Service diagnosis
32
Domestic air conditioner
10.3 Error Codes and Description indoor display
Only For 498 and
498A display
(Red/Green Time Run
□
On
★
Flash
■
Off)
Indoor
and
Outdoo
r
E7 Directly display
■
■
★
15
Communication fault between
indoor and outdoor units
Page.42
E1 Directly display
★
■
■
/
Indoor temperature sensor failure Page.32
E2 Directly display
★
□
□
/
Indoor coil sensor failure
Page.32
E4 Directly display
★
□
★
/
Indoor eeprom failure
Page.33
E14 Directly display
■
□
★
/
Indoor fan failure
Page.34
E5 Trouble record
□
■
★
22
Internal unit antifreeze protection
Page.
E9 Trouble record
□
■
★
21
Internal unit overload
Page.45
F12 Directly display
■
★
■
1
Eeprom failure
Page.33
F1 Directly display
□
●
★
★
2
IPM failure
Page.37
F22 Directly display
★
●
★
■
3
AC current overcurrent protection Page.38
F3 Directly display
■
★
■
4
Communication error between
module board and main PCB
board.
Page.39
F20 Trouble record
■
●
★
□
5
High pressure protection
Page.45
F19 Trouble record
■
★
□
6
Power over/under voltage
protection
Page.40
F27 Directly display
■
★
■
7
Compressor stall / press
instantaneous stop
Page.40
F4 Directly display
■
★
■
8
Compressor discarging
temperature protection
Page.41
F8 Trouble record
■
★
□
9
Abnormal of DC motor
Page.36
F21 Directly display
□
□
★
10
Abnormal of piping sensor
Page.32
F6 Directly display
□
★
■
12
Abnormal of outdoor ambient
sensor
Page.32
F25 Directly display
★
□
■
13
Abnormal of compressor
discharge sensor
Page.32
F13 Trouble record
■
★
□
16
Lack of refrigerant
Page.
F14 Trouble record
■
★
□
17
4-way valve reverse failure
Page.
F11 Directly display
■
●
★
■
18
Compressor jam (only for spdu)
Page.44
F28 Directly display
■
★
■
19
Module PWM select circuit error
Page.44
F2 Trouble record
■
●
★
□
24
Instantaneous over-current
protection of the compressor
Page.38
F23 Trouble record
■
★
□
25
Compressor U-phase overcurrent
Compressor V-phase overcurrent
Compressor W-phase overcurrent
Page.38
F24 Trouble record
★
■
★
27
CT disconnection
Page.
F34 Trouble record
/
37
Outdoor coil protection
Page.
F35 Trouble record
■
★
□
38
Compressor driver board failure
Page.
F43
/
■
★
■
46
Model matching abnormality
Page.
Indoor
Malfunc
tion
Outdoo
r
Malfunc
tion
fault description
Referenc
e Page
Other display
Indoor displaying panel code indication
Code indication
Outdoor
(LED1
flash
times)
Содержание 1U35YEFFRA-C
Страница 11: ...Pinping diagrams Domestic air conditioner 4ˊPiping diagrams 9 ...
Страница 12: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40 ...
Страница 14: ...Functions and control 13 Domestic air conditioner Wiring diagrams OUTDOOR UNIT ...
Страница 37: ...Service diagnosis 37 Domestic air conditioner ...
Страница 56: ...57 Do C omestic air ircuit Diagra conditioner ams r ...
Страница 59: ...Removal Procedure 1 Removal of Outdoor panel RPHVWLF LU RQGLWLR ...
Страница 60: ...Removal Procedure 2 Domestic Air Condition ...
Страница 61: ...4 Removal Procedure 3 Domestic Air Condition ...
Страница 62: ...Removal Procedure 2 Removal of Electrical Box RPHVWLF LU RQGLWLR ...
Страница 63: ...Removal Procedure 3 Removal of Fan and Fan Motor RPHVWLF LU RQGLWLR ...
Страница 64: ...Removal Procedure 4 Removal of fan motor brcked and partition RPHVWLF LU RQGLWLR ...
Страница 65: ...Removal Procedure 7 Domestic Air Condition ...
Страница 66: ...Removal Procedure 5 Removal of compressor and heat exchanger RPHVWLF LU RQGLWLR ...
Страница 67: ...Removal Procedure 9 Domestic Air Condition ...