9. Electric
data
9
.1 Wiring diagram
AD182ALERA
CIRCUIT DIAGRAM OF INDOOR UNIT
0010576547
(FREEZE)
CN8
SW2
BL
P13
(HUMI)
(PUMP)
(HEAT)
Y
(L)
(FRESH)
P8
P9
P7
P12
P10
P11
(COMM)
W
(N')
(M)
(H)
SW3
P17
(L')
P14 P15
SW5
SW4
P16
CN4
CN5
CN1
TRANS.
SWITCH
(DOOR)
(CONTROLLER)
WIRED
CONTROLLER
(FLOAT)
CN15
CN13
(UP-DOWN)
CN14
A
B
(ALARM)
CN16
(REMOTE)
CN11
CN12
FLOAT
REMOTE
RECEIVER
ON 12
ON 1234
CN19
UP-DN L-R
CN20
3
W:WHITE B:BLACK
R:RED Y:YELLOW
OR:ORANGE BL:BLUE
BR:BROWN
Y/G:YELLOW/GREEN
CAP.:FAN MOTOR CAPACITOR
TRANS.:TRANSFORMER
(RECEIVE
BOARD)
(SWING)
(OXYGEN)
OR
Y
Y
M
SWING
MOTOR
FAN MOTOR
2
12
1
5
8
9
7
CN21
CN7
FUSE
T3.15A/250VAC
P4(N2)
M
P5(N3)
TO OUTDOOR UNIT
R
2 3
1
B
W
W
R
B
W
B
OR
P1(L)
P2(N)
P3(N1)
MOTOR
MOTOR
SWING
PUMP
R
P6(N4)
SW1
(ROOM/PIPE)
CN6
TEMP.
SENSOR
SENSOR
PIPING TEMP.
ROOM
6
4
Y/G
Y/G
10
14
13
M
M
CAP.
Y/G
Y/G
M
11
CAP.
M
ON 1234
ON 1234
ON 1234
6. PARTS AND CONNECTED WIRES IN DASHED FRAME 12 13 ONLY AVAILABLE IN AC***AFBEA TYPE
7. REFER TO OPERATION MANUAL TO SET SW1-SW5
1. PARTS 1 2 3 IN DASHED FRAME ARE NOT AVAILABLE
2. PARTS 4 5 6 ARE OPTIONAL, AND THE LINE MARKED 14 ONLY AVAILABLE IN CONVERTIBLE TYPE
3. PARTS AND CONNECTED WIRES IN DASHED FRAME 7 9 ARE NOT AVAILABLE IN CONVERTIBLE TYPE,
AND CORRESPONDINGLY THERE IS A CLIP ON PCB
4. PARTS AND CONNECTED WIRES IN DASHED FRAME 8 ARE NOT AVAILABLE IN DUCT TYPE
5. PARTS AND CONNCETED WIRES IN DASHED FRAME 10 11 DETERMINED BY PRODUCTS TYPE
CN17
(12V/ALM)
NOTE:
REMOTE
CONTROLLER
CENTRALIZED
AD362AHERA
CIRCUIT DIAGRAM OF INDOOR UNIT
0010576548
(FREEZE)
CN8
SW2
BL
P13
(HUMI)
(PUMP)
(HEAT)
Y
(L)
(FRESH)
P8
P9
P7
P12
P10
P11
(COMM)
W
(N')
(M)
(H)
SW3
P17
(L')
P14
P15
SW5
SW4
P16
CN4
CN5
CN1
TRANS.
SWITCH
(DOOR)
(CONTROLLER)
WIRED
CONTROLLER
(FLOAT)
CN15
CN13
(UP-DOWN)
CN14
A
B
(ALARM)
CN16
(REMOTE)
CN11
CN12
FLOAT
REMOTE RECEIVER
REMOTE
ON 12
ON 1234
CN19 CN20
4
W:WHITE B:BLACK
R:RED Y:YELLOW
OR:ORANGE BL:BLUE
BR:BROWN
Y/G:YELLOW/GREEN
CAP.:FAN MOTOR CAPACITOR
FC:FAN MOTOR SPEED
CONTROLLER
TRANS.:TRANSFORMER
CONTROLLER
CENTRALIZED
(RECEIVE BOARD)
(SWING)
(OXYGEN)
3
1
10
FC
CN21
CN7
FUSE
T3.15A/250VAC
P4(N2)
TO OUTDOOR UNIT
P5(N3)
R
2 3
1
B
W
W
R
B
W
B
P1(L)
P2(N)
P3(N1)
R
P6(N4)
SW1
(ROOM/PIPE)
CN6
TEMP.
SENSOR
SENSOR
PIPING TEMP.
ROOM
8
6
Y/G
Y/G
9
2
CAP.
Y/G
M
ON 1234
ON 1234
ON 1234
5. REFER TO OPERATION MANUAL TO SET SW1-SW5
1. PARTS 1 2 3 4 5 IN DASHED FRAME ARE NOT AVAILABLE
2.PARTS 6 7 8 ARE OPTIONAL
3. PART 9 IS FAN MOTOR SPEED CONTROLLER KIT
4. PARTS 10 AND CONNECTED DASHED LINES ONLY AVAILABLE IN AD88NAHBEA
5
COM
NO
NC
COM
NO
NC
COM
8
6
4
2
5
3
1
7
8
6
4
2
5
3
1
7
8
6
4
2
5
3
1
7
NO
NC
CAP.
Y/G
M
7
FAN MOTOR
FAN MOTOR
NOTE:
CN17
(12V/ALM)
Model: AD182ALERA AD362AHERA
Commercial Air Conditioner
34