HAI RC-90 Скачать руководство пользователя страница 13

1

1

3

3

 

OWNER'S MANUAL 
 
Following Installer Setup, check the option boxes (

) in the Owner's Manual according to the configuration of 

the thermostat. 
 
QUICK-REFERENCE SETUP GUIDE 
 
This table displays each Installer Setup item with its default setting.  The column labeled "CURRENT" can be 
used to write down the current settings if any changes are made to the default settings. 
 

Item Number 

Description 

Default  

Current 

 00  

Address 

 

 01  

Communication mode 

 

 02  

System options 

 

 03  

Display options 

 

 04  

Calibration offset 

30 

 

 05  

Cool setpoint limit 

51 

 

 06  

Heat setpoint limit 

91 

 

 07  

Not used 

 

 08  

Not used 

 

 09  

Cooling anticipator 

 

 10  

Heating anticipator 

 

 11  

Cooling minimum on/off time 

 

 12  

Heating minimum on/off time 

 

 13  

Not used 

 

 14  

Clock adjust 

30 

 

 15  

Filter reminder 

10 

 

 16  

System runtime (This week) 

 

 17  

System runtime (Last week) 

 

 
 
REMOTE SYSTEM WIRING DIAGRAMS 
 
This thermostat has been preprogrammed with energy saving settings recommended under the EPA Energy Star 
program.  When used with remote systems, HAI recommends that the thermostat be configured as "non-
programmable" (See Setup Item 03 - "Display Options"). 

 

 
HAI AUTOMATION SYSTEMS
 
 
The thermostat can be connected to an HAI automation system.  The controller can send commands to the 
thermostat to change mode, cool setting, heat setting, status of fan and hold, and other items. 
 
Run a 3 (or 4) conductor wire from the HAI system to the thermostat location.  All thermostats on an Omni, 
Omni II, OmniPro, or OmniPro II controller are connected to Zone 16 and Output 8.   
 

Содержание RC-90

Страница 1: ...eptable in the country in which this equipment is to be installed INSTALLATION Before installing this thermostat 1 Read all of the installation instructions carefully Read the Owner s Manual carefully...

Страница 2: ...TING When mounting the RC 90 grasp the thermostat by the sides avoiding the keys and unsnap the base from the face Holding the base to the wall so that the word TOP is upright and facing you 1 Mark th...

Страница 3: ...ation See Figures 9 10 Insert the cable into the connector on the thermostat circuit board marked COMM Upon completion of wiring the thermostat push all excess wiring into the hole in the wall Plug th...

Страница 4: ...check wiring be sure that there are no stray wires or wire strands at the connections 2 It is not necessary to connect the remote system COMM cable at this time 3 Connect power to the control transfo...

Страница 5: ...5 5 Figure 5 Installation as a Master thermostat...

Страница 6: ...6 6 Figure 6 Installation as a Slave thermostat Figure 7 Installation as a Zone thermostat with separate transformer Required by some zone panels...

Страница 7: ...EAT COOL or OFF CONFIGURING THE BACKLIGHT ON THE RC 90B The backlight on the RC 90B can be configured to one of three different modes 1 on for 30 seconds when a key is pressed 2 always on or 3 always...

Страница 8: ...play are the item number 2 The large blinking digits in the center of the display are the value of the item number 3 Press the Prog key to advance to the next item 4 Press the Hold key to return to th...

Страница 9: ...ferent modes These modes are 0 300 baud RS 232 mode for use with personal computers 1 100 baud System mode OmniLT Omni Omni II OmniPro and OmniPro II systems 8 PESM mode use with Model 1503 automation...

Страница 10: ...minder displays add 16 to each value The default setting is 1 04 Calibration offset This item is used to raise or lower the current temperature reading by 1 degree Fahrenheit or 1 2 degree Celsius If...

Страница 11: ...d heat setting is reached This is done to avoid overheating the air while the walls and furniture catch up A setting of 0 will disable this feature 0 No anticipation 3 5 Normal anticipation 10 Maximum...

Страница 12: ...y 30 No change The default setting is 30 Note If an HAI automation system is being used the controller system time is sent to the thermostat every minute This adjustment will have no effect 15 Filter...

Страница 13: ...ing minimum on off time 8 12 Heating minimum on off time 8 13 Not used 14 Clock adjust 30 15 Filter reminder 10 16 System runtime This week 17 System runtime Last week REMOTE SYSTEM WIRING DIAGRAMS Th...

Страница 14: ...TAT Connect the red COMM cable wire with the black COMM cable wire Make the connections as shown in Figure 9 using the supplied wire splices Note Do not connect the red COMM cable wire to 12V Figure 9...

Страница 15: ...be set to 24 Run a two conductor wire from the remote system or remote switch to the thermostat location Make the connections using supplied wire splices See Figure 10 Red and yellow wires are not us...

Страница 16: ...at keys for test remove jumper SYMPTOM ACTION TO TAKE 1 Check COMM connector and wiring 2 Check thermostat address setting 3 Check communications mode setting Control By Remote System Not Working 4 Ch...

Отзывы: