Method

1.There

is

no

working

when power on

*Check host power wire,controller,connector
connection is normal or not.
*Check Fuse,battery,and voltage is right or
not .

2.Light control abnormal

*Check Light control wire

is loose or

connected wrong

3.Speaker no sound

*Check Speaker wire,controller,connector is
normal or not .
*Check Speaker is broken or not.

4.No Volume

*Adjust the volume control

Notice:

Notice:

Notice:

Notice:

1.Positive and negative power supply can not be reversed.
2.This siren operating voltage 12V.
3.Attention to moisture, water.
4.Put in well-ventilated environment away from heat sources.
5.No using other parts to fix the siren which not from the original factory.

Содержание HA998 Series

Страница 1: ...he installation instructions carefully first in order to properly use and maintain this product Main Main Main Main parameter parameter parameter parameter Working Voltage DC11 13 8V Operating Temperature 30 45 Current 12A One Way HA998 100W Power 100W 8A HA998 150W Power 150W 12A HA998 200W Power 200W 16A HA998 300W Power 300W 24A HA998 400W Power 400W 32A HA998 600W Power 600W 48A HA998 800W Pow...

Страница 2: ...IL 1 5 TOOL PRIORITY 6 HILO PRIORITY 7 HIGH SPEED PULSE WAIL 1 Extra tones Light siren High siren 8 Seconds Alarm COCO Installation Installation Installation Installation 1 Put in ventilation environment as much as possible 2 Confirm assembly screws are tightened 3 Check siren host and controller wire connection are tightened 4 Can start to use the siren after full connection accordance with the w...

Страница 3: ...akers installed away from heat sources and do not hinder the spread of local and solid sound environment and fixed siren controller Controller Controller Controller Controller surface surface surface surface ...

Страница 4: ...Controller Controller H H H Host ost ost ost wiring wiring wiring wiring connection connection connection connection diagram diagram diagram diagram for for for for 100W 150W 200W 100W 150W 200W 100W 150W 200W 100W 150W 200W ...

Страница 5: ...on diagram diagram diagram diagram for for for for 300W 400W 300W 400W 300W 400W 300W 400W Wiring Wiring Wiring Wiring explanation explanation explanation explanation 1 Positive Red wire 2 Negative Black wire 3 Speaker Green wire 4 Speaker Green wire 5 Light power Red wire 6 Light 1 Brown wire 7 Light 2 Yellow wire 8 Light 3 Orange wire ...

Страница 6: ...bnormal Check Light control wire is loose or connected wrong 3 Speaker no sound Check Speaker wire controller connector is normal or not Check Speaker is broken or not 4 No Volume Adjust the volume control Notice Notice Notice Notice 1 Positive and negative power supply can not be reversed 2 This siren operating voltage 12V 3 Attention to moisture water 4 Put in well ventilated environment away fr...

Отзывы: