1
1
1
1
15 Filter
reminder
The thermostat logs the amount of time the system fan has been running. When this setting reaches 0, the
thermostat will display a reminder to replace the filter. The setting is the amount of days (24 hours of system
operation) before this reminder is displayed.
Days - Counting down from 10 - 0
The filter reminder can be disabled by setting this item to 60.
16
System runtime (This week)
This item logs the amount of time (hours) that the heating and cooling system was in operation this week.
17
System runtime (Last week)
This item logs the amount of time (hours) that the heating and cooling system was in operation last week.
ANTICIPATION
RC-100 anticipation is performed electronically and is independent of the type and load of the components in
the heating and cooling equipment. The RC-100 has electronic control based on proportional, integral, and
derivative components and maintains temperature to within 1 degree F. of the setting. Anticipation is not
adjustable on the RC-100.
OWNER'S MANUAL
Following Installer Setup, check the option boxes (
) in the Owner's Manual according to the configuration of
the thermostat.