INSTALLATION INSTRUCTIONS  

 
The HAI UPB™ Appliance Module is simply plugged into a standard wall outlet.   

 

Load Information

 

 
The total load of the UPB™ controlled outlet must not exceed 15 Amps or ½ Horsepower. 

 

 
Switch Trigger Operation 
 

The Appliance Module can be configured to sense the load’s local on/off switch (switch trigger) to turn the load on even after it was 
turned off via UPB™ control.  By default, the Appliance Module has the switch trigger operation disabled. 
 
Note: This feature may not work for all types of loads (e.g. fluorescent lighting loads). 
 

HAI APPLIANCE MODULE OPERATION 

 
The HAI Appliance Module has many configurable items that can be set using the UPB™ UPStart configuration software.  The 
following describes the operation of the HAI Appliance Module in its factory default configuration.  
 

LED Indicator 

 
The HAI UPB™ Appliance Module comes equipped with a multi-color LED indicator that is normally lit to blue when the load is off. 
The LED will turn off when the load is turned on. 

 
Test Mode 
 

The Appliance Module’s controlled outlet can be tested using the Test Mode.  The Appliance Module can be put into test mode by the 
following steps: 
 

Step Operation 

Press and hold the pushbutton for at least 3 seconds to enter Test Mode. 

The HAI UPB™ Appliance Module will continuously blink its LED magenta to indicate that it is in Test Mode.  Note: 
the appliance module will automatically exit Test mode after 5 minutes. 

Press the pushbutton 1 time to turn the UPB™ controlled outlet on and off. 

Press and hold the pushbutton for at least 3 seconds to exit Test Mode. 

 

Setup Mode 

 
To configure the HAI UPB™ Appliance Module using an HAI controller or a PC running the UPB™ UPStart configuration software, 
it must be put into Setup Mode as follows: 
 

Step Operation 

Press the pushbutton switch quickly 5 times. 

The HAI UPB™ Appliance Module will cycle the load one time and blink its LED blue to indicate that it is in Setup 
Mode.  Note: the appliance module will automatically exit Setup mode after 5 minutes. 

 

Reset to Factory Default Settings 

 
To reset the HAI UPB™ Appliance Module to factory default settings: 
 

Step Operation 

On the HAI UPB™ Appliance Module that you want to reset to factory defaults, press the pushbutton switch quickly 5 
times. 

The HAI UPB™ Appliance Module will cycle the load one time and blink its LED blue to indicate that it is ready to be 
set to factory defaults. 

Press the pushbutton switch quickly 10 times to reset to factory default setting. 

The HAI UPB™ Appliance Module will cycle the load one time and blink its LED red to indicate that it has been reset. 

Press the pushbutton switch once more to stop the LED from blinking. 

 