Haier AD182AMEAA Скачать руководство пользователя страница 4

Safety Precautions

Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system.

Safety precautions described here are classified to "     WARNING" and "      CAUTION". Precautions which are shown in the column of

"      WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions

are shown in the column of "     CAUTION", a very serious problem could occur depending on situation. Make sure to observe these safety

precautions faithfully because they are very important information to ensure the safety.
Symbols which appear frequently in the text have following meanings.

Strictly prohibited.

Observe instructions faithfully.

Provide a positive grounding.

When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make sure to hand over

this manual to the new operator.

ON

OFF

WARNING

CAUTION

WARNING

CAUTION

CAUTIONS FOR INSTALLATION

The system should be applied to places as
office, restaurant, residence and the like.

The system should be installed by your
dealer or a professional installer.

When you need some optional devices such as a hu-

midifier, electric heater, etc., be sure to use the products

which are recommended by us. These devices should

be attached by a professional installer.

Application to inferior environment such as an engi-
neering shop, could cause equipment malfunction and
serious injury or death.

Installation by yourself is not encouraged because

it could cause such problems as water leakage,

electrical shock or fire accident by some improper

handing.

Installation by yourself is not encouraged because it

could cause such problems as water leakage, electrical

shock or fire accident by some improper handing.

Do not install nearby the place where may
have leakage of flammable gas.

Depending on the place of installation, a
circuit breaker may be necessary.

Drain pipe should be arranged to provide a
positive draining.

If the gas leakes and gathers around, it may cause the
fire.

Unless the circuit breaker is installed, it could
cause elecrical shocks.

Where strong winds may prevail, the
system should be fixed securely to prevent
a collapse.

Install on the place where can endure
the weight of air conditioner.

Make sure the system is grounded.

If the pipe is arranged improperly, furniture or the
likes may be damaged by leaked water.

Bodily injury could result by a collapse.

Bodily injury could result by a careless installation.

Grounding cable should never be connected to a gas

pipe, city water pipe, lightning conductor rod or

grounding cable of telephone. If the grounding cable

is not set properly, it could cause electric shocks.

CAUTIONS FOR OPERATION

You should refrain from exposing your body
directly to cool wind for a long time.

Do not poke the air inlet or outlet with a
bar, etc.

When any abnormal condition (scorching smell or oth-

ers) is found, stop the operation immediately and turn

off the power switch. Then consult your dealer.

It could affect your physical condition or cause some
health problems.

Since the internal fan is operating with a high
speed, it could cause an injury.

If you continue the operation without removing the
cause, it could result in a trouble, electric shock or fire.

The system should never be used for any

other purposes than intended such as for

preservation of food, flora and fauna, pre-

cision deices or work of art.

Do not handle switches with a wet hand.

Combustion apparatus should not be placed

allowing a direct exposure to wind of air con-

ditioner.

Incomplete combustion could occur on the apparatus.

It could cause electric shocks.

It could cause deterioration of food or other problems.

3

Содержание AD182AMEAA

Страница 1: ...10577971 C DUCT TYPE AIR CONDITIONER AD182AMEAA AD242AMEAA AD282AMEAA AD362AMEAA AD482AMEAA AD242AMERA AD282AMERA AD362AMERA Please read this operation manual before using the air conditioner Please keep this manual carefully and safely ...

Страница 2: ...ction 7 8 Care and Maintenance 9 For Preparation of Heating Hot Keep 10 Is The Unit Installed Correctly 11 Installation Manual For Indoor Unit 12 18 Safety Precautions 3 5 Parts and Functions 6 Cautions 2 Trouble Shooting 19 20 ...

Страница 3: ... an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag made of polyethylene and the polyethylene ...

Страница 4: ...cident by some improper handing Do not install nearby the place where may have leakage of flammable gas Depending on the place of installation a circuit breaker may be necessary Drain pipe should be arranged to provide a positive draining If the gas leakes and gathers around it may cause the fire Unless the circuit breaker is installed it could cause elecrical shocks Where strong winds may prevail...

Страница 5: ...m is operated at the vicinity of such equip ment which generates steam condensed water may drip during cooling operation or it could cause a fault current or short circuit When operating the system simultaneously with a combustion apparatus indoor air must be ventilated frequently Check occasionally the support structure of the unit for any damage after a use of long period of time Insufficient ve...

Страница 6: ...he connecting cable should be H05RN F 4G 0 75mm2 All the cables shall have got the European authentication certificate During installation when the connecting cables break off it must be assured that the grouding wire is the last one to be broken off 6 The power cable and connect cable should be self provided 7 The breaker of the air conditioner should be all pole switch and the distance between i...

