![Haier 1U48IN1EAB Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/haier/1u48in1eab/1u48in1eab_service-manual_134934041.webp)
Single Split
39
1
0
. Failure code
WCR : Failure code in pannel
CCR : Run lamp flash times
SN
WCR CCR
Failure description
1
E0
10
Float switch is disconnected 25min or longer.
2
E1
1
Indoor ambient s
ensor is open-circuit or short-circuit for
2min or longer.
3
E2
2
Indoor pipe sensor is open-circuit or short-circuit for 2min or
longer.
4
E3
3
Outdoor ambient sensor is open -circuit or short-circuit for
2min or longer.
5
E4
4
Outdoor discharge/pipe temp. s
ensor is open-circuit or short
-
circuit for 2min or longer.
6
E5
5
Current is too high or the turn of 3 phase is wrong.
7
E6
6
High or low pressure switch is open circle for 2 minutes.
8
E8
8
Communication problem between indoor and controller.
9
E9
9
Communication problem between indoor and outdoor unit.
0150514714
controller
Содержание 1U48IN1EAB
Страница 8: ...Single Split 6 5 Installation 1 2 1 2 3 4 1 2 1 2 3 4 2 ...
Страница 9: ...Single Split 7 ...
Страница 10: ...Single Split 8 ...
Страница 11: ...Single Split 9 ...
Страница 12: ...Single Split 10 ...
Страница 13: ...Single Split 11 ...
Страница 14: ...Single Split 12 ...
Страница 15: ...Single Split 13 ...
Страница 16: ...Single Split 14 pipe direction Right Left Rear Bottom Indoor outdoor unit connection ...
Страница 27: ...Single Split 25 8 PCB photo Indoor PCB 0010451850 ...
Страница 28: ...Single Split 26 Outdoor PCB 0010452441 ...