Installation procedure
Electric wiring
2.The wiring method of straight terminal
For those connection wires whose end are not orbicular terminals, their
wiring method is:
Loosen the connecting screw, insert the end of the wire directly into the terminal block,
and then tighten screw. Pull the wire outwards slightly to confirm it is held tightly.
3
.
Pressing method of connection wire:
After wiring, the connection wire must be
pressed with wire holding clamp. The wire
holding clamp should press on the out cover
of the connection wire. As the right figure
shown:
Note:
All the wires should be copper core wires.
The power cable of indoor unit should be equipped according to the operation
manual of indoor unit.
Before finishing vacuumizing the refrigerant pipe system, do not supply
power to indoor unit.
The connection of power cable should be complied with local wiring regulation.
The wiring method of orbicular terminal
Wiring method
1.The wiring method of orbicular terminal
For the connection wire which end is orbicular
terminal, its wiring method is as the right figure
shown. Dismantle the screw and put it through the
ring at the end of the connection wire, then connect
it to the terminal block and tighten the screw.
Note:
When connecting the indoor & outdoor wire, check the number of the
indoor & outdoor terminals, the terminals with the same number connected
together with one wire.
Incorrect wiring will damage the controller of the air conditioner or make
the unit work abnormally.
The connection type of power cord is Y connection. If the soft power
cord is damaged, to avoid risk, it must be replaced by the manufacturer
or theirspecific repair department or similar professional worker.
Connect wire between indoor & outdoor unit
According to the wiring diagram in the manual of the outdoor unit to
perform wiring work.
Note: The marks on the terminals of the end of the connection wire should be corresponding
one by one.
28
(Sketch map)
Correct pressing
Terminal block
Wire holding clamp
Wrong pressing