Страница 7: ...Parts and Functions 6 Air outlet Air inlet Duct Air outlet Air inlet Duct For series 182 242 282 362 For series 482 ...

Страница 8: ... at the air inlet or outlet Cooling is not sufficient Isn t sun shine invading direct Isn t any unexpected heating load generated Isn t the room much crowded Isn t the swing louver horizontal At HEATING mode If swing louver is horizontal the blow wind does not reach floor The wind does not blow during heating operation Isn t it warming up When the air conditioner does not operate properly after yo...

Страница 9: ...he FAN mode during cooling To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode Even if the operation switch is turned on cooling dehumidifying or heating is not operable for three minutes after the conditioner is stopped Because the protecting circuit is activated During this ti...

Страница 10: ... no obstacles blocking the air inlet and air outlet of both indoor and outdoor units Make sure that the air filter is not dirty Cut in the power supply switch 12 hours before starting run Post Season Care Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well Stop operation and turn off the power supply switch Electric power is consumed even the air co...

Страница 11: ...over to ordinary heating operation WARMING OPERATION Heat pump type warming Defrosting operation Atmospheric temperature and warming capacity Period of warm up With the heat pump type warming the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space is utilized When a room is warmed with a heat pump type air conditioner frost accumulates ...

Страница 12: ...gas generates Hot spring area etc The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordina rily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is con siderably large For details consult your sales dealer The electric work must be burden on the authorized engineer wi...

Страница 13: ...When strength is insufficient injury can result from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes etc Improper installations can result in accidents due to a violent falling over of the unit For electrical work please see that a licensed electrician executes the work while following the safety stan...

Страница 14: ... part of your client user a Places where chilled or heated air circulates freely When the installation height exceeds 3m warmed air stays close to the ceiling In such cases suggest your client users to install air circulators b Places where perfect drainage can be prepared and sufficient drainage c Places free from air disturbances to the suction port and blowout hole of the indoor unit places whe...

Страница 15: ... Installation Manual For Indoor Unit For series 482 For series 182 242 282 362 3 Avoid installation and use at those places listed below a Places exposed to oil splashes or steam e g kitchens and machine plants Installation and use at such places incur deteriorations in the performance or corrosion with the heat exchanger or damage in molded synthetic resin parts b Places where corrosive gas such ...

Страница 16: ... drain pipe to unit pay suffcient attention not to apply excess force to the piping on the unit side Also fix the piping at a point as close as possible to the unit For drain pipe use hard PVC general purpose pipe VP 25 I D 1 which can be purchased locally When connecting insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp Adhesiv...

Страница 17: ... for the needed height is higher than 500 mm the back flow quantity of drain at the event of interruption of the operation gets too much and it may cause overflow at the drain pan Therefore make the height of the drain pipe within the distance given in the sketch below Avoid positioning the drain piping outlet at a place where generation of odor may be stimulated Do not lead the drain piping direc...

Страница 18: ... duct flange Conduct the duct installation work before finishing the ceiling 8 Connection of suction exhaust ducts a Duct connection position i Fresh air inlet Inlet can be selected from the side or rear faces depending on the working conditions Use the rear fresh air inlet when the simultaneous intake and exhaust is conducted Side inlet cannot be used ii Exhaust Make sure to use also the suction ...

Страница 19: ...Circuit breaker Overcurrent protector rated capacity A Power source wire size minimum mm2 Switch breaker A Earth leakage breaker Leak current mA Installation Manual For Indoor Unit 1 40 26 6 0 40 For series 282 362 30 30 20 2 5 30 3 For series 282 362 482 30 30 1 40 26 4 0 40 For series 242 2 Wiring connection For series 182 L N 1 2 3 Y G INDOOR UNIT TERMINAL BLOCK POWER 1PH 220 230V 50Hz SUPPLY Y...

Страница 20: ...sor broken down or short circuit for more than 2m continuously CT check abnormal 3 times in 30m Fault phase short of phase out of balance greatly High pressure switch acts 3 times in 30m Low pressure switch acts in normal running Communication abnormal for more than 4m continuously Communication abnormal for more than 4m continuously Float switch broken down for more than 25m continuously Outside ...

Страница 21: ...than 2m continuously CT check abnormal 3 times in 30m High pressure switch acts 3 times in 30m Fault phase short of phase out of balance greatly Communication abnormal for more than 4m continuously Communication abnormal for more than 4m continuously Float switch broken down for more than 25m continuously Outside signal broken down for more than 10s Sensor broken down or short circuit for more tha...

Страница 22: ...HAIER GROUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com ...

Отзывы: