background image

10

Hague Filter Owner's Manual

The air sulfur and air iron filter systems look and function much like any backwashing whole house filter; however, unlike these conventional filters, 

they use air as a regenerant . This atmospheric air (containing oxygen) helps convert iron or hydrogen sulfide into particles . These filters capture the 

particles of iron or hydrogen sulfide gas within the filter media . Your dealer has recommended the proper media depending on your local water 

conditions . In some cases where an acidic water condition (low pH) is present, the media may need to be periodically replenished if using this filter 

to raise the pH to an acceptable level . Consult dealer for this service . The system is pre-factory set to regenerate every (3) three days at midnight . 

The frequency and start time of backwash/regeneration is adjustable to meet local operating conditions and contaminant levels . Total backwash and 

recharge time is normally one half hour .

1.  GENERAL OPERATION:

 When the system is operating, one of four displays may be shown (#1-#4) and will alternate with the installing 

dealer’s name and phone number (#5) for future service . Pressing 

NEXT

 will alternate between the displays . 

1.

 

Time of Day Screen:

 Displays the current time of day, the day of the week, and flow rate . 

2. Flow Rate Screen:

 Displays the current treated water flow rate through the system in Gallons Per Minute . 

3. Capacity Remaining Screen:

 Displays the amount of gallons of treated water remaining until the system triggers a regeneration . 

4. Days to a Regen Screen:

 Displays the number of days until the system triggers a regeneration . Based on the days override value . 

5. Dealer Name Screen:

 Displays dealer specific name and phone number . This scrolling display will only appear if set by the dealer . 

If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN TODAY” will appear on the display .
If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons per minute flowing through the system .

2.

  

REGENERATION MODE: 

Typically, a system is set to regenerate at a time of no water usage . If there is a 

demand for water when the system is regenerating, untreated water will be delivered . When the system begins 

to regenerate, the display will include information about the step of the regeneration process and the time 

remaining for that step to be completed . The system runs through the steps automatically and will reset itself to 

provide treated water when the regeneration has been completed .

3.  MANUAL REGENERATION:

 Sometimes there may be a need to regenerate a unit before the control valve 

calls for it . This may be needed if a period of heavy water use is anticipated .

 

•  To initiate a manual regeneration at the next preset regeneration time, press and release the 

REGEN 

button . The words “REGEN TODAY” will flash on the display to indicate that the system will regenerate at 

the scheduled regeneration time (see the Programming Procedures section) . If you pressed the 

REGEN

 

button in error, pressing the button again will cancel the command .

 

•  To initiate a manual regeneration immediately, press and hold the 

REGEN

 button for three seconds . The 

system will begin to regenerate immediately . 

This command cannot be canceled.

 Once a manual regeneration is initiated, the unit will enter the first regeneration cycle position . Once the unit

 advances to its first position and subsequent positions thereafter, (see Start Up Instructions for regeneration sequence) 

the water filter will deliver water, but it will be untreated . 

1

FLOW RATE

GPM

8.0

CAPACITY REMAINING

2

5

TIME OF DAY

MON

PM

GPM

2:40

8

GAL

GPM

1600

8

GPM

3

8

3

DAYS TO A REGEN

4

555 5555555

DEALER NA

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGENERATION MODE

BACKWASH

8:22

MANUAL REGEN

REGEN TODAY

MON

GPM

2:40

8

PM

REGEN TODAY 

and 

TIME OF DAY 

will flash alternately if a regeneration 

is expected tonight.

REGEN

UP

DOWN

NEXT

CLOCK

Operati ng Displays and Maintenance

Содержание HFFE-1054

Страница 1: ...lter Iron and Sulfur Air Draw Filters OWNER S MANUAL AND INSTALLATION GUIDE For Models HFFE 1054 HFFE 1354 HFHS 1054 HFHS 1354 HFAIR 1054 HFAIR 1354 100037741 100037742 100037739 100037740 100037743 1...

Страница 2: ...rranty 26 Quick Reference Guide 27 YOUR WATER TEST Hardness______________________ gpg Iron___________________________ ppm pH____________________________ number Nitrates_______________________ ppm Mang...

Страница 3: ...and days to a regeneration are optional displays For more explanation consult the operating displays and maintenance section Pressing the NEXT button on a general operating screen will cycle through...

Страница 4: ...er flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Страница 5: ...subjected to room temperatures under 33 F 4 Do not subject the tank to any vacuum as this may cause an implosion and could result in leaking If there is a possibility a vacuum could occur please make...

Страница 6: ...o a subsurface drainage system or other safe location Remember to follow all local codes When installing the drain line on any backwashing filter especially filters that utilize air as the regenerant...

Страница 7: ...is necessary to relieve the pressure from the system Place filter into by pass mode Fig 2 Page 4 and release pressure by manually stepping through an entire regeneration sequence This will adequately...

Страница 8: ...REGEN UP DOWN NEXT CLOCK REGEN UP DOWN NEXT CLOCK TIME OF DAY MON GPM 2 40 8 PM Press NEXT to cycle to the next step or REGEN to return to the previous step STEP 1 Press and hold the NEXT and UP butt...

Страница 9: ...ing steadily to the drain clear and without the presence of air slowly open the inlet valve Restore power and momentarily press the button to advance the control to the REGENERANT DRAW DOWN position 4...

Страница 10: ...is installed GPM flashes on the display when water is being treated indicating gallons per minute flowing through the system 2 REGENERATION MODE Typically a system is set to regenerate at a time of no...

Страница 11: ...ERROR appears and flashes alternately with the dealer name and phone number record the ERROR number and contact your servicing dealer promptly This indicates that the control valve was not able to fu...

Страница 12: ...TER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are...

Страница 13: ...el in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Cont...

Страница 14: ...osition or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and...

Страница 15: ...GEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP mot...

Страница 16: ...losed The alarm buzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or discon...

Страница 17: ...o Part No Description Qty 1 CV4381 01 Hague Filter Cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV4377WF WF Replacement Board 1 5 CV3110 Drive gear 12 x 36 3 6 CV310...

Страница 18: ...V3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3001 1 body assembly downflow 1 CV3001UP 1 body assembly...

Страница 19: ...1 CHECK VALVE ASSEMBLY Item No Part No Description Qty 1 CH4642 WR A Air check valve assembly 1 Although no tools are necessary to assemble or disassemble the valve the Service Wrench shown in variou...

Страница 20: ...V3010 1F F injector assembly CV3010 1G G injector assembly CV3010 1H H injector assembly CV3010 1I I injector assembly CV3010 1J J injector assembly CV3010 1K K injector assembly not shown CV3170 O ri...

Страница 21: ...08 04 FTG Drain 1 Strt No Sil 1 Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elbow l...

Страница 22: ...Part No Description Qty 1 OZ1 A Ozone Kit Assembly 1 2 OZ1 CASE Enclosure Top Bottom and Clip cover not shown 1 3 33217 WRP3 Ozone Cell 1 not shown CJCPG 6PBLK 3 8 Compression Nut 1 not shown CH4642WR...

Страница 23: ...OLVENT Item Part No Description Qty CV3007 07 1 1 4 1 1 2 PVC solvent assembly 2 4 CV3352 Fitting 2 3 4 BRASS SHARK BITE Item Part No Description Qty CV3007 12 3 4 brass shark bite assembly 2 4 CV3628...

Страница 24: ...24 Hague Filter Owner s Manual This page intentionally left blank...

Страница 25: ...1 0 1 0 pH Range 6 8 to 9 0 6 8 to 9 0 Total Dimensions 10 W x 52 H 13 W x 62 H Weight Filled Lbs 106 5 164 Sulfur Filters Iron Air Filters 1 Op onal Ozone Generator not recommended for use on lters...

Страница 26: ...d is owned by the original owner This warranty does not cover expendable or misapplied medias or damages due to accident re ood freezing or any other Act of God We are not responsible for damages due...

Страница 27: ...DOWN buttons AM PM toggles at 12 3 Press 4 Adjust minutes with UP and DOWN buttons 5 Press 6 Adjust current day with UP and DOWN buttons 7 Press to complete and return to normal operation CURRENT DAY...

Страница 28: ...100037746 RevA0120 Iron and Sulfur Air Draw Filter Hague Quality Water Int l 4343 South Hamilton Road Groveport OH 43125 Phone 614 836 2115 Fax 614 836 5349...

Отзывы: