Capacity
Domestic Air Conditioner
11.2 Power consumption temperature curves
indoor temp.
DB/WB
ˉ
15
ć
ˉ
10
ć
0
ć
10
ć
20
ć
25
ć
30
ć
35
ć
40
ć
46
ć
18/12
ć
628
636
630
621
286
406
517
640
717
764
21/15
ć
638
652
642
625
291
411
530
652
731
809
24/16
ć
684
704
688
672
317
460
578
690
815
889
27/19
ć
704
719
704
688
329
464
593
707
836
893
30/22
ć
716
737
725
700
353
488
620
764
890
962
32/23
ć
732
740
742
707
357
513
663
806
920
998
power consumption value-temp.table