The thermostat supports the following command classes: 
 

COMMAND_CLASS_THERMOSTAT_MODE 
COMMAND_CLASS_THERMOSTAT_SETPOINT 
COMMAND_CLASS_THERMOSTAT_FAN_MODE 
COMMAND_CLASS_THERMOSTAT_FAN_STATE 
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE 
COMMAND_CLASS_SENSOR_MULTILEVEL 
COMMAND_CLASS_ASSOCIATION 
COMMAND_CLASS_CONFIGURATION 
COMMAND_CLASS_VERSION 
COMMAND_CLASS_MANUFACTURER_SPECIFIC 
COMMAND_CLASS_SWITCH_BINARY 
COMMAND_CLASS_CLOCK 

 
COMMAND_CLASS_THERMOSTAT_MODE 

 
Upon power up, allow 10 seconds for the RC-100BZ thermostat to initialize.  After 10 seconds, a controller can 
set the mode, get the current mode, and get the modes supported by the thermostat. 

 
COMMAND_CLASS_THERMOSTAT_SETPOINT 

 
Upon power up, allow 10 seconds for the RC-100BZ thermostat to initialize.  After 10 seconds, a controller can 
change setpoints, get current setpoints, and request the setpoints that are supported by thermostat. 

 
COMMAND_CLASS_SENSOR_MULTILEVEL 

 
The RC-100BZ thermostat uses this command class to report the actual temperature. 

 
COMMAND_CLASS_ASSOCIATION 

 
Upon power up, allow 10 seconds for the RC-100BZ thermostat to initialize.  After 10 seconds, a controller can 
issue an Association Set, Remove, or Get command.  The thermostat must be associated with a controller to 
provide feedback. 

 
COMMAND_CLASS_CONFIGURATION 

 
Upon power up, allow 10 seconds for the RC-100BZ thermostat to initialize.  After 10 seconds, a controller can 
change individual register settings for the outdoor temperature.  The Parameter Number is 67.  The size of the 
data is a 1 byte value.  The Value is the temperature to which the register is set. 

 
COMMAND_CLASS_THERMOSTAT_FAN_MODE 

 
Upon power up, allow 10 seconds for the RC-100BZ thermostat to initialize.  After 10 seconds, a controller can 
set the fan mode, get the current fan mode, and get the fan modes supported by the thermostat. 

 
COMMAND_CLASS_THERMOSTAT_FAN_STATE 

 
Upon power up, allow 10 seconds for the RC-100BZ thermostat to initialize.  After 10 seconds, a controller can 
request the state of the fan.

 

Содержание RC-100BZ

Страница 1: ...eptable in the country in which this equipment is to be installed INSTALLATION Before installing this thermostat 1 Read all of the installation instructions carefully 2 Read the Owner s Manual careful...

Страница 2: ...NG When mounting the RC 100BZ grasp the thermostat by the sides avoiding the keys and unsnap the base from the face Holding the base to the wall so that the word TOP is upright and facing you 1 Mark t...

Страница 3: ...tat push all excess wiring into the hole in the wall Plug the hole with the supplied insulating foam to ensure an accurate temperature reading by the thermostat Align the tabs of the thermostat face w...

Страница 4: ...times 2 O Terminal is energized for cooling B Terminal is energized for heating In most applications the reversing valve is energized for cooling and should be connected to the O terminal If the heat...

Страница 5: ...5 5 Figure 5...

Страница 6: ...6 2 To configure the display backlight to always be on set the JP2 Select Backlight Mode jumper to the ON position between the middle and bottom pin on the connector See Figure 6 3 To configure the di...

Страница 7: ...es off If the thermostat or system does not perform as stated above recheck all wiring See Troubleshooting Tips INSTALLER SETUP This section describes the items that the installer must setup as part o...

Страница 8: ...ions The thermostat can be configured with the following system options WITH NO EEC EEC 0 8 Auto changeover no fan with heat 1 9 Auto changeover fan on with heat 4 12 Manual changeover no fan with hea...

Страница 9: ...lays add 16 to each value The default setting is 1 04 Calibration offset This item is used to raise or lower the current temperature reading by 1 degree Fahrenheit or 1 2 degree Celsius If this item i...

Страница 10: ...default setting of 2 degrees F is recommended for all applications In special cases a setting of 3 or 4 may be used when precise control of temperature is not as important as highest energy efficiency...

Страница 11: ...oling system was in operation this week 17 System runtime Last week This item logs the amount of time hours that the heating and cooling system was in operation last week ANTICIPATION RC 100BZ anticip...

Страница 12: ...with energy saving settings recommended under the EPA Energy Star program When used with remote systems HAI recommends that the thermostat be configured as non programmable See Setup Item 03 Display O...

Страница 13: ...AND_CLASS_SENSOR_MULTILEVEL The RC 100BZ thermostat uses this command class to report the actual temperature COMMAND_CLASS_ASSOCIATION Upon power up allow 10 seconds for the RC 100BZ thermostat to ini...

Страница 14: ...After 10 seconds a controller can set the time of the internal clock INTEROPERABILITY WITH Z WAVE DEVICES A Z Wave network can integrate devices of various classes and these devices can be made by dif...

Страница 15: ...stat keys for test remove jumper SYMPTOM ACTION TO TAKE 1 Check Node ID 2 Check communications mode setting Control By Remote System Not Working 3 Check setup of the remote system Ensure that all setu...

Страница 16: ...W2 HEIL QUAKER 867 PH50 R G O C Y W1 W2 LENNOX HP19 HP20 V VR F R X M Y L LENNOX CB19 R G O C Y W1 L RHEEM RUDD PGB PFA PCB R G O X Y W2 L WEATHERTRON R G O B Y W U YORK E1CS E1FB E1FH R G O B Y W X...

Отзывы: