Smart Power

Содержание 1UH071N1ERG

Страница 1: ...SYJS 05 2018Rev D Edition 2018 05 Smart Power ...

Страница 2: ...tion 49 7 Sound Pressure Level 58 Part 4 Indoor Unit High ESP Duct Type 59 1 Feature 60 2 Specification 62 3 Dimension 68 4 Wiring Diagram 70 5 Airflow and Static Pressure Chart 72 6 Installation 75 7 Sound Pressure Level 87 Part 5 Outdoor Units 93 1 Specification 94 2 Dimension 103 3 Piping Diagram 106 4 Wiring Diagram 108 5 Noise Level 113 6 Outdoor Performace Curves 121 7 Installation 130 Part ...

Страница 3: ...1 Smart Power 1 Nomenclature 2 2 Line up 3 3 Feature 5 Part 1 General Information ...

Страница 4: ...00V 3PH 50 60Hz Inverter fixed speed A Fixed speed R Inverter Category E R410A Version 1 Version 1 Appearance character Cooling capacity 071 means 7 1kW Series H Smart portocol power inverter Type B Cassette D Duct U Outdoor unit Indoor outdoor unit A Indoor unit 1 1 1 Outdoor unit 2 1 2 Outdoor unit 1 Nomenclature ...

Страница 5: ...140K1ERG Medium Esp Duct ADH071M1ERG ADH071M3ERG ADH090M1ERG ADH105M1ERG ADH125M1ERG ADH140M1ERG High ESP Duct ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG ADH200H1ERG ADH250H1ERG Model Apperance Outdoor unit 1UH071N1ERG 1UH090N1ERG 1UH105N1ERG 1UH125P1ERG 1UH125P1ERK 1UH140P1ERK 1UH160P1ERG 1UH200W1ERK 1UH250W1ERK ...

Страница 6: ...4 Smart Power Model Apperance Panel 4 Way Cassette PB 950KB PB 950MB ...

Страница 7: ...l test panel All running parameters error code can be checked from 888 digital display installer can make easy work Wired controller data check Running parameters can be checked by controller if installer is not easy to go to the outdoor unit site just stay indoor to check installer can make easy work 3 Feature Double side 4 handles Because of double side 4 handles design it is very easy for 2 peo...

Страница 8: ...lock the panel Just one installer can finish the screwing for panel Save manpower and easy installation 4 way air flow Unique 360 air flow design New designed fan The diameter of new fan is enlarged based on acrodynamic theory so that there is the least resistance against airflow Reduce 3dB A for sound level Low Sound Level Super big inlet grille Compared to conventional air inlet grill we enlarge ...

Страница 9: ...er Part 2 Indoor Units 4 Way Cassette Type 1 Feature 8 2 Specification 9 3 Dimension 15 4 Wiring Diagram 16 5 Air Velocity and Temperature Distribution 17 6 Sound Pressure Level 21 7 Installation 24 8 Test run 30 ...

Страница 10: ...ter 10 years the panel color won t change to yellow color because the ABS material prevents discoloration against light raying New designed fan The diameter of new fan is enlarged based on acrodynamic theory so that there is the least resistance against airflow Reduce 3dB A for sound level Individual flap control The four flaps can be controlled individually according to end users by controller provi...

Страница 11: ...Net Shipping kg kg 31 36 Panel Model PB 950KB PB 950MB External dimensions W D H mm 950 950 50 Shipping dimensions W D H mm 1000 1000 110 Net weight Shipping weight kg 6 5 9 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid mm 9 52 Gas mm 15 88 Max pipe length without charge refrigerant m 20 Between I D O D MAX Drop m 30 MAX Piping length m 50 Connection method Flare...

Страница 12: ... 29 Weight Net Shipping kg kg 31 36 Panel Model PB 950KB PB 950MB External dimensions W D H mm 950 950 50 Shipping dimensions W D H mm 1000 1000 110 Net weight Shipping weight kg 6 5 9 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid mm 9 52 Gas mm 15 88 Max pipe length without charge refrigerant m 20 Between I D O D MAX Drop m 30 MAX Piping length m 50 Connection m...

Страница 13: ...eight Net Shipping kg kg 31 36 Panel Model PB 950KB PB 950MB External dimensions W D H mm 950 950 50 Shipping dimensions W D H mm 1000 1000 110 Net weight Shipping weight kg 6 5 9 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid mm 9 52 Gas mm 15 88 Max pipe length without charge refrigerant m 20 Between I D O D MAX Drop m 30 MAX Piping length m 50 Connection method...

Страница 14: ...rainage pipe material I D O D mm PVC 21 25 Controller O Optional S Standard Wired YR E17 O YR E16A O Infrared YR HBS01 S Fresh air hole dimension mm 75 Electricity heater kW Sound power noise level H dB A 64 Sound pressure noise level H M L dB A 48 45 52 Weight Net Shipping kg kg 40 45 Panel Model PB 950KB PB 950MB External dimensions W D H mm 950 950 50 Shipping dimensions W D H mm 1000 1000 110 ...

Страница 15: ...terial I D O D mm PVC 21 25 Controller O Optional S Standard Wired YR E17 O or YR E16A O Infrared YR HBS01 S Fresh air hole dimension mm 75 Electricity heater kW Sound power noise level H dB A 64 Sound pressure noise level H M L dB A 48 45 42 Weight Net Shipping kg kg 40 45 Panel Model PB 950KB PB 950MB External dimensions W D H mm 950 950 50 Shipping dimensions W D H mm 1000 1000 110 Net weight S...

Страница 16: ...ainage pipe material I D O D mm PVC 21 25 Controller O Optional S Standard Wired YR E17 O OR YR E16A O Infrared YR HBS01 S Fresh air hole dimension mm 75 Electricity heater kW Sound power noise level H M L dB A 64 Sound pressure noise level H M L dB A 48 45 42 Weight Net Shipping kg kg 32 38 Panel Model PB 950KB PB 950KB External dimensions W D H mm 950 950 50 Shipping dimensions W D H mm 1000 100...

Страница 17: ...15 Smart Power 3 Dimension ABH071H1ERG ABH090H1ERG ABH105H1ERG ABH125K1ERG ABH140K1ERG 288 168 840 59 47 765 765 765 840 59 765 246 47 950 950 950 950 ...

Страница 18: ...TROLLER M SENSOR TEMP ROOM ROOM CARD CN3 CN6 T5A 250VAC CN16 DRAIN PUMP M CN9 CN10 CN4 CN14 FUSE FLOAT SWITCH CN13 CN4 CN3 CN2 CN7 CN1 CN6 INTELLIGENT MOVE EYE DEVICE M M LOUVER STEP MOTOR4 LOUVER STEP MOTOR3 M M LOUVER STEP MOTOR2 LOUVER STEP MOTOR1 INDOOR UNIT MAIN CONTROL BOARD I R RECEIVER INFRARED REMOTE RECEIVER TEMP TEMPERATURE ON OFF ON CN26 AB M FRESH AIR MOTOR EXTERNAL ALARM OUTPUT FUNCT...

Страница 19: ...ty distribution Cooling Blowy angle 33 Air velocity distribution b Cooling Temperature distribution Cooling Blowy angle 33 Temperature distribution 2 5m s 2 5m s 1 5m s 1 5m s 0 5m s 2 7m 2m 2m 2m 1m 1m 1m 4m 3m 3m 4m 0m 0m 0 5m s 22 C 20 C 17 C 17 C 22 C 20 C 2 7m 2m 1m 0m 4m 3m 2m 1m 0m 1m 2m 3m 4m ...

Страница 20: ...gle 60 Air velocity distribution d Heating Temperature distribution Heating Blowy angle 60 Temperature distribution 2 7m 2m 1m 0m 3 0m s 3 0m s 2 0m s 2 0m s 1 0m s 2m 2m 1m 1m 4m 3m 3m 4m 0m 1 0m s 26 C 32 C 29 C 26 C 29 C 32 C 4m 3m 2m 2m 1m 1m 3m 4m 0m 2 7m 2m 1m 0m ...

Страница 21: ...wy angle 33 Air velocity distribution b Cooling Temperature distribution Cooling Blowy angle 33 Temperature distribution 2m 2m 1m 1m 4m 3m 3m 4m 0m 2 5m s 3 0m s 1 5m s 2 0m s 0 5m s 2 7m 2m 1m 0m 1 0m s 2 7m 23 C 21 C 18 C 23 C 21 C 18 C 4m 3m 2m 2m 1m 1m 3m 4m 0m 2m 1m 0m ...

Страница 22: ...gle 60 Air velocity distribution d Heating Temperature distribution Heating Blowy angle 60 Temperature distribution 2 7m 2m 1m 0m 3 5m s 3 5m s 2 5m s 2 5m s 1 5m s 2m 2m 1m 1m 3m 3m 4m 4m 0m 1 5m s 27 C 33 C 30 C 27 C 30 C 33 C 2 7m 2m 1m 0m 2m 2m 1m 1m 3m 3m 4m 4m 0m ...

Страница 23: ...ssure level DB 1 3 octave band frequency ABH071H1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low 0 10 20 30 40 50 60 Sound pressure level DB 1 3 octave band frequency ABH090H1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low ...

Страница 24: ...5H1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low 0 00 5 00 10 00 15 00 20 00 25 00 30 00 35 00 40 00 45 00 50 00 Sound pressure level DB 1 3 octave band frequency ABH125H1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low Fan high Fan med Fan low ...

Страница 25: ...10 00 15 00 20 00 25 00 30 00 35 00 40 00 45 00 50 00 Sound pressure level DB 1 3 octave band frequency ABH140K1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low Fan high Fan med Fan low ...

Страница 26: ...nstallation place is strong enough to hold weight Take necessary measures in case it is not safe Distance between holes are marked on paper pattern Refer to paper pattern for place need be reinforced 4 Selection of installation location of outdoor With consent from the user installation location shall Be sufficient to bear weight of the units with air circulation Avoid direct radiation from heat s...

Страница 27: ... decorative panel shall be 30mm or more The distance between indoor unit and ceiling shall be 20mm or less If it s more than 20mm add ceiling materials at or repair the ceiling 2 Complete all pipes for refrigerants and drainage and wires for connection of indoor and outdoor units to be connected to indoor unit before installation so that they can be connected to indoor unit immediately after insta...

Страница 28: ...on of condensate flow the float switch can not work normally and water leakage will be resulted 4 Pull out the original fixing plate that prevents the washer from dropping off and tighten nuts 5 Remove the installation cardboard 7 5 Installation of drain pipe 1 Install drain pipe Diameter of the drain pipe shall be greater than or equal to that of the connecting pipe PE pipe size I D 25mm O D 32mm...

Страница 29: ...e than 300mm away from the unit Note The slope of accessory drain pipe shall be within 75mm so that the drainage outlet does not necessarily bear excessive external force If multiple drain pipes join together install them as follows T joint confluent drain pipe The size of confluent drain pipe selected shall be suitable for operating capacity of the units 2 Check drainage is smooth after installat...

Страница 30: ...ove the air inlet grille as per the operation requirements 3 Installing the panel 1 Please remove the four 4 angle trim panels Removal method Flip the jack catches of the angle trim panel in the order of as shown in the following figure The flipping direction is indicated by the arrows Then the angle trim panel can be removed 2 Pull out the two 2 U shaped hooks on the indoor unit from below 3 Adju...

Страница 31: ... the trim panel Please keep the unit horizontal in the process of adjustment or else water leakage is easy to occur Please do not swing the louver blade by hand or else the blade mechanism would be damaged 6 Connection of trim panel Connect the black lead out terminal of the panel to the black lead out terminal of the indoor unit housing 7 When the installation of panel is complete please fix the ...

Страница 32: ...ing to the customer in accordance with the operation manual 1 Starting and stopping method operation switching temperature adjustment timer air flow switching and other remote control unit operations 2 Air filter removal and cleaning and how to use air louvers 3 Give the operation and installation manuals to the customer 8 2 Test run This unit will be started instantly without ON operation when el...

Страница 33: ... Smart Power Part 3 Indoor Units Medium ESP Duct Type 1 Feature 32 2 Specification 34 3 Dimension 41 4 Wiring Diagram 43 5 Airflow and Static Pressure Chart 46 6 Instalaltion 49 7 Sound Pressure Level 58 ...

Страница 34: ...air return or bottom air return is available 1 Feature 20 0 200 400 600 800 1000 40 60 80 100 40 35 25 20 0 200 400 600 800 1000 40 60 80 100 90 87 5 85 Torque kgfcm Rev r min AC motor efficiency DC motor efficiency Rev r min Torque kgfcm 120Pa 100Pa 70Pa 50Pa Air Flow 2500 2000 50po 70po 100po 120po ESP 1500 2500 100 m h 2500 100 m h 2500 100 m h 2500 100 m h 100 airflow when the ESP reach 120pa for H...

Страница 35: ... the wired controller it can optimise air duct work installation maintain airfiow and sound levels as required High lift up drain pump It can lift condensed water up to 750mm which make installation more flexible according to the layout Max 750mm H H M M L L External Statlc Pressure E S P E S P setting Pa 30 40 50 60 70 80 90 100 110 120 Air volume ...

Страница 36: ...h air hole dimension mm 145 Electricity heater kW Sound power noise level H dB A 58 Sound pressure noise level H M L dB A 38 35 32 Weight Net Shipping kg kg 31 2 36 8 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid m 9 52 Gas mm 15 88 Max pipe lengh without charge refrigerant mm 20 Between I D O D MAX Drop m 30 MAX Piping length m 50 Connecting method Flared Coolin...

Страница 37: ...ension mm 145 Electricity heater kW Sound power noise level H dB A 58 Sound pressure noise level H dB A 38 35 32 Weight Net Shipping kg kg 31 2 36 8 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid mm 9 52 Gas mm 15 88 Max pipe lengh without charge refrigerant 20 Between I D O D MAX Drop m 30 MAX Piping length m 50 Connecting method Flared Cooling Pdesignc kW 7 1kW ...

Страница 38: ...nsion mm 145 Electricity heater kW NONE Sound power noise level H dB A 60 Sound pressure noise level H M L dB A 40 37 34 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid mm 9 52 Gas mm 15 88 Max pipe lengh without charge refrigerant m 20 Between I D O D MAX Drop m 30 MAX Piping length m 50 Connecting method Flared Cooling Pdesignc kW 8 5kW SEER CLASS 6 1 A QCE Annua...

Страница 39: ...ctricity heater kW Sound power noise level H dB A 55 Sound pressure noise level H dB A 32 28 25 23 Weight Net Shipping kg kg 49 61 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid mm 9 52 Gas mm 15 88 Max pipe lengh without charge refrigerant 20 Between I D O D MAX Drop m 30 MAX Piping length m 50 Connecting method Flared Cooling Pdesignc kW 10kW SEER CLASS 6 7 A QC...

Страница 40: ...l L W H mm mm mm 1500 700 250 Package L W H mm mm mm 1710 865 320 Drainage pipe material I D O D mm PVC 26 32 Controller O Optional S Standard Wired YR E17 S YR E16A O Infrared YR HBS01 O Fresh air hole dimension mm 125 Electricity heater kW Sound power noise level H dB A 62 Sound pressure noise level H M L dB A 39 36 33 31 Weight Net Shipping kg kg 52 62 Piping Refrigerant Type Charge g R410A 370...

Страница 41: ...nal L W H mm mm mm 1500 700 250 Package L W H mm mm mm 1710 865 320 Drainage pipe material I D O D mm PVC 26 32 Controller O Optional S Standard Wired YR E17 S YR E16A O Infrared YR HBS01 O Fresh air hole dimension mm 125 Electricity heater kW Sound power noise level H dB A 62 Sound pressure noise level H M L dB A 39 36 33 31 Weight Net Shipping kg kg 52 62 Piping Refrigerant Type Charge g R410A 3...

Страница 42: ...on External L W H mm mm mm 1500 700 250 Package L W H mm mm mm 1710 865 320 Drainage pipe material I D O D mm PVC 26 32 Controller O Optional S Standard Wired YR E17 S YR E16A O Infrared YR HBS01 O Fresh air hole dimension mm 125 Electricity heater kW Sound power noise level H dB A 64 Sound pressure noise level H M L dB A 41 36 33 Weight Net Shipping kg kg 52 63 Piping Refrigerant Type Charge g R4...

Страница 43: ...41 Smart Power 3 Dimension 3 1 ADH071M1ERG ADH071M3ERG ADH090M1ERG air inlet air outlet ...

Страница 44: ...42 Smart Power 3 2 ADH105M1ERG AD1H125M1ERG ADH140M1ERG return air supply air ...

Страница 45: ...ET MUCH MORE DETAILS ABOUT THE STATIC PRESSURE LEVEL SELECTION OFF OFF SW1 4 SW1 5 SW1 6 OFF Static pressure OFF OFF ON TEMP SENSOR ROOM SENSOR PIPING TEMP ROOMCARD CN13 CN19 CN14 CH3 CN29 R O T O M N A F C D CN36 CN7 CN18 CN5 CN6 CN15 CN37 CN4 CH1 CH2 CN9 CN1 SW1 SW2 T5A 250VAC FUSE WIRED CONTROLLER FLOAT SWITCH WIFI CN8 CN22 CN23 PUMP TO OUT DOOR 2 1 3 B W R Y G ON ON ON ON 4th level 1st level R...

Страница 46: ...150523302 2 1 3 N L S B A C SW01 12345678 ON OFF FRESH AIR MOTOR SW01 6 select OFF EXTERNAL ALARM OUTPUT SW01 6 select ON Contact rating_230VAC 3A M CN21 Heater_L CH4 Heater_N CH2 CN5 CN4 CN34 CN16 CH1 SW01 1 SW01 2 SW01 3 ON SW01 4 SW01 5 SW01 6 SW01 7 SW01 8 MODEL OFF AM24LP2VHA OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON ADH071M3ERG OFF OFF ON CN13 CN6 CN41 CN22 CN22 1 4 SW03 5 SW03 08 IS USED FOR...

Страница 47: ...YL BLU ORG PNK GR WHT RD BLK RELAY FOR HEATER To outdoor unit Note 1 Dashed parts are op tional 2 E A O means external alarm output it is a function in future and CN7 is a 230VAC wet contact output 3 Once out of factorty do not change the DIP switches without technical guidence 4 SW2 is used for address setting on the situation of one wired controller control more than one indoor unit 5 Use wired ...

Страница 48: ...rt 500 600 700 800 900 1000 1100 1200 10pa 30Pa 50pa 70pa Air flow m3 h Static Pressure Pa Air flowand Static Pressure Chart ADH071M1ERG high med low 600 700 800 900 1000 1100 1200 1300 1400 10pa 30pa 50pa 70pa Air flow m3 h Airflow and Static Pressure Chart ADH090M1ERG H M L ...

Страница 49: ...ow m3 h Static Pressure Pa Airflow and Static Pressure Chart ADH105M1ERG High Speed Med Speed Low Speed 1000 1200 1400 1600 1800 2000 2200 2400 50 55 60 70 80 90 100 110 120 130 Air Flow m3 h Static Pressure Pa Airflow and Static Pressure Chart ADH125M1ERG High Speed Med Speed Low Speed ...

Страница 50: ...8 Smart Power 1000 1200 1400 1600 1800 2000 2200 2400 2600 50 55 60 70 80 90 100 110 120 130 Air Flow m3 h Static Pressure Pa Airflow and Static Pressure Chart ADH140M1ERG High Speed Med Speed Low Speed ...

Страница 51: ...must be assured that the grounding wire is the last one to be broken off 6 The power cable and connect cable should be self provided 7 The breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less than 3mm 8 The indoor unit installation height is at least 2 5m 9 A leakage breaker must be installed 10 10 1 FOR ADH071M1ERG ADH090M1ERG we can...

Страница 52: ...e infrared remote receiver RE 02 press HEALTH button 4 N times 1 N 10 integer within 12 seconds then the receiver will beep N 1 times the static pressure level N is been set successfully Note For Infrared remote controller YR HBS01 need press ON OFF button make the controller s at OFF status first then open the button cover press FRESH button will enter FAN mode interface Static pressure level N E...

Страница 53: ...t liquid side 1 For tightening the Connecting pipe 4 5 8 Brass nut gas side 1 5 Coupler heat insulation gas side 1 For indoor side pipe joint gas side 6 Coupler heat insulation liquid side 1 For indoor side pipe joint liquid side 7 Drain pipe 1 Drainage fittings group For ADHM series only 8 Instructions 1 Air conditioner operation 9 Cable tie Large 7 For fixing the heat insulation 10 Cable tie sma...

Страница 54: ...d the relative humidity is less than 80 When installing at a place under a high humidity environment pay sufficient attention to the prevention of dewing such as thermal insulation of the unit Installation dimension is the following Places exposed to oil splashes or steam e g kitchens and machine plants Installation and use at such places incur deteriorations in the performance or corrosion with t...

Страница 55: ... with the slot holes of hanging bracket Make adjustment so that the relation between the lower surface of the unit proper and water level in the hose becomes as given below a Adjust the out of levelness using a level or by the following method b Unless the adjustment to the levelness is made properly malfunctioning or failure of the float switch may occur ADH071M1ERG ADH071M3ERG ADH090M1ERG ADH105...

Страница 56: ...wavy form Central piping shall be laid out according to the right figure Take care not to apply external force onto the drain pipe connection part d For unit with water pump drain pipe use hard PVC general purpose pipe VP which can be purchased locally When connecting insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp Adhesive mu...

Страница 57: ...uch and it may cause overflow at the drain pan Therefore make the height of the drain pipe within the distance given in the sketch below g Avoid positioning the drain piping outlet at a place where generation of odor may be stimulated Do not lead the drain piping direct into a sewer from where sulfur gas may generate h Because the drain spout is at the position which negative pressure may occur So...

Страница 58: ...tatic pressure and select the length shape and blowout Note 1 Shield the central blowout hole for 2 spot 2 Shield the blowout hole around the center for 3 spot 2 spot 3 spot and 4 spot with φ 200 type duct are the standard specifications Inlet can be selected from the side or rear faces depending on the working conditions Use the rear fresh air inlet when the simultaneous intake and exhaust is con...

Страница 59: ...s use round type crimped terminal lugs with insulated grip on the ends of the wires Use copper conductor only Select wire sizes and circuit protection from table below This table shows 20 m length wires with less than 2 voltage drop Make wiring to supply power to the outdoor unit so that the power for the indoor unit is supplied by outdoor unit Outdoor 3 phase type Outdoor single phase type Phase ...

Страница 60: ... 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000 12500 16000 low speed med speed high speed low speed in cooling med speed in cooling high speed in cooling low speed in heating med speed in heating high speed in heating ADH090M1ERG ...

Страница 61: ...59 Smart Power Part 4 Indoor Unit High ESP Duct Type 1 Feature 60 2 Specification 62 3 Dimension 68 4 Wiring Diagram 70 5 Airflow and Static Pressure Chart 72 6 Installation 75 7 Sound Pressure Level 87 ...

Страница 62: ... requirement There are three side panel which can be opened for easy maintenance Top panel and bottom panel can be opened to maintain the fan and motor Electrical panel can be opened to maintain the electrical parts Side panel can be opened to maintain the pipe sensor Capacity Medium ESP duct airflow m3 h 10 0kW 12 5kW 14 0kW 2000 2250 2500 2880 3250 3600 44 44 44 High ESP duct airflow m3 h Promot...

Страница 63: ...n Download the smart air 2 app in IOS or android version you will have a remote control freely when you are out of home including weekly timer We use DC fan motor and wide fin more rows heat exchanger which can provide EER 3 4 for all high ESP duct combinations There are 4 speed airflow super low low medium high to choose for comfort There are also turbo mode with super high speed for quick coolin...

Страница 64: ... 210Pa Heat exchanger Type Diameter mm Inner grooved pipe φ7 0 Total area m2 0 45 Dimension External L W H mm mm mm 1350 490 425 Package L W H mm mm mm 1565 724 510 Drainage pipe material I D O D mm PVC Controller O Optional S Standard Wired YR E17 S Infrared YR HBS01 O Fresh air hole dimension mm Electricity heater kW 0 Sound power dB A 59 Sound pressure noise level H M L dB A 45 41 37 33 Weight ...

Страница 65: ...r mm Inner grooved pipe φ7 0 Total area m2 0 45 Dimension External L W H mm mm mm 1350 490 425 not including flange Package L W H mm mm mm 1565 724 510 Drainage pipe material I D O D mm none Controller O Optional S Standard Wired YR E17 S Infrared YR HBS01 O Fresh air hole dimension mm Electricity heater kW 0 Sound power dB A 61 Sound pressure noise level H M L dB A 47 44 42 39 Weight Net Shipping...

Страница 66: ... 37Pa 210Pa Inner grooved pipe φ7 0 Total area m2 0 45 Dimension External L W H mm mm mm 1350 490 425 Package L W H mm mm mm 1565 724 510 Drainage pipe material I D O D mm none Controller O Optional S Standard Wired YR E17 S Infrared YR HBS01 O Fresh air hole dimension mm Electricity heater kW 0 Sound power dB A 63 Sound pressure noise level H M L dB A 49 46 43 40 Weight Net Shipping kg kg 61 72 P...

Страница 67: ...nger Type Diameter mm Inner grooved pipe φ7 0 Total area m 0 45 Dimension External L W H mm mm mm 1350 490 425 Package L W H mm mm mm 1565 724 510 Drainage pipe material I D O D mm Controller O Optional S Standard Wired YR E17 S Infrared YR HBS01 O Fresh air hole dimension mm Electricity heater kW 0 Sound power noise level H M L dB A 67 Sound pressure noise level H M L dB A 51 47 45 42 Weight Net ...

Страница 68: ...00 Package L W H mm mm mm 1510 1037 568 Drainage pipe material I D O D mm Hot zinc plate 23 25 Controller O Optional S Standard Wired S YR E17 S OR YR E16A O Infrared O YR HBS01 Fresh air hole dimension mm Electricity heater kW NONE Sound power noise level H M L dB A 68 Sound pressure noise level H M L dB A 54 50 45 Pipe Liquid pipe mm 12 7 Gas pipe mm 19 05 Connecting method flared Weight Net Shi...

Страница 69: ...Package L W H mm mm mm 1510 1037 568 Drainage pipe material I D O D mm Hot zinc plate 23 25 Controller O Optional S Standard Wired S YR E17 S OR YR E16A O Infrared O YR HBS01 Fresh air hole dimension mm Electricity heater kW None Sound power noise level H M L dB A 69 Sound pressure noise level H M L dB A 55 51 47 Pipe Liquid pipe mm 12 7 Gas pipe mm 22 2 Connecting method flared or welding Weight ...

Страница 70: ...Smart Power 3 Dimension ADH105H1ERG ADH125H1ERG ADH140H1ERG 518 31 353 100 160 312 130 572 278 178 353 1163 1350 1285 1163 1052 271 320 64 320 64 312 425 234 1373 15 19 543 490 518 353 195 195 312 50 41 19 ...

Страница 71: ...69 Smart Power 20 500 298 298 1330 945 1221 890 377 959 1118 247 180 180 345 293 51 33 895 39 34 362 959 960 180 377 ADH200H1ERG ADH250H1ERG ...

Страница 72: ...he situation of one wired controller control more than one indoor unit 5 Use wired controller to select appropriate exter nal static pressure level 6 Refer to service manual to get more information about the static pressure level SW01 1 SW01 2 SW01 3 ON SW01 4 SW01 5 SW01 6 SW01 7 SW01 8 MODEL OFF OFF OFF OFF OFF ADH125H1ERG OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF ON ON ON ADH140H1ERG ADH105H...

Страница 73: ...OR HEATER 12V cont rol side To outdoor unit Note 1 Dashed parts are op tional 2 E A O means external alarm output it is a function in future and CN7 is a 230VAC wet contact output 3 Once out of factorty do not change the DIP switches without technical guidence 4 SW2 is used for address setting on the situation of one wired controller control more than one indoor unit 5 Use wired controller to sele...

Страница 74: ...essure Pa 37 50 60 80 100 120 150 170 190 210 H 3252 3217 3148 3165 3237 3418 3347 3286 3295 3090 M 2627 2852 2834 2823 2806 2995 2947 2963 2815 2635 L 2239 2263 2436 2394 2352 2455 2441 2374 2577 2415 SL 1780 1795 1788 1789 1760 1752 1748 1739 1735 1730 1000 1500 2000 2500 3000 37 50 60 80 100 120 150 170 190 210 Air flow m3 h Static pressure Pa Air flow and static pressure chart ADH105H1ERG H M ...

Страница 75: ...20 150 170 190 210 Air flow m3 h Static pressure Pa Airflow and Static PressureChart ADH140H1ERG H M L SL Static pressure Pa 37 50 60 80 100 120 150 170 190 210 H 3659 4 3588 3619 3634 3582 3774 3662 3546 3450 3025 M 3252 3217 3148 3165 3237 3418 3347 3286 3295 3090 L 2627 2852 2834 2823 2806 2995 2947 2963 2815 2635 SL 2239 2263 2436 2394 2352 2455 2441 2374 2577 2415 5 4 ADH160H1ERG 1500 2000 25...

Страница 76: ...30 5625 5500 5300 5154 4950 4730 4480 4240 High 5874 5811 5735 5621 5500 5301 5143 4858 4460 4080 3363 Med 6044 5973 5870 5748 5577 5300 4770 4372 3960 3520 2870 Low 5860 5800 5687 5550 5193 4885 4530 4180 3650 2990 2400 1000 2000 3000 4000 5000 6000 7000 62 72 90 110 130 150 170 190 210 230 250 Static pressure Pa Air Flow and Static Pressure Chart ADH200H1ERG Super high High Med Low Air flow m 3 ...

Страница 77: ...the cables shall have got the European authentication certificate During installation when the connecting cables break off it must be assured that the grounding wire is the last one to be broken off 6 The power cable and connect cable should be self provided 7 The breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less than 3mm 8 The ind...

Страница 78: ...utton 4 N times 1 N 10 integer within 12 seconds then the receiver will beep N 1 times the static pressure level N is been set successfully Note For Infrared remote controller YR HBS01 need press ON OFF button make the controller s at OFF status firstthen open the button cover press FRESH button will enter FAN mode interface Static pressure level N External static pressure pa ADH105H1ERG ADH125H1E...

Страница 79: ...o your local distributor WARNING Be sure to read these instructions carefully before beginning installation Failure to follow these instructions could cause serious injury or death equipment malfunction and or property damage Preparation of indoor unit Before or during the installation of the unit assemble necessary optional panel etc depending on the specific type Select places for installation s...

Страница 80: ... sulfurous acid gas or inflammable gas thinner gasoline etc in generated or remains Installation and use at such places cause corrosion in the heat exchanger and damage in molded synthetic resin parts c Places adjacent to equipment generating electromagnetic waves or high frequency waves such as in hospitals Generated noise may cause malfunctioning of the controller 1 Preparation for suspending th...

Страница 81: ...le to suspend the unit to the beam etc Directly by use of the bolts without using the hanger bolts Note When the dimensions of main unit and ceiling holes does not match it can be adjusted with the slot holes of hanging bracket Adjusting to the levelness a Adjust the out of levelness using a level or by the following method Make adjustment so that the relation between the lower surface of the unit...

Страница 82: ...water leaks Be sure to properly insulate the drain pipes The position of the installed drain pipe should have a downward gradient of 1 100 or more Do not connect the drain pipe in which ammonia or other types of gas affecting the unit is generated Unit model The size of drain opening ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG ADH200H1ERG ADH250H1ERG Φ25mm O D Please refer to the diagram and s...

Страница 83: ...ing shall be laid out according to the right figure Take care not to apply external force onto the drain pipe connection part d For unit with water pump drain pipe use hard PVC general purpose pipe VP which can be purchased locally When connecting insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp Adhesive must not be used for co...

Страница 84: ...on of odor may be stimulated Do not lead the drain piping direct into a sewer from where sulfur gas may generate h Because the drain spout is at the position which negative pressure may occur So with the rise of water level in the drain pan water leakage may occur In order to prevent water leakage we designed a backwater bend The structure of backwater bend should be able to be cleaned As the belo...

Страница 85: ...d to provide a trap for the safety drain pipe If the safety drain pipe is connected to the main drain pipe make the connection below the trap on the main drain pipe Make sure that drain pipe is installed without rises Do not perform air bleeding ...

Страница 86: ...tion work for air outlet ducts Calculate the draft and external static pressure and select the length shape and blowout Blowout duct 2 spot 3 spot and 4 spot with Φ 200 type duct are the standard specifications Note 1 Shield the central blowout hole for 2 spot 2 Shield the blowout hole around the center for 3 spot Limit the difference in length between spots at less than 2 1 Reduce the length of d...

Страница 87: ...s of the wires Use copper conductor only Selection of size of power supply and interconnecting wires Select wire sizes and circuit protection from table below This table shows 20 m length wires with less than 2 voltage drop Item Model Phase Circuit breaker Power source wire size minimum mm2 Earth leakage breaker Switch breaker A Overcurrent protector rated capacity A Switch breaker A Leak current ...

Страница 88: ...iring type Note When do the wired controller indoor PCB wiring work for model ADH071M3ERG do not connect the shielded wired to the unit s shell do not parallel wiring with strong electric lines within 0 3 meters please keep strong lines and the signal lines separately ...

Страница 89: ...ressure Level 7 1 ADH105H1ERG 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 Sound pressure level DB 1 3 octave band frequency ADH105H1ERG Sound pressure chart Cooling high Cooling med Cooling low Heating high Heating med Heating low ...

Страница 90: ...ower 7 2 ADH125H1ERG 0 0 10 0 20 0 30 0 40 0 50 0 60 0 Sound pressure level DB 1 3 octave band frequency ADH125H1ERG Sound pressure chart Cooling high Cooling med Cooling low Heating high Heating med Heating low ...

Страница 91: ...ower 7 3 ADH140H1ERG 0 0 10 0 20 0 30 0 40 0 50 0 60 0 Sound pressure level DB 1 3 octave band frequency ADH140H1ERG Sound pressure chart Cooling high Cooling med Cooling low Heating high Heating med Heating low ...

Страница 92: ...0 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000 12500 16000 20000 Sound pressure level DB 1 3 octave band frequency ADH160H1ERG Sound pressure chart Cooling high Cooling med Cooling low Cooling Silent Heating high Heating med Heating low Heating Silent ...

Страница 93: ...0 1 0 0 0 1 6 0 0 2 5 0 0 4 0 0 0 6 3 0 0 1 0 0 0 0 1 6 0 0 0 1 3 octave band frequency ADH200H1ERG Sound pressure chart fan low fan med fan high fan super high cooling low cooling med cooling high cooling super high heating low heating med heating high heating super high Sound pressure level DB ...

Страница 94: ...0 2 0 0 0 2 5 0 0 3 1 5 0 4 0 0 0 5 0 0 0 6 3 0 0 8 0 0 0 1 0 0 0 0 1 2 5 0 0 1 6 0 0 0 2 0 0 0 0 1 3 octave band frequency ADH250H1ERG Sound pressure chart fan low fan med fan high fan super high cooling low cooling med cooling high cooling super high heating low heating med heating high heating super high Sound pressure level DB 7 6 ADH250H1ERG ...

Страница 95: ...93 Smart Power Part 5 Outdoor Units 1 Specification 94 2 Dimension 103 3 Piping Diagram 106 4 Wiring Diagram 108 5 Noise Level 113 6 Outdoor Performace Curves 121 7 Installation 130 ...

Страница 96: ...m electronic expansion valve Defrosting Auto Volume of accumulator L 2 1 Sound power noise level H M L dB A 64 Sound pressure noise level H M L dB A 47 Type of four way valve SHF 4 10A Material of reduce noise Felt Crankcase heater power W Weight Net Shipping kg kg 80 92 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid mm 9 52 Gas mm 15 88 Connecting method Flared B...

Страница 97: ...tronic expansion valve Defrosting Auto Volume of accumulator L 2 1 Sound power noise level H M L dB A 66 Sound pressure noise level H M L dB A 50 Type of four way valve SHF 4 10A Material of reduce noise Felt Crankcase heater power W Weight Net Shipping kg kg 80 92 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid mm 9 52 Gas mm 15 88 Connecting method Flared Between...

Страница 98: ...tronic expansion valve Defrosting Auto Volume of accumulator L 2 1 Sound power noise level H M L dB A 68 Sound pressure noise level H M L dB A 52 Type of four way valve SHF 4 10A Material of reduce noise Felt Crankcase heater power W Weight Net Shipping kg kg 82 94 Piping Refrigerant Type Charge g R410A 2500 Recharge quantity g m 45 Pipe Liquid mm 9 52 Gas mm 15 88 Connecting method Flared Between...

Страница 99: ...l I D O D mm None Refrigerant control method mm mm ELECTRONIC VAVE 3 0mm Defrosting Auto Volume of accumulator L 4 0 Sound power noise level H M L dB A 69 Sound pressure noise level H M L dB A 52 Type of four way valve SHF 20D 46 Material of reduce noise XPE Crankcase heater power W 38 Weight Net Shipping kg kg 105 118 Piping Refrigerant Type Charge g R410A 3700 Maximum pipe length without recharg...

Страница 100: ... I D O D mm None Refrigerant control method mm mm ELECTRONIC VAVE 3 0mm Defrosting Auto Volume of accumulator L 4 0 Sound power Noise level H M L dB A 69 Sound pressure Noise level H M L dB A 52 Type of four way valve SHF 20D 46 Material of reduce noise XPE Crankcase heater power W 38 Weight Net Shipping kg kg 108 121 Piping Refrigerant Type Charge g R410A 3700 Maximum pipe length without recharge...

Страница 101: ... I D O D mm None Refrigerant control method mm mm ELECTRONIC VAVE 3 0mm Defrosting Auto Volume of accumulator L 4 0 Sound power Noise level H M L dB A 70 Sound pressure Noise level H M L dB A 53 Type of four way valve SHF 20D 46 Material of reduce noise XPE Crankcase heater power W 38 Weight Net Shipping kg kg 108 121 Piping Refrigerant Type Charge g R410A 3700 Maximum pipe length without recharge...

Страница 102: ...D mm None Refrigerant control method mm mm ELECTRONIC VAVE 3 0MM Defrosting Auto Volume of accumulator L 4 0 Sound power noise level H M L dB A 73 Sound pressure noise level H M L dB A 57 Type of Four way valve SHF 20D 46 material of reduce noise XPE crankcase heater power W 38 Weight Net Shipping kg kg 105 118 PIPING Refrigerant Type Charge g R410A 3700 Maximum pipe length without recharge refrig...

Страница 103: ... L 4 0 Sound power noise level H M L dB A 75 Sound pressure noise level H M L dB A 64 Type of four way valve SHF 35B 67 04 Material of reduce noise XPE Crankcase heater power W 38 Weight Net Shipping kg kg 160 175 Piping Refrigerant Type Charge g R410A 6350 Maximum pipe length without recharge refrigerant m 30 Recharge quantity g m 90 Pipe Liquid mm 12 7 Gas mm 19 05 Connecting method Flared Betwe...

Страница 104: ... L 4 0 Sound power noise level H M L dB A 75 Sound pressure noise level H M L dB A 64 Type of four way valve SHF 35B 67 04 material of reduce noise XPE crankcase heater power W 38 Weight Net Shipping kg kg 160 175 Piping Refrigerant Type Charge g R410A 6350 Maximum pipe length without recharge refrigerant m 30 Recharge quantity g m 90 Pipe Liquid mm 12 7 Gas mm 22 22 Connecting method Welding Betw...

Страница 105: ...103 Smart Power 2 Dimension 1UH71N1ERG 1UH90N1ERG 1UH105N1ERG 950 285 107 594 967 38 778 396 80 593 370 60 100 35 35 600 370 404 450 596 ...

Страница 106: ...104 Smart Power 1UH125P1ERG 1UH125P1ERK 1UH140P1ERK 1UH160P1ERG 950 1350 370 396 102 285 404 450 600 370 595 107 632 45 632 92 635 35 100 36 136 ...

Страница 107: ...105 Smart Power 1050 1636 30 400 468 650 200 200 31 Drainage hole I n s t a l l a t i o n h o l e 4 φ 1 5 D igital tube Stop valve Wire hole Pipe hole Pipe hole 1UH200W1ERK 1UH250W1ERK ...

Страница 108: ...ondensor middle temp sensor Tcm Evaporate Condensor Stop valve gas side 3 way stop valve liquid side 4 way stop valve Liquid gas segerator Filter Defrosting temp sensor Te Heater Indoor ambient temp sensor Tai Compressor Outdoor ambient temp sensor Tai Heating Cooling Heating Cooling Maintance valve 1UH71N1ERG 1UH90N1ERG 1UH105N1ERG 1UH125P1ERG 1UH125P1ERK 1UH140P1ERK 1UH160P1ERG ...

Страница 109: ... compressor 1 UH250W1ERK 1UH200W1ERK liquid pipe stop valve 4 way stop valve gas pipe stop valve Condensor upper high pressure switch heater Ts PMV condensor temp sensor Tcm silencer low pressure switch filter Tm indoor coil temp sensor Tai indoor ambient temp sensor Accumulator Te e c d s ...

Страница 110: ...se heater CHTR 4WV Tcm Td Te Ta TS TH Reserved 1UH140P1ERG Reserved Reserved 1UH140P1ERK 1UH125P1ERK SW7 ON 2 1 BLU blue BRN brown SW1 1 SW1 2 SW1 3 SW1 4 SW1 5 SW1 6 SW1 7 SW1 8 ON OFF Manually forced operation valid Manually forced operation invalid Manually forced cooling Manually forced heating low stand by power cost normal stand by cost unit as air conditi oner central control Refrigerant R4...

Страница 111: ...tom heater BHTR Crankcase heater CHTR 4WV Tcm Td Te Ta TS TH CENTRAL CONTROLLER BMS DEVICE Parameters monitor adaptor Hydro unit LP Reserved 1UH140P1ERG Reserved Reserved 1UH140P1ERK 1UH125P1ERK SW7 ON 2 1 BLU blue BRN brown 1 Dashed parts are optional marks are function in future 2 SW6 is used for central control adress selection refer to service manual to get more details 3 Once out of factory d...

Страница 112: ...OR LOWER MOTOR central control Tcm Temperature sensor of condenser s middle position Ts Compressor suction temperature sensor Te Defrost tempreature sensor Tao Outdoor unit ambient temperature sensor Td Compressor dischargetemperature sensor Th Temperature sensor of hot water optional E E V Electronic expansion valve LP Low pressure switch HP High pressure switch DERD Demand response enabling devi...

Страница 113: ...rankcase heater CHTR 4WV Tcm Td Te Ta TS TH CENTRAL CONTROLLER BMS DEVICE Parameters monitor adaptor Hydro unit LP Reserved 1UH140P1ERG Reserved 1UH160P1ERG 1UH140P1ERK 1UH125P1ERK SW7 ON 2 1 BLU blue BRN brown 1 Dashed parts are optional marks are function in future 2 SW6 is used for central control adress selection refer to service manual to get more details 3 Once out of factory do not change t...

Страница 114: ...perature sensor Td Compressor dischargetemperature sensor Tfin Temperature sensor of driver module s IPM E E V Electronic expansion valve LP Low pressure switch HP High pressure switch DERD Demand response enabling device Only used in Australia and New Zealand area BLK black WHT white RD red Y G yellow green Explanation of abbreviations 1 BLU blue 4WV Four way valve BMS Building Management System ...

Страница 115: ...00 20 00 25 00 30 00 35 00 40 00 45 00 50 00 Sound pressure level DB 1 3 octave band frequency 1UH071N1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low 1UH071N1ERG noise level 1 3 octave band frequency Sound pressure level DB ...

Страница 116: ...0 25 00 30 00 35 00 40 00 45 00 50 00 Sound pressure level DB 1 3 octave band frequency 1UH090N1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low 1UH090N1ERG noise level 1 3 octave band frequency Sound pressure level DB ...

Страница 117: ...315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000 12500 16000 20000 S ound pressure level DB 1 3 octave band frequency 1UH105N1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low 1UH105N1ERG noise level 1 3 octave band frequency Sound pressure level DB ...

Страница 118: ...00 30 00 40 00 50 00 60 00 Sound pressure level DB 1 3 octave band frequency 1UH125P1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low 1UH125P1ERG noise level 1 3 octave band frequency Sound pressure level DB ...

Страница 119: ...00 30 00 40 00 50 00 60 00 Sound pressure level DB 1 3 octave band frequency 1UH125P1ERK noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low 1UH125P1ERK noise level 1 3 octave band frequency Sound pressure level DB ...

Страница 120: ...00 30 00 40 00 50 00 60 00 Sound pressure level DB 1 3 octave band frequency 1UH140P1ERK noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low 1UH140P1ERK noise level 1 3 octave band frequency Sound pressure level DB ...

Страница 121: ...63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000 12500 16000 20000 Sound pressure level DB 1 3 octave band frequency 1UH160P1ERG noise level Cooling high Cooling med Cooling low Heating high Heating med Heating low ...

Страница 122: ... 6300 10000 16000 1 3 octave band frequency 1UH200W1ERK 1UH250W1ERK Sound pressure chart fan low fan med fan high fan super high cooling low cooling med cooling high cooling super high heating low heating med heating high heating super high Sound pressure level DB 1UH200W1ERK 1UH250W1ERK ...

Страница 123: ... 7500 8500 9500 16 10 18 12 20 14 5 21 15 22 16 24 17 26 18 Indoor WB DB 1UH071H1ERG performance curve in cooling 6 7 heating capacity 6 7 power input 6 7 COP 4 5 heating capacity 4 5 power input 4 5 COP 1 2 heating capacity 1 2 power input 1 2 COP 1 0 heating capacity 1 0 power input 1 0 COP 6 5 heating capacity 6 5 power input 6 5 COP 7 6 heating capacity 7 6 power input 7 6 COP 12 10 heating ca...

Страница 124: ...g capacity 7 6 power input 12 10 heating capacity 12 10 power input 16 15 heating capacity 16 15 power input 27 18 heating capacity 27 18 power input 1500 3500 5500 7500 9500 11500 13500 18 12 20 14 22 16 25 18 27 19 30 22 32 23 Indoor WB DB 1UH090N1ERG performance in curve in cooling 20 15 cooling capacity 20 15 power input 25 18 cooling capacity 25 18 power input 32 23 cooling capacity 32 23 pow...

Страница 125: ...r input 12 10 heating capacity 12 10 power input 16 15 heating capacity 16 15 power input 27 18 heating capacity 27 18 power input 1500 3500 5500 7500 9500 11500 13500 15500 18 12 20 14 22 16 25 18 27 19 30 22 32 23 Indoor WB DB 1UH105H1ERG performance curve in cooling 20 15 cooling capacity 20 15 power input 25 18 cooling capacity 25 18 power input 32 23 cooling capacity 32 23 power input 35 24 c...

Страница 126: ...heating capacity 7 6 power input 12 10 heating capacity 12 10 power input 16 15 heating capacity 16 15 power input heating capacity power input 1500 3500 5500 7500 9500 11500 13500 15500 17500 18 12 20 14 22 16 25 18 27 19 30 22 32 23 Indoor WB DB 1UH125P1ERG performancecurve in cooling 20 cooling capacity 20 power input 25 cooling capacity 25 power input 32 cooling capacity 32 power input 35 cool...

Страница 127: ...6 5 heating capacity 6 5 power input 7 6 heating capacity 7 6 power input 12 10 heating capacity 12 10 power input 16 15 heating capacity 16 15 power input heating capacity power input 1500 3500 5500 7500 9500 11500 13500 15500 17500 18 12 20 14 22 16 25 18 27 19 30 22 32 23 Indoor WB DB 1UH125P1ERK performance curve in cooling 20 cooling capacity 20 power input 25 cooling capacity 25 power input ...

Страница 128: ...ity 6 5 power input 7 6 heating capacity 7 6 power input 12 10 heating capacity 12 10 power input 16 15 heating capacity 16 15 power input 27 18 heating capacity 27 18power input 1500 3500 5500 7500 9500 11500 13500 15500 17500 18 12 20 14 22 16 25 18 27 19 30 22 32 23 Indoor WB DB 1UH140P1ERK performance curve in cooling 20 cooling capacity 20 power input 25 cooling capacity 25 power input 32 coo...

Страница 129: ...acity 5 3 power input 7 6 heating capacity 7 6 power input 10 8 heating capacity 10 8 power input 15 10 heating capacity 15 10 power input 20 15 heating capacity 20 15 power input 24 18 heating capacity 24 18 power input 3000 5000 7000 9000 11000 13000 15000 17000 19000 21000 18 12 21 15 23 16 25 18 27 19 29 21 32 23 Indoor WB DB 1UH160P1ERG performance curve in cooling 20 cooling capacity 20 powe...

Страница 130: ...acity 5 3 power input 7 6 heating capacity 7 6 power input 10 8 heating capacity 10 8 power input 15 10 heating capacity 15 10 power input 20 15 heating capacity 20 15 power input 24 18 heating capacity 24 18 power input 3000 8000 13000 18000 23000 28000 33000 18 12 21 15 23 16 25 18 27 19 29 21 32 23 Indoor WB DB 1UH200W1ERK performance curve in cooling 20 cooling capacity 20 power input 25 cooli...

Страница 131: ...00 9000 14000 19000 24000 29000 34000 16 10 18 12 20 14 5 22 16 24 17 Indoor WB DB 1UH250W1ERK performance curve in heating 15 16 heating capacity 15 16 power input 10 11 heating capacity 10 11 power input 5 7 heating capacity 5 7 power input 0 2 heating capacity 0 2 power input 5 3 heating capacity 5 3 power input 7 6 heating capacity 7 6 power input 10 8 heating capacity 10 8 power input 15 10 h...

Страница 132: ...n dry and tight Clean and dry Foreign materials including mineral oils or moisture should be prevented from getting mixed into the system Tight Read 9 Precautions on refrigerant piping on page 10 carefully and follow these procedures correctly Since R410A is a mixed refrigerant the required additional refrigerant must be charged in its liquid state If the refrigerant is in state of gas its composi...

Страница 133: ...alled level Places where there is no possibility of flammable gas or product leak The equipment is not intended for using in a potentially explosive atmosphere Places where servicing space can be well ensured Places where the indoor and outdoor unit s piping and wiring lengths come within the allowable ranges Places where water leaking from the unit cannot cause damage to the location e g in case ...

Страница 134: ... If you install the unit on a frame please install a waterproof plate field supply within 150mm of the underside of the unit in order to prevent the invasion of water from the lower direction When installing the unit in a place frequently exposed to snow pay special attention to elevate the foundation as high as possible Make sure that the unit is installed level 7 2 2 General When operating the o...

Страница 135: ...It is best to screw in the foundation bolts until their length are 20mm from the foundation surface Fix the outdoor unit to the foundation bolts using nuts with resin washers 1 as shown in the figure If the coating on the fastening area is stripped off the nuts rust easily Dimensions bottom view unit of measurement mm A leg pitch1 B leg pitch2 C Front grill air outlet side D Drain hole E Bottom fr...

Страница 136: ...nit installation unit mm The top and two side surfaces must be exposed to open space and barriers on at least one side of the front and back shall be lower than the outdoor unit 1UH200 1U250 OTHERS A 200 150 B 300 200 C 360 150 D 360 150 E 360 200 F 360 200 G 600 300 H 3000 1500 ...

Страница 137: ... properly In regions where buildups of snow can be expected the accumulation and freezing of snow in the space between the heat exchanger and external plate may lower operating efficiency After punching the knock out hole the application of repair type paint on the surface around the edge sections is recommended to prevent rust 7 4 Refrigerant pipe size and allowable pipe length DANGER NOTICE INFO...

Страница 138: ...ter larger than the conventional ones Flare nut Connecting the unit to piping Use Type 2 Flare nuts 2 Tools and materials that may be used with R410 with some restrictions Tools Materials Use Notes Gas leak detector Detection of gas leaks The ones for HFC type refrigerant may be used Vacuum pump Vacuum drying May be used if a reverse flow check adaptor is attached Flare tool Flare machining of pip...

Страница 139: ...ble to use type O for pipes with a size of up to 19 05 3 4 with conventional refrigerants use type 1 2H pipes for units that use R410A Type O pipes may be used if the pipe size is 19 05 and the radial thickness is 1 2t The table shows the standards in Japan Using this table as a reference choose pipes that meet the local standards Flare Machining type O and OL only The flare machining dimensions f...

Страница 140: ...ndicated in paragraph 7 5 2 Refrigerant pipe size on page 120 Piping length must be withinlimits of the allowable pipinglength as in paragraph 7 5 3 Allowable pipe length and height difference on page 120 Piping must be designed for R410A See paragraph 7 4 2 Selection of piping material on page118 2 Piping can be reused without cleaning when Total 1 way piping length 50m No compressor breakdown ha...

Страница 141: ...ipe ø15 88mm 1UH200W1ERK Liquid pipe ø12 7mm Gas pipe ø19 05mm 1UH250W1ERK Liquid pipe ø12 7mm Gas pipe ø22 2mm 7 5 3 Limitations for one way piping length and vertical height difference for single split Model 1UH071N1ERG 1UH090N1ERG 1UH105N1ERG 1UH125P1ERG 1UH125P1ERK 1UH140P1ERG 1UH140P1ERK 1UH160P1ERG 1UH200W1ERK 1UH250W1ERK One way piping length less than 50 m less than 75 m less than 75 m Ver...

Страница 142: ... four directions A B C D E A Forward B Backward C Sideways D Downward E Power supply cable outdoor and indoor connection cable Cutting out the two slits makes it possible to install as shown in the figure Field pipes in 4 directions Use a metal saw to cut out the slits To install the connecting pipe to the unit in a downward direction make a knock out hole by penetrating the centre area around the...

Страница 143: ...r unit is installed above the indoor unit the following can occur The condensed water on the stop valve can move to the indoor unit To avoid this please cover the stop valve with sealing material If the temperature is higher than 30 C and the humidity is higher than RH 80 then thickness of the sealing materials should be at least 20mm in order to avoid condensation on the surface of the sealing Be...

Страница 144: ...aragraph Vacuum drying or have leaks 2 Pressure leak test 2 1 Break the vacuum by pressurizing with nitrogen gas to a minimum gauge pressure of 0 2 MPa 2 bar Never set the gauge pressure higher than the maximum operation pressure of the unit i e 4 0MPa 40bar 2 2 Test for leaks by applying a bubble test solution to all piping connections Make sure to use a recommended bubble test solution from your...

Страница 145: ...es when charging refrigerant When the power is on please close the front panel when leaving the unit unattended Charging with an unsuitable substance may cause explosions and accidents so always ensur that the appropriate refrigerant R410A is charged This unit requires additional charging of refrigerant according to the length of refrigerant piping connected at the site Make sure to charge the ref...

Страница 146: ...service ports for vacuuming pressure relief or pressurizing the circuit In case it is required to perform brazing on the unit ensure that there is no pressure remaining inside the unit Internal pressures need to be released with ALL the service ports indicated on the figures below opened The location is depending on mode type 7 7 4 Total charging weight of the refrigerant after a leak etc The tota...

Страница 147: ...l devices all supply circuits must be interrupted Be sure to install an earth leakage circuit breaker in accordance with aplicable legislation Failure to do so may cause electrical shock Use only copper wires A main switch or other means for disconnection having a contact separation in all poles must be incorporatedin the fixed wiring in accordance with applicable legislation Do not turn on the ma...

Страница 148: ... 1UH200W1ERK 1UH250W1ERK Power supply cable For 1UH125 140P1ERK H05RN F 5G 2 5mm2 For1UH200 250W1ERK H05RN F 5G 4 0mm2 Indoor and outdoor connection cable H05RN F 4G 2 5mm2 Y Y For single phase power supply models 1UH071N1ERG 1UH090N1ERG 1UH105N1ERG Power supply cable H05RN F 3G 4 0mm2 1UH125P1ERG 1UH140P1ERG 1UH160P1ERG Power supply cable H05RN F 3G 6 0mm2 Indoor and outdoor connection cable H05R...

Страница 149: ...ctric wiring diagram for electrical wiring works Form the wires and fix the cover firmly so that the cover may be fit in properly Do not connect wires of different gauge to the same power supply terminal Looseness in the connection may cause overheating When you do not use a wire conduit be sure to protect the wires with vinyl tubes to prevent the edge of the knock out hole from cutting the wires ...

Страница 150: ...e extra refrigerant and the refrigerant piping length Be sure to perform a test run Be sure to fully open the liquid side and gas side stop valves If you operate the unit with stop valves closed the compressor will break down Be sure to execute the first test run of the installation in cooling mode operation Never leave the unit unattended with an open front panel during test run 7 10 2 Precaution...

Страница 151: ...ged plarform it may topple over causing injury When installing draining pipes follow the instructions in the manual and make sure that they properly drain water so as to avoid dew condensation If not installed properly they may cause water leaks and damage the furnishings Properly dispose of the packing materials Things such as nails may be included in the package Dispose of them properly to preve...

Страница 152: ...eparate the DRED module to 7 parts as shown a Fix Pin 1 for contractor supplied line through nut 1 seal ring 2 tapered cup nut 3 insert to stud 4 b Repeat step 1 for fixed DRM line c Tighten the screw position on both sides a Tighten the DRED module to right side plate b Tighten the screw Insert the DRED terminal into the 5 core ports CN18 in PCB check the picture c Refit the trim cover 3 4 ...

Страница 153: ...ouch bush 2 For power supply cable and connection cable installation 3 Free insulation protection strip 1 For protecting the Connecting pipe 4 Drain connections 4 For Connecting the drain pipe 5 Instructions 1 Air conditioner operation 6 Damping rubber pad 4 Used to reduce vibration of the unit 7 Cable tie 2 For fixing the power cable and connecting cable No Name Quantity Descriptions Shape 1 Free...

Страница 154: ...and Toublleshooting 1 Indoor Unit 153 2 Indoor Unit Dip Switch Setting 159 3 Outdoor Unit PCB Photo 165 4 Failure Code 172 5 Instructions of Parameters Error Code Checking 195 6 Function 204 7 Controller 216 Appendix Sensor Characteristic 232 ...

Страница 155: ...153 Smart Power 1 Indoor Unit 1 1 ABH071K1ERG ABH090K1ERG ABH105K1ERG ABH125K1ERG ABH140K1ERG PCB CODE 0151800208 ADH071M3ERG PCB CODE 0151800267 1 2 ADH071M1ERG ADH090M1ERG PCB CODE 0151800175B ...

Страница 156: ...154 Smart Power 1 3 ADH105M1ERG AD125M1ERG AD140M1ERG PCB CODE 0151800106E 1 4 ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG PCB CODE 0151800227B PCB CODE 0151800311 ...

Страница 157: ...155 Smart Power ADH200H1ERG ADH250H1ERG ...

Страница 158: ...two group of DC 12V into CN3 CN4 WIFI WIFI MODULE Wifi module power supply and wifi module communication CN5 TRANS1 Transformer primary side Transformer primary side connector Transformer primary side input CN6 DC FAN COMM Fan motor driver board s CN1 Communication port for indoor main control PCB and fan motor driver board 5V DATA GND corresponding to 5V DATA GND in sequence CN7 AIR LINK E A O Re...

Страница 159: ...affle swing Function reserved only valid in future CN15 Up down swing motor Step motor for Up down swing Up down baffle swing CN18 Float Float switch with pump model or short circuit connector without pump model Input port for Float switch status open or close Dry contact input CN19 Remote Remote control detector YCJ A002 Communication port for remote control detector YCJ A002 for remote control I...

Страница 160: ...th power at least one of them flash or lit without power none of them flash or lit 2 Error indicate only LED3 flashes indoor error LED4 flash M times then LED3 flash N times outdoor error 3 Indoor outdoor communication indicate LED4 and LED3 keep flashing alternately LED4 LED4 Power indicate or error indicate or indoor outdoor communication indicate SW1 SW1 Model and function selection Details ref...

Страница 161: ...s when out of factory ABH071K1ERG ABH090K1ERG ABH105K1ERG ABH125K1ERG ABH140K1ERG PCB code 0151800208 BM3 5 BM3 6 BM3 7 BM3 8 Indoor unit Address Indoor unit address for one wired controller control more than one unit OFF OFF OFF OFF 0 master OFF OFF OFF ON 1 slave OFF OFF ON OFF 2 slave OFF OFF ON ON 3 slave OFF ON OFF OFF 4 slave OFF ON OFF ON 5 slave OFF ON ON OFF 6 slave OFF ON ON ON 7 slave O...

Страница 162: ...DUCT ADH071M1ERG ADH090M1ERG PCB code 0151800175B SW2 1 SW2 2 SW2 3 SW2 4 Indoor unit Address Indoor unit address for one wired controller control more than one unit OFF OFF OFF OFF 0 master OFF OFF OFF ON 1 slave OFF OFF ON OFF 2 slave OFF OFF ON ON 3 slave OFF ON OFF OFF 4 slave OFF ON OFF ON 5 slave OFF ON ON OFF 6 slave OFF ON ON ON 7 slave ON OFF OFF OFF 8 slave ON OFF OFF ON 9 slave ON OFF O...

Страница 163: ...ss Zone address 0 0 0 0 0 master default 0 0 0 1 1 slave 0 0 1 0 2 slave 0 0 1 1 3 slave 1 1 1 1 15 slave BM1 1 ON 0 OFF Capacity SW1 1 SW1 3 Room card SW1 4 Running mode Unit Type Area Description SW1 1 SW1 2 SW1 3 SW1 5 SW1 6 SW1 7 SW1 8 1 1 0 ADH071M3ERG 0 Room card invalid default 1 Room card valid 0 Heat pump default 1 Cooling only 0 Fresh air default 1 Error alarm 0 Filter alarm invalid defa...

Страница 164: ...G ADH125M1ERG ADH140M1ERG PCB code 0151800106E SW3 1 SW3 2 SW3 3 SW3 4 Indoor unit Address Indoor unit address for one wired controller control more than one unit OFF OFF OFF OFF 0 master OFF OFF OFF ON 1 slave OFF OFF ON OFF 2 slave OFF OFF ON ON 3 slave OFF ON OFF OFF 4 slave OFF ON OFF ON 5 slave OFF ON ON OFF 6 slave OFF ON ON ON 7 slave ON OFF OFF OFF 8 slave ON OFF OFF ON 9 slave ON OFF ON O...

Страница 165: ...With filter reminding OFF Reseved ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG PCB code 0151800227B SW3 5 SW3 6 SW3 7 SW3 8 Indoor unit Address Indoor unit address for one wired controller control more than one unit 0 0 0 0 0 master 0 0 0 1 1 slave 0 0 1 0 2 slave 0 0 1 1 3 slave 0 1 0 0 4 slave 0 1 0 1 5 slave 0 1 1 0 6 slave 0 1 1 1 7 slave 1 0 0 0 8 slave 1 0 0 1 9 slave 1 0 1 0 10 slave 1 0...

Страница 166: ...T Wired controller communication address SW2 1 SW2 2 SW2 3 SW2 4 Indoor unit Address Indoor unit address for one wired controller control more than one unit OFF OFF OFF OFF 0 master OFF OFF OFF ON 1 slave OFF OFF ON OFF 2 slave OFF OFF ON ON 3 slave OFF ON OFF OFF 4 slave OFF ON OFF ON 5 slave OFF ON ON OFF 6 slave OFF ON ON ON 7 slave ON OFF OFF OFF 8 slave ON OFF OFF ON 9 slave ON OFF ON OFF 10 ...

Страница 167: ...00054B 0150401824 1UH090N1ERG 0151800054B 0150401824 1UH105N1ERG 0151800054B 0150401824 1UH125P1ERG 0151800054B 0150401824 1UH125P1ERK 0151800054B 0150401826 1UH140P1ERK 0151800054B 0150401826 1UH160P1ERG 0151800054H 0150402356 1UH200W1ERK 015180054E 0151800185AE 1UH250W1ERK 015180054E 0151800185AE ...

Страница 168: ...166 Smart Power PCB 0151800054H ...

Страница 169: ...167 Smart Power Power module 0150401826 ...

Страница 170: ...168 Smart Power Power module 0150402356 Power module 0150401824 ...

Страница 171: ...0 1 1 3 0 0 0 0 0 1 0 0 4 0 0 0 0 0 1 0 1 5 0 0 0 0 0 1 1 0 6 0 0 0 0 0 1 1 1 7 1 1 1 1 1 1 1 1 256 SW8 Defination 0 1UH071N1ERG 1 1UH090N1ERG 2 1UH105N1ERG 4 1UH125P1ERG 5 1UH140P1ERG 8 1UH125P1ERK 9 1UH140P1ERK Note 1 If the outdoor unit connects with centralized controller the unit no displayed on controller Unit address 1 2 The centralized controller includes YCZ G001 YCZ A003 YCZ A004 the max...

Страница 172: ...0 0 0 0 1 0 2 0 0 0 0 0 0 1 1 3 0 0 0 0 0 1 0 0 4 0 0 0 0 0 1 0 1 5 0 0 0 0 0 1 1 0 6 0 0 0 0 0 1 1 1 7 1 1 1 1 1 1 1 1 256 SW7 1 ON 0 OFF Defination SW7 1 SW7 2 0 0 DERD test selection 0 0 1 DERD test selection 1 1 0 DERD test selection 2 1 1 DERD non test selection SW8 Defination 7 1UH160P1ERK Note 1 If the outdoor unit connects with centralized controller the unit no displayed on controller Uni...

Страница 173: ... in System Settings must be Single Outdoor unit dip switch setting 0151800054E Dip switch setting Model 1UH200W1ERK 1UH250W1ERK SW1 1 SW1 2 SW1 3 SW1 4 SW1 5 SW1 6 SW1 7 SW1 8 Description OFF Manually forced operation invalid default ON Manually forced operation valid OFF Manually forced heating default ON Manually forced cooling OFF Normal standby cost default ON Low stand by power cost OFF Water...

Страница 174: ...ion between wired controller or I R RECE IVER and indoor unit Wrong connection or wired controller broken or PCB faulty 0 12 0C Malfunction of drain system Pump motor disconnected or at wrong position or the float switch disconnected or at wrong position or the short circuit bridge disconne ted 0 13 0D Zero cross sigal wrong Zero cross sigal detected wrong 0 14 0E Indoor unit DC fan motor abnormal...

Страница 175: ...1 outdoor main control PCB EEPROM malfunction Malfunction of outdoor unit Refer to outdoor unit trouble shooting list to get more details 16 2 PIM power intelligent module hardware overcurrent 17 3 Compressor over current during deceleration 18 4 Communication abnormal between control board and compressor driver module 19 5 Compressor overcurrent detected by control board 1A 6 DC voltage or AC vol...

Страница 176: ...it fault 30 28 No wiring of the compressor 39 37 Compressor overcurrent detected by compressor driver module 3A 38 Drive module s ambient temp sensor abnormal 3B 39 Mid condenser temp sensor TC abnormal 3E 42 High pressure switch abnormal open circuit 3F 43 Low pressure switch abnormal open circuit 40 44 Outdoor condenser temperatureTC too high protection 41 45 System low pressure protection Note ...

Страница 177: ...ction 0 12 0C Malfunction of drain system Pump motor disconnected or at wrong position or the float switch disconnected or at wrong position or the short circuit bridge disconne ted 0 13 0D Zero cross sigal wrong Zero cross sigal detected wrong 0 14 0E Abnormal communication between main control PCB fan motor drive Communication wire disconected or wrong conected or PCB hardware malfunction 0 15 0...

Страница 178: ...t Wrong connection or wired controller broken or PCB hardware malfunction 0 12 0C Malfunction of drain system Pump motor disconnected or at wrong position or the float switch disconnected or at wrong position or the short circuit bridge disconne ted 0 13 0D Zero cross sigal wrong Zero cross sigal detected wrong 0 14 0E Indoor unit DC fan motor abnormal DC Fan motor disconnected or DC Fan broken or...

Страница 179: ...munication between wired controller and indoor unit Wrong connection or wired controller broken or PCB faulty 0 12 0C Malfunction of drain system Pump motor disconnected or at wrong position or the float switch disconnected or at wrong position or the short circuit bridge disconneted 0 13 0D Zero cross sigal wrong Zero cross sigal detected wrong 0 14 0E Indoor unit DC fan motor abnormal DC Fan mot...

Страница 180: ...cted or related circuit broken Error status confirm and lock if occurs 3 times within 30 minutes Non resumable 10 Outdoor defrosting temp sensor Te abnormal Sensor temperature been detected below 55 C or higher than 90 C or been detected as short circuit or open circuit Resumable 11 Suction temp sensor Ts abnormal 12 Outdoor ambient temp sensor Ta abnormal Sensor temperature been detected below 40...

Страница 181: ...essor No wiring between compressor and it s driver module Non resumable 37 Compressor overcurrent detected by compressor driver module Compressor phase U or V or W current over 27A single phase model or 19 1A single phase model occured during non rated period Resumable 38 Drive module s ambient temp sensor abnormal The temperature detected is not within the range of 25 C to 150 C Resumable 39 Mid ...

Страница 182: ... or related circuit broken Error status confirm and lock if occurs 3 times within 30 minutes Non resumable 10 Outdoor defrosting temp sensor Te abnormal Sensor temperature been detected below 55 C or higher than 90 C or been detected as short circuit or open circuit Resumable 11 Suction temp sensor Ts abnormal 12 Outdoor ambient temp sensor Ta abnormal Sensor temperature been detected below 40 C o...

Страница 183: ...e 37 Compressor overcurrent detected by compressor driver module Compressor phase U or V or W over current detected by compressor driver module details refer to service manual Non resumable 38 Drive module s ambient temp sensor abnormal The temperature detected is not within the range of 25 C to 150 C Resumable 39 Mid condenser temp sensor TC abnormal The temperature detected is not within the ran...

Страница 184: ...rdware software protection Error detail Protection Level Error symbol 1 Software PIM module overheat 105 C and continued 5s 01H 2 Software PIM temperature sampling failure 18H 3 Software Overcurrent protection when limit frequency 02H 4 Hardware Hardware protection PIM_INT PIM_INT 04H 6 Software DC under voltage 180V 05H 7 Software DC high voltage 390V 06H 8 Software Communication error 07H 9 Soft...

Страница 185: ...ection current RMS compressor phase current compressor phase current protection recovery current RMS forbid increase the compressor frequency Forbid increase the compressor frequency Protection recovery Compressor phase current Compressor phase current protection recovery current RMS cancel the compressor limit frequency protection and normally operation Drive input current protection Error protec...

Страница 186: ...l range or the 30s not receive correct communication data that the communication failure execute communications shutdown protection while communication returns the corresponding error code After the communication failure if the receiver again to correct data and models within the model code range then cancel the error Note For debug mode when the model code is not within the range of models senten...

Страница 187: ...urrent RMS 8A 18 PFC open switch voltage 360V 19 PFC off switch current RMS 5A Compressor type TNB306FFEMC No Error description Device protection value 1 Compressor phase current Limit frequency protection shutdown current value RMS 23A 2 Compressor phase current Limit frequency protection decrease frequency current value RMS 18A 3 Compressor phase current Limit frequency protection recovery curre...

Страница 188: ...ion Level Error symbol 1 Software PIM module overheat 105 C and continued 5s 01H 2 Software PIM temperature sampling failure 18H 3 Software Overcurrent protection when limit frequency 02H 4 Hardware Hardware protection PIM_INT PIM_INT 04H 6 Software DC under voltage 180V 05H 7 Software DC high voltage 390V 06H 8 Software Communication error 07H 9 Software Output lack of Phase 16H 10 Software Reser...

Страница 189: ...ion current RMS compressor phase current compressor phase current protection recovery current RMS forbid increase the compressor frequency Forbid increase the compressor frequency Protection recovery Compressor phase current Compressor phase current protection recovery current RMS cancel the compressor limit frequency protection and normally operation Input current protection of driver Error prote...

Страница 190: ...ompressor stop then drive into the input overvoltage protection Input voltage overvoltage recovery value cancel input overvoltage protection Communication error Drive priority detect the model code after power on the 30s after power on is the time for the model code setting And need to complete the model code setting within this 30s if setting completely are not allowed to change Compressor type M...

Страница 191: ...tion error code Error code Hardware software protection Error detail Protection Level Error symbol 1 Software PIM module overheat 105 C and continued 5s 01H 2 Software PIM temperature sampling failure 18H 3 Software Overcurrent protection when limit frequency 02H 4 Hardware Hardware protection PIM_INT PIM_INT 04H 6 Software DC under voltage 300V 05H 7 Software DC high voltage 700V 06H 8 Software C...

Страница 192: ...e the compressor frequency Protection recovery Compressor phase current Compressor phase current protection recovery current RMS cancel the compressor limit frequency protection and normally operation DC bus over under voltage protection Bus voltage overvoltage shutdown value the compressor stop then drive into the bus overvoltage protection Bus voltage overvoltage recovery value cancel the bus ov...

Страница 193: ...it frequency protection decrease frequency current value RMS 18 4A 3 Compressor phase current Limit frequency protection recovery current value RMS 17 7A 4 PIM temperature shutdown protection 105 C 5 DC bus overvoltage shutdown value 700V 6 DC bus overvoltage recovery value 650V 7 DC bus under voltage shutdown value 370V 8 DC bus under voltage recovery value 430V 9 Communication shutdown protectio...

Страница 194: ...ion 2 5min then ERROR Recovery 3 Protection error lists Error code Hardware software protection Error detail Protection Level Error symbol 1 Hardware Inverter side hareware momentary over current 04H 2 Software Inverter side momentary over current detection 45A 08H 3 Software Heat sink temperature abnormal 95 C protection 90 C recovery 0CH 4 Software Over load 10H 5 Software Under voltage detectio...

Страница 195: ...ency protection current RMS compressor phase current compressor phase current protection recovery current RMS forbid increase the compressor frequency Forbid increase the compressor frequency Protection recovery Compressor phase current Compressor phase current protection recovery current RMS cancel the compressor limit frequency protection and normally operation Input current protection of driver...

Страница 196: ...n Input voltage voltage recovery value cancel the under voltage protection Drive come with AC voltage detection avoid the input voltage is too high damage the device Input voltage overvoltage shutdown value the compressor stop then drive into the input overvoltage protection Input voltage overvoltage recovery value cancel input overvoltage protection Communication error If model code is our of mod...

Страница 197: ...s of Parameters Error Code Checking 5 1 From where to do the parameters checking work 5 2 Where are the digital LED display and the button switches One digital LED display and 4 button switches which on the outdoor main control PCB ...

Страница 198: ...48 2 1UH140P1ERG 60 2 1UH125P1ERK 48 4 1UH140P1ERK 60 4 1UH160P1ERG 72 2 b Then after step a if the communication between indoor outdoor unit established correct the LED digital display will show the quantity of indoor units For single splits system it will show 1UN For MAXI split system it will show 2UN or 3UN or 4UN c Then after step b and if has reached the outdoor unit s start time the LED dig...

Страница 199: ...ater if no start again signal received by the indoor unit the LED digital display will extinguished Step1 Press and hold the MODE button for 5 seconds then release then the LED digital display will show the current mode and will keep flashing Step2 Press and hold the SET button for 3 seconds then release LED digital display will keep the mode lit without flashing Step3 Press and hold the SET butto...

Страница 200: ...198 Smart Power Fig 4 1 ...

Страница 201: ...199 Smart Power Fig 4 2 ...

Страница 202: ... A 12 Co b Cool mode of SEER test condition B 13 Co C Cool mode of SEER test condition C 14 Co d Cool mode of SEER test condition D 15 Co E Cool mode of SEER test condition E 16 Co F Cool mode of SEER test condition F 17 Co H Cool mode of SEER test condition F 18 CO I Cool mode of SEER test condition I 19 CO J Cool mode of SEER test condition J 20 Ht N Heat mode of EER test condition 21 Ht A Heat ...

Страница 203: ...unit fan speed level 31 tAo Temperature of outdoor ambient 32 tc Temperature of outdoor condenser 33 td Temperature of outdoor discharge 34 tE Temperature of outdoor defrost 35 tS Temperature of outdoor suction 36 tdr Temperature of compressor driver module 37 Idr Current of the compressor 38 tH Temperature of heat water reserved 39 tAI Temperature of indoor ambient 40 TCI Temperature of indoor co...

Страница 204: ...old the MODE button for 5 seconds then release then the LED digital display will show the current mode and will keep flashing Step2 Scroll pages to view the other modes by UP or DOWN button Step3 Continue with step 2 find mode dig press and hold the SET button for 3 seconds then release Step3 Continue with step 3 press and hold the SET button for another 3 seconds then release the LED digital disp...

Страница 205: ...W4 SW2 MODE DOWN SET DOWN SET DOWN SET DOWN UP MODE UP MODE UP SW5 SW3 SW5 SW3 SW4 SW2 MODE UP SW5 SW3 SET DOWN SW4 SW2 MODE UP SW5 SW3 SW5 SW3 Mode is cool Coo will flashing diA flashing Scroll pages to view the other modes by UP or DOWN button Press and hold for 3 seconds then release diA lit without flashing Scroll pages to view the other last N times N 10 error code by UP or DOWN button number...

Страница 206: ...r off 15 minutes Or it will still stay on cooling mode and will stop after reaching the setting temperature 3 Auto heating mode is same to heating mode The unit will enter auto cooling mode if Tai Tset 1 corrected Tdif after temperature sensor off 15 minutes Or it will still stay on heating mode 4 This mode has sleep function In cooling mode it will enter cooling sleep the same to heating Once set...

Страница 207: ...y the conditions what has been line out in above table cold wind prevention priority The longest running time is 50 seconds 4 Cold wind prevention control in defrost mode After receive the defrost signal indoor unit will blow after heat for 20 seconds in low speed and then stop Or it will stop if indoor coil temperature is less than the temperature of cold wind prevention After defrost indoor unit...

Страница 208: ...e emergent switch when starting up the unit the indoor unit will shut down then it come to the normal control 2 Test run When in shut down state keep pressing the emergent button you will hear two buzzers after 5 seconds and then release the button to remember the last shutdown mode if it s cooling mode last time it s cooling high speed wind and setting 16 C now if it s heating mode it s heating h...

Страница 209: ...ernalstatic pressure setting A by Infrared remote controller B by wired controller MOEDL Static pressure level N Externalstatic pressure Select by Infrared remote controller Select by wired controller ADH105M1ERG ADH125M1ERG ADH140M1ERG 1 30Pa YR HBS01 RE 02 FAN mode fan speed high press HEALTH button 4 N times 1 N 10 integer within 12 seconds Select static pressure Level N by the display interfac...

Страница 210: ... press Fan Set keys for 5s to enter static pressure grade adjustment Press together and hold for 5 seconds 2 2 State with static pressure icon flashing and current static pressure grade statically displaying 2 3 Press key to change static pressure grade N 1 N 10 integer then press Set key to confirm Use these buttons to adjust static pressure level numbers press Set key to confirm ...

Страница 211: ...HZ S Fast frequency reduction 1HZ 10S Keep frequency Slow frequency up 1HZ 10S Common control 6 2 2 Condenser overheat protection When cooling compare TC with TE Choose the bigger one TC TC MAX TC TE You can control the high pressure through controlling TC Slow frequency up 1HZ 10S Common control 65 C TC _cooling 64 C 61 C 59 C 55 C If it lasts 5 seconds the unit will stop and alarm After standing...

Страница 212: ...will stop and alarm for ever It will disappear if unit back to power The lowest running frequency 20HZ The lowest running frequency 20HZ The lowest running frequency 20HZ Normal running When heating you can judge through comparing defrost temp Te with environment temp Tc and choose the lower one Teva h Teva_h 30 C 35 C 40 C 45 C 50 C If it lasts 5 seconds unit will stop and Alarm After standing by...

Страница 213: ...r working frequency is higher than B HZ E and lasts more than 10 minutes the time reset When heating the time will reset if the defrost mode work After oil return oil return timer reset After oil return the condition of end of refrigerant ruled running OR OR Oil return after 1 minutes The longest 3 minutes Td TC 30 C Ts TM 30 C TM 35 C Process control chart of oil return Send oil return signal Sta...

Страница 214: ...lization action of the EEV Driving speed of the EEV Open way 31 25 PPS 32MS Closed way 31 25 PPS 32MS full open action and full closed action of EEV full open action open as 470 pulse E full closed action after closing 540 pulse repeat three times close as 60 pulse and open as 5 pulse it means stop at opening of 5 Process control chart of oil return Send oil return signal Start End Inverter comp I...

Страница 215: ...e 2 Passive shut down mode Error protection shut down When the system come to the pressure protection over current protection high module temperature protection high condensation temperature protection and the unit shut down no matter the frequency of the compressor come to 55HZ the unit will shut down directly 6 2 7 Defrosting control in heating mode In heating mode condenser heat exchanger defro...

Страница 216: ...owing conditions four way valve should be OFF 1 in heating mode in initial starting time of compressor to ensure the pressure difference 1 in defrosting operation a if there is no compressor stopping power four way valve off 2 Defrosting end contition After defrosting condition starts it will last no more than 10 minutes E Using Te to test outdoor heat exchanger frosting condition if it lasts over...

Страница 217: ...inning END 60S 60S 30S 30S Inverter compressor Defrosting FQYH Soft startup 10s Outdoor fan motor ON Send signal to indoor uni ON OFF 4 way valve ON ON OFF ON Unload valve SV1 Auto Open angle E PMV Auto open angel Anti cold air function Indoor fan motor ON OFF ...

Страница 218: ...216 Smart Power 7 Controller External View of Remote Controller 7 1 Remote Controller YR HBS01 ...

Страница 219: ...h mode otherwise parameters set last time will be showed Mode SMART HEAT COOL DRY FAN Initial TEMP 24 C 24 C 24 C 24 C Setting temperature is not showed Mode SMART HEAT COOL DRY FAN Initial Fan Speed AUTO LOW HI AUTO LOW 5 FAN Mode 1 During power OFF press HEALTH button or FRESH button to enter FAN mode with low fan speed Meanwhile the HEALTH or FRESH icon will be showed on the screen 2 Temperatur...

Страница 220: ...r side simultaneous control of Four side Embedment Four side Embedment 1 Four side Embedment 2 Four side Embedment 3 Four side Embedment 4 Four side simultaneous control of Four side Embedment 3 When pressing Four side Embedment button to select air deflector the selected air deflector flashes Press Up and down Angle button to adjust angle of air deflector at the moment 9 Up and down SWING Angle 1...

Страница 221: ...n At the same time the icon disappears and icon is shown if QUIET function is set at present press button SLEEP while QUIET function is still kept 4 This function is valid under the mode of COOL or HEAT 5 Turbo QUIET functions are not memorized among switch of all modes the state of on or OFF 16 IFP 1 Press IFP button display IFP function is set and press IFP button again to cancel 2 Press Follow ...

Страница 222: ... one performed second After the time of clock performed first is end corresponding characters of timer ON OFF disappear If time of TIMER ON is the same as that of TIMER OFF and can not be verified corresponding character of the latter of setting time is always flashing it is necessary to readjust time and confirm again If time of TIMER ON OFF is the same as that of clock at present and can not be ...

Страница 223: ...M icon after 3 seconds In energy saving mode and temp compensation mode the adjusting step is 1 C a time If using Fresh Air unit set temp cannot be adjusted If there is no Central Lock set the temp will be fixed at 18 C in cooling and 22 C in heating The Up Down key will not display in normal state but will display and valid in timer setting function selection unit shift in malfunction inquiry par...

Страница 224: ...ess this key to enter function circulation 1 Press to select the functions in sequence as follows 2 Press to select the functions in sequence as follows 3 Press to confirm function selected If there is function selected press can cancel this function Note The Left Right swing is valid only after the dip switch is set the filter icon is shown only after the filter requires cleaning Icon Clock Param...

Страница 225: ...n the following sequence Low Medium High Low AUTO icon will display simultaneously 7 1 Operation Dip Switch Interpretation for AC DIP switch On Off station Function Default setting Sw1 On Slave wired controller Off Off Master wired controller Sw2 On Ambient temp display on Off Off Ambient temp display off Sw3 On Collect ambient temp from PCB of indoor Off Off Collect ambient Temp from wired contro...

Страница 226: ... Up Down key at the main interface and then press together Time and Down key to enter screen saving time setting Clock Function 1 24 hour system is used and at first time of powering on it will display default 12 00 2 When first powering on wired controller will be displayed on the wired controller interface clock time can be adjusted within 10s At the same time clock icon and minute place of time...

Страница 227: ...ess to confirm the setting the setting time is displayed and OFF will not flash If there is no input for 10s this setting will be cancelled and the timer will come back to the previous state Timer ON OFF Press key it displays default for the first time previous setting will be displayed if there is setting before Then hour position and ON are flashing Press key again the minute position and ON are...

Страница 228: ...ler unit Sleeping 1 Press key to enter function setting press to the sleeping icon and it will flash the sleeping time will display by the which is on the top right corner Press Time key to enter sleeping time setting OFF and sleeping icon are flashing Press to adjust the sleeping time by 0 5h once the range of sleeping time is from 0 5h to 72h After the adjustment press key again to confirm the o...

Страница 229: ... controller and indoor unit is valid 4 Fresh Air unit can execute mode setting it will execute the intersection with three modes of Fresh Air unit cooling heating fan mode 5 This setting is ground floor setting and will be memorized whether non volatile memory invalid or valid Malfunction Display 1 The main interface does not display malfunction 2 Under no screen saving state press key for 10 seco...

Страница 230: ...munication address between indoor and outdoor unit is static which can only be inquired 3 Wired controller s address is displayed before the colon of clock on the top left corner ranging from 0 to 15 and displayed in decimal system 4 The communication address between indoor and outdoor unit is displayed on the top left corner The default value is the current unit s address selecting other indoor u...

Страница 231: ...splay error code 07 when checking malfunction Sensor Malfunction If the dip switch is set to collect ambient Temp from wired controller and the sensor can t work normally it will display error code 01 when checking malfunction Temp Compensation Setting 1 In OFF state keep pressing key for 5 seconds the current temp compensation value is displayed on the top right of the screen and flashes 00 is th...

Страница 232: ...roller directly the others connect with the master unit through 2 pieces of polar wire B One wire controller controls one indoor unit and the indoor unit connects with the wire controller through 3 pieces of polar wire C Two wired controllers control one indoor unit The wired controller connected with indoor unit is called master one the other is called slave one Master wired controller and indoor...

Страница 233: ...ON1 B 3 2 1 B red yellow white A 2 Fix back cover to the holder After that connect communication wire to CON1 port of wired controller Finally put the front cover of wired controller to back cover to complete the installation ...

Страница 234: ...K 3 1UH071N1ERG 1UH090N1ERG 1UH105N1ERG 1UH125P1ERG 1UH125P1ERK 1UH140P1ERK 1UH160P1ERG Defrosting temp sensor 0010450194 R25 10KΩ 3 B25 50 3700K 3 Ambient temp sensor 0010450192 R25 10KΩ 3 B25 50 3700K 3 Discharging temp sensor 0010451303 R80 50KΩ 3 B25 50 4450K 3 Outdoor coil temp sensor 0010451329 R25 10KΩ 3 B25 50 3700K 3 Sunction temp sensor 0010451307 R25 10KΩ 3 B25 50 3700K 3 1UH200W1ERK 1U...

Страница 235: ...4 66 70 41 11 24 78 2 76 115 0 88 5 63 18 42 10 78 79 2 66 116 0 86 6 59 86 43 10 33 80 2 58 117 0 84 7 56 74 44 9 91 81 2 49 118 0 81 8 53 80 45 9 51 82 2 41 119 0 79 9 51 03 46 9 12 83 2 33 120 0 77 10 48 42 47 8 76 84 2 26 121 0 75 11 45 97 48 8 41 85 2 18 122 0 73 12 43 65 49 8 07 86 2 11 123 0 71 13 41 46 50 7 75 87 2 05 124 0 69 14 39 40 51 7 45 88 1 98 125 0 67 15 37 46 52 7 16 89 1 92 126 ...

Страница 236: ... 9 49 4 25 10 59 2 81 8 46 86 26 9 59 60 2 72 7 44 46 27 9 21 61 2 63 6 42 21 28 8 84 62 2 54 5 40 08 29 8 48 63 2 49 4 38 08 30 8 15 64 2 38 3 36 19 31 7 83 65 2 3 2 34 41 32 7 52 66 2 23 1 32 73 33 7 23 67 2 16 0 31 14 34 6 95 68 2 09 1 29 64 35 6 68 69 2 03 2 28 22 36 5 43 70 1 96 3 26 4 37 5 6 71 1 9 4 25 61 38 5 59 72 1 85 5 24 41 39 5 73 73 1 79 6 23 27 40 5 52 74 1 73 7 22 2 41 5 32 75 1 68...

Страница 237: ...1036 42 232 19 5736 12 983 2 43 221 9 18 5392 13 933 4 44 212 3 17 5071 14 886 4 45 203 2 16 4770 15 841 9 46 194 5 15 4488 16 800 47 186 3 14 4225 17 760 8 48 178 4 13 3978 18 722 8 49 170 9 12 3747 19 687 3 50 163 7 11 3531 20 653 8 51 155 9 10 3328 21 622 52 150 4 9 3138 22 592 53 144 2 8 2960 23 553 6 54 138 3 7 2793 24 536 6 55 132 7 6 2636 25 511 1 56 127 3 5 2489 26 486 9 57 122 1 4 2351 27...

Страница 238: ...Haier Commercial Air Condition Web Http www haier com Haier reserves the right to make change without any notice ...