Page 50
SUPERVISE INT SNDR
This enables or disables supervision of the Interior Horn Output, which monitors the wiring to the connected sirens. Factory
default is disabled.
SUPERVISE INT SNDR: 0
0=NO 1=YES
↕
SUPERVISE EXT SNDR
This enables or disables supervision of the Exterior Horn Output, which monitors the wiring to the connected sirens. Factory
default is disabled.
SUPERVISE EXT SNDR: 0
0=NO 1=YES
↕
ENABLE EMERGENCY KEYS
This enables or disables the functionality of the emergency keys on the console keypad. Factory default is enabled. Select the 1
(YES) key to enable the emergency keys. Select the 2 (NO) key to disable the emergency keys.
ENABLE EMERG KEYS: 1
0=NO 1=YES
↕
TIME DISPLAY
This allows you to choose between AM/PM and 24-HOUR time format.
TIME DISPLAY: 1
1=AM/PM 2=24HR
↕
DATE DISPLAY
This allows you to choose between MONTH/DAY and DAY/MONTH date format.
DATE DISPLAY: 1
1=MMDD 2=DDMM
↕
AC POWER FREQUENCY
Set this to the appropriate AC Powerline Frequency.
AC POWER FREQUENCY: 1
1=60HZ 2=50HZ
↕
DEAD LINE DETECT
NOTE: To disable OmniPro II from detecting a dead line, set this item to '0'; otherwise adjust only under direction of HAI.
This item adjusts the threshold that is used to determine when the phone line goes dead.
DEAD LINE DETECT: 8
0-15 0=DISABLE
↕
OFF HOOK DETECT
NOTE: Adjust only under direction of HAI.
This item adjusts the threshold that is used to determine when the phone line is going off hook.