страница 11: ...ARMING OPERATION Heat pump type warming Defrosting operation Atmospheric temperature and warming capacity Period of warm up With the heat pump type warming the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space is utilized When a room is warmed with a heat pump type air conditioner frost accumulates on the heat ex changer of outdoor un...

Страница 12: ...c The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordina rily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is con siderably large For details consult your sales dealer The electric work must be burden on the authorized engineer with qualification for electric wo...

Страница 13: ... can result from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes etc Improper installations can result in accidents due to a violent falling over of the unit For electrical work please see that a licensed electrician executes the work while following the safety standards related to electrical equipmen...

Страница 14: ...The chosen installation place should meet the following requirements and get the user s consent Place ensures ideal airflow distribution The passage of airflow has no obstacles When importing outside air it should be imported directly from outdoors if the pipe can not be extended it also can not be imported from top Place ensures enough space for maintenance The pipe length between indoor and outd...

Страница 15: ...utdoor unit connection wire of indoor unit so that after installation they can be immediately connected with outdoor unit Cut the opening on the ceiling Maybe it needs to strengthen the ceiling to keep the ceiling even and flat and prevent the ceiling from vibration For details please consult to the builder Use M10 screw bolt In order to bear the weight of the unit for existed ceiling using founda...

Страница 16: ...Main unit VP 25 joint field purchased Pipe cover large for insulation accessory VP 25 field purchased Pipe cover for insulation field purchased Drain hose accessory Pipe cover small for insulation accessory Clamp accessory Adhesion For drain pipe use hard PVC general purpose pipe VP 25 I D 1 which can be purchased locally When connecting insert a PVC pipe end securely into the drain socket before ...

Страница 17: ...inage where the gas with sulfur may be generated Backwater bend Because the drain spout is at the position which negative pressure may occur So with the rise of water level in the drain pan water leakage may occur In order to prevent water leakage we designed a backwater bend The structure of backwater bend should be able to be cleaned As the below figure shown use T type joint The backwater bend ...

Страница 18: ...riction impedance of the duct is 1Pa m when the dimension of one side of the air duct is fixed as 250mm as shown below Note 1Pa m 0 1mmAg m The chosen chart of simple duct m 3 h m 3 n 100 200 300 400 500 600 10 800 1 000 1 200 20 250 x 60 mmxmm 250 x 90 250 x 120 250 x 140 250 x 170 250 x 190 250 x 230 250 x 270 250 x 310 Shape Item Air volume Square duct Dimension m 3 h m 3 n 1 400 1 600 1 800 30...

Страница 19: ...ad The result is because of the irregular outer air mass strong wind and sunshine the humidity is increased There may be water drop on the outside of duct For cement and other new constructions even if not taking ceiling inner side as duct the humidity will also be so high At this time use glass fiber to perform heat preservation to the whole use iron net to bind the glass fiber Affected by the ca...

Страница 20: ...tory the capacity number of fan controller is set at No 5 Rotate this switch capacity number setting No 1 No 8 Once the fan controller has trouble this linker can perform emergency assistant control When this linker is connected to the linker from the PCB it can operate with total load When this linker is connected to the linker from the PCB through the fan speed adjustment panel to adjust speed H...

Страница 21: ... pipe leaks then do heat insulation treatment as below figure shown Only use seal cushion to bind the joint part of air pipe and heat insulation parts Paste the refrigerant oil here Torque spanner Spanner Pipe joint Cone nut Middle size seal cushion accessory Use seal cushion to bind the pipe joint Clamp Heat insulation accessory for liquid pipe for gas pipe Heat insulation accessory Gas pipe Liqu...

Страница 22: ...connection Make wiring to supply power to the outdoor unit so that the power for the indoor unit is supplied by terminals Item Model Phase 3 Switch breaker A Circuit breaker Overcurrent protector rated capacity A Power source wire size minimum mm2 30 20 2 5 Switch breaker A Earth leakage breaker Leak current mA 30 30 AD482AHEAA AD482AHERA AD602AHEAA AD602AHERA AD282AHEAA AD362AHEAA AD362AHERA AD48...

Страница 23: ... 2m continuously CT check abnormal 3 times in 30m Fault phase short of phase out of balance greatly High pressure switch acts 3 times in 30m Low pressure switch acts in normal running Communication abnormal for more than 4m continuously Communication abnormal for more than 4m continuously Float switch broken down for more than 25m continuously Outside signal broken down for more than 10s Sensor br...

Страница 24: ... more than 2m continuously CT check abnormal 3 times in 30m High pressure switch acts 3 times in 30m Fault phase short of phase out of balance greatly Communication abnormal for more than 4m continuously Communication abnormal for more than 4m continuously Float switch broken down for more than 25m continuously Outside signal broken down for more than 10s Sensor broken down or short circuit for mo...

Страница 25: ...HAIER GROUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266555 P R China Web Site http www haier com ...

Отзывы: