background image

18

**?

ON

OFF

Air does not blow or the fan speed cannot be
changed during drying.

In DRY mode, when room temperature
becomes 2 C higher than temperature setting,
unit rill run intermittently at LO speed regardless
of FAN setting

During heating,indoor fan is still running even
unit is stopped.

To get ride of the excess heat, indoor fan will
continue running for a while after unit autom-
atically stops.

Water or vapor generated from the outdoor
unit during heating.

This happens when the frost accumulated on
the outdoor unit is removed (during defrosting
operation).

Defrosting operation

Please check the following things about your air conditioner before making a
service call.

Unit fails to start.

Is the power supply switch on ?

Power supply switch is not in
ON position.

Is city supply power normal ?

Is the earth leakage breaker
in action ?

Be sure to turn off the power
supply switch immediately and
contact the sales dealer.

Trouble Shooting

3

Main points of Operation

Operation of Air Conditioner

When the environmental humidity is great,
water maybe dripped from the air outlet in
cooling or drying mode.

3-minute Protection Function

If restart the unit immediately after stopping,
the compressor will start only 3 minutes later
to protect the machine.

Variation of Fan Speed

If fan speed in auto mode, it will automatically
lower when the room temperature close to the
setting temperature in cooling mode.

In heating mode,the compressor stops when the
room temperature at setting temperature and fan
turns into low speed or stops.

In Dry mode,fan speed will be automatically varied.

Remote Control:

There is a telecommunication interface for remote control on the control
panel of the indoor unit. After the peripheral equipment have been installed
in accordance with the instruction manual of the selected remote control
detector, the air conditioner will be computerized and controlled from a far-
away place.

Содержание AB092FCAIA

Страница 1: ...OUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com Cautions Main Points of Operation Name of Each Part Safety Cautions Maintenance When Trouble Happens Customer Need to know Installation Procedures Trouble Shooting Installation Procedures Check and Test Run 1 2 3 4 5 6 7 8 9...

Страница 2: ... of an old air conditioner and contact your local authority or your dealer if you have any question Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting on an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner...

Страница 3: ...ipe cutter Expand flare after insert the pipe expander Installation check and test run Require customers to use air conditioner according to the operation manual The items checked during test run please mark in No gas leakage on the pipe joint How about the thermal insulation of the pipe joint Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly Is the wi...

Страница 4: ...ff the power supply switch immediately and contact the sales dealer Trouble Shooting 3 Main points of Operation Operation of Air Conditioner When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 3 minute Protection Function If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine Variat...

Страница 5: ...will not be used for a long time please cut off the power supply to prevent its operation from being resumed after the power is supplied again or press the ì Switch On Off î button after the power comes again Defrosting Running Wait a minute 17 The followings are not malfuncition Hua Hua Trouble Shooting Water flowing sound is heard When the air conditoner is started when the compressor starts or ...

Страница 6: ...st or deform the connecting pipe Do not mix dusts The bending radius shall be as large as possible Both gas pipe and liquid pipe shall be heat insulation No leakage in the flare 3 Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare The bending radius shall be as large as possible Align the pipe center when fastening and tighten the nut as shown in the figure...

Страница 7: ...cause the high speed fan is very dangerous and may cause injures The leaked refrigerant over certain density may cause oxygen deficient If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage When air conditioner is removed and reinstalled dealer should be responsible for them Incorrect installation ma...

Страница 8: ...s electrical shock without circuit breaker Not permitted when running 14 4 Installation of water drainage pipe 1 Install water drainage pipe Pipe diameter shall be equal or larger than that of connecting pipe Pipe of polythene size 25mm O D 32mm Drainpipe should be short with a downward slope at least 1 100 to prevent air bag from forming If downward slope of drainpipe cannot be made lifting pipe ...

Страница 9: ...pretared in the field Before going on installing adjust space to ceiling 3 Installation of indoor unit In case of no ceiling Install unit temporally Put suspending bracket on the suspending bolt to hang the unit up Be sure to use nut and washer at both end of the breaket to secure firmly After installation on the ceiling 1 Adjust unit to its right position Refer to preparation for installation 1 2...

Страница 10: ...oor and outdoor unit will not be blocked 4 Do not expose the unit to the place with heavy oil or moisture e g kitchen and workshop 5 Do not set the unit in the place where destructive gas such as sulfuric acid gas or pungent gas thinner and gasoline concentrates and retains 6 Place strong enough to support the unit weight 7 No expensive articles such as television and piano below indoor unit 8 Eno...

Страница 11: ......

Отзывы: