Haglof Digitech Скачать руководство пользователя страница 24

Digitech ENU rev. Feb 2011 

 

 

©Haglöf Sweden®AB 

Mantax Digitech 

 

- 24 -  

DECLARATION OF CONFORMITY 

According to the EMC Directive 89/336/EEG, 92/31/EEG & the Low Voltage Directive 73/23/EEG and 93/68/EEG including amendments by 

the CE-marking Directive 93/68/EEGType of equipment Caliper. Brand name or trade mark Haglöf Sweden®, Digitech. Type 

designation(s)/Model no(s) Digitech & DigiRadio. Manufacturer’s name, address, telephone & fax no Haglöf Sweden AB, Klockargatan 8, SE-

882 21 Långsele, Sweden Tel: + 46 620-25585, Fax: + 46 620-20581 The following standards and/or technical specifications, which comply 

with good engineering practice in safety matters in force within the EEA, have been applied: Testreport/ technical construction file/ 

normative document. Ref. No: 02012  Standard EN 50081-1, EN 55011 Class B  EN 50082-2, EN 61000-4-2, -3 Level 3. FPA prüfnummer 

3595, Kwf nr 1.06.3595. The product is CE-marked. As manufacturer/ the manufacturer’s authorized representative established within 

EEA,we declare under our sole responsibility that the equipment follows the provisions of the Directives stated above. 

W A RRA NT Y  A ND S E RV I C E  I NF O RMA T I ON  

Haglöf Sweden AB warrants that this product shall be free from defects in materials and workmanship, under normal intended use, for a 
period of 12 months after date of shipment. The warranty excludes the batteries, the accessories and any written materials. The warranty 
does  not  apply  if  the  product  has  been  improperly  installed,  improperly  calibrated  or  operated  in  a  manner  not  in  accordance  with  the 
user’s guide. Warranty is also automatically expired if the product has been opposed to external force and warranty is not applicable for 
cosmetic  defects.  The  one-year  limited  warranty  time  covers  obvious  fabrication  defects.  Defects  in  the  electronic  components  that  are 
impossible for the manufacturer to detect prior to assembling and shipping of the product may occur. Haglöf Sweden AB can in no case be 
responsible  for  problems  of  this  nature  and  has  no  liability  for  any  loss  of  business,  profits,  savings,  consequential  damages  or  other 
damages resulting from use of the products described. Signs of misuse, cosmetic damage, accidents or equal automatically withdraw the 
warranty.  The  warranty  is  valid  in  the  country  where  your  Haglöf  product  has  been  purchased.  A  product  covered  by  warranty  will  be 
object  to  exchange,  service,  and  repair  or  according  to  special  agreement  between  seller  and  buyer,  within  the  frames  of  the  limited 
warranty. Haglöf Sweden reserves the right to determine which option will be most suitable for each separate case after having examined 
and evaluated the product. 

 

IMPORTANT ISSUES: 

 

For a valid warranty, a copy of invoice or dated receipt of your purchase must be presented. The serial number of 
the returned product has to be clearly stated upon return. Go to 

http://www.haglofsweden.com/PDF/HaglofRMA.pdf

 for return form/turn to your supplier for assistance. 

 

The return freight to us is on buyer’s expense. After warranty repair or exchange, the return freight to you is on 
our expense. If warranty has expired or is null and void, all freights are on buyer’s expense.  

 

If no original invoice can be presented upon shipment, or if two years or more have passed from date of 
purchase, a customs fee will be added by the applicable customs authorities and possibly in receiving country as 
well. These fees are on buyers account.  

 

We perform repair and service of products where warranty has expired when possible. Cost estimation will be 
sent to you after evaluating the returned product for cost approval. Please also see above paragraph on customs 
fees.  

 

Please do not hesitate to contact us or any Haglöf Sweden AB representative for questions or comments! 

Any 

signs of misuse or negligence automatically withdraw our warranty commitments

  

S OF T W A RE  

 

© Copyrights of Haglöf Sweden AB Software belong to Haglöf Sweden AB. Unauthorized duplication is prohibited. Haglöf Sweden and 

DIGITECH are registered trademarks of Haglöf Sweden AB. Production is made in Sweden.  

Haglöf Sweden and its suppliers cannot warrant the performance or results when using the firmware, software or hardware, nor the 

documentation. No warranties or conditions are made; neither expressed nor implied, of merchantability, suitability or special fitness for 

any particular purpose. If software problems appear, please contact your programmer for support. Haglöf Sweden takes no responsibility 

for loss of income, time, or problems and delays due to problems in soft- or hardware of products. 

*Copyrights of all software & firmware 

made by Haglöf Sweden belong to Haglöf Sweden*

 Any lists and/or information of software for any Haglöf Sweden AB products should be 

considered as brief descriptions and not as a complete guide to what may and may not be available. For further details, please see 

ORGALIME SW01, General Conditions for Computer Software, and Supplement to ORGALIME S 2000 or ORGALIME SE 94.  

 

Содержание Digitech

Страница 1: ...MANTAX Digitech V1 6 ENGLISH USER S GUIDE...

Страница 2: ...jaws 7 Adjust the handle 8 Jaw angle 8 MENU SELECTIONS 9 Battery 10 LOCAL 10 1 key registration 1But 10 3 key registration 10 Double scale function 10 1 key registration 1But 10 3 key registration 11...

Страница 3: ...species 15 Edit Data 15 Delete 0 diameters 15 Two 0 diameters New plot 15 Three 0 diameters New List Stand 15 Export data 16 Identities 16 Radius 16 Result Example Standtable 17 Explanations 17 Exampl...

Страница 4: ...rev Feb 2011 Hagl f Sweden AB Mantax Digitech 4 Technical specification 23 Accessories 23 IR4 23 IR6 23 DigiRadio V1 6 23 DigiAntenn 23 Declaration of conformity 24 Warranty and Service Information 24...

Страница 5: ...owned and run production facilities the entire production process is under our control This ensures availability and reliable deliveries for you as well as prompt service and support when you need it...

Страница 6: ...gl f Sweden Vertex and Vertex Laser height measurers for receipt of height results The Digitech caliper is manufactured in three different lengths and several graduation options For trees that are lar...

Страница 7: ...E CALIPER JAWS Assemble the caliper jaws using the enclosed Allen key wrench and the screws with washers Tighten the screws using the Allen key Make sure the jaws are correctly assembled and guided in...

Страница 8: ...ntaining a small Allen key Use the Allen key to adjust the sliders and jaw angle for perfect run and alignment JAW ANGLE Adjust screw 1 until the handle runs smoothly Adjust screws 2 and 3 for the jaw...

Страница 9: ...rees and memory Show Inspect measured trees Transfer measured trees to PC with IR or Radio Set random generator for sample tree signal Set 1 key or 3 key function when measuring and use of IR or Radio...

Страница 10: ...delivered the Digitech caliper is set in 3 key registration mode 1 KEY REGISTRATION 1BUT Press the caliper jaws around the object to measure a diameter Select species by pressing the number as stated...

Страница 11: ...ing the L key pressed for a while it is possible to delete the latest registration made When doing this the total number of registrations is shown in the display and the updated total number after del...

Страница 12: ...d finishes with CR and LF Carrige Return Line Feed The receiving serial port should be set to 1200 8 N 1 Radio receiver DigiRadio V1 6 or IR receiver IR6 can be used as receiving module Ex 1224 CR LF...

Страница 13: ...d settings for data interpretation from the Digitech can be defined in the program Data from more than one caliper unit can be transferred and interpreted as one object You can also choose to perform...

Страница 14: ...does not work switch the serial port in the Settings menu in DigiCom 4 When data is received a new screen will open up in the PC Settings on how to interpret data from the Digitech can now be made CO...

Страница 15: ...ey can be ignored and deleted here TWO 0 DIAMETERS NEW PLOT Choose this if performing a circular sample plot measuring method THREE 0 DIAMETERS NEW LIST STAND Choose this option if you have several st...

Страница 16: ...ort as between 1cm Standtable 2cm Standtable Excel txt file Forward Step to the following screen where ID for the chosen list is set IDENTITIES Choose stand and partial stand names RADIUS If having ma...

Страница 17: ...208 PLOT BA m2 ha NUM ha 1 38 9 195 2 36 7 162 STANDTABLE CLASS CM Pine Spruce Birch Other Co Other Oak Beech TOT 10 12 1 1 14 16 1 1 18 20 1 1 20 22 2 2 22 24 1 1 24 26 1 1 28 30 1 1 32 34 1 1 36 38...

Страница 18: ...1 154 Pine 157 2 1 TestStand 1 part 2 1 154 Pine 244 3 1 TestStand 1 part 2 1 154 Pine 335 208 4 1 TestStand 1 part 2 1 154 Pine 118 5 1 TestStand 1 part 2 1 154 Pine 201 6 1 TestStand 1 part 2 2 154...

Страница 19: ...maining digits show the tree diameter in mm For example 11232345 1st register Code 1 123mm 2nd register Code 2 345mm LINE Data from the Digitech can be transferred online to DigiCom Choose LINE in the...

Страница 20: ...In the RAND menu random parameters for sample tree registrations can be set The form factor used in the sample tree generator is K x d 2 D 2 K quote between 0 and 99 d Captured diameter D Mean diamete...

Страница 21: ...the caliper jaw until desired value is featured in the display Tree species with a K value 00 will not be marked as sample trees SET One or more key function is set in this menu and Radio or IR trans...

Страница 22: ...Digitech caliper Remove the cover before mounting the antenna Data can be sent online when the user presses Enter see Line Data can also be sent as a file including all stored registration see PC Mak...

Страница 23: ...Signal Built in loud speaker Tests IP67 moist dust proof See Declaration of conformity Digitech radio UHF transceiver 433 92MHz ISM Industrial Scientific and Medical frequency band in compliance with...

Страница 24: ...and repair or according to special agreement between seller and buyer within the frames of the limited warranty Hagl f Sweden reserves the right to determine which option will be most suitable for eac...

Отзывы: