Function

System information

Detailed, specialised knowledge obtained from 

Hager through specific KNX training courses is 

required for full understanding of the system.

These training courses are not necessary for this 

installation. 

“Quicklink” configuration

The TIC XEVA205 card is compatible with the 

Hager TRPS120 radio transmitter, to be integrated 

into the new generation meter.

Typical scenario

•  Integration into a charging station for an 

XEV1Kxxx electric vehicle.

•  Communication with the new generation meter 

and electronic meters with a TIC output via the 

wired connection.

•  Communication with the new generation meter via 

the KNX RF connection (TRPS120 module).

If the 2 methods of communication (wire 

and RF) are used, the wired communication 

always takes priority.

Product compatibility

•  Compatible with the XEV1Kxxx three-phase or 

single-phase electric vehicle charging station 

range.

•  This TIC card does not require setting:

1. 

 with a previous generation TIC card from 

French electronic energy meters,

2.

  with a standard TIC from the new generation 

French energy meter.

Meaning of the card status LED

Once the product is set up and configured via the 

Quicklink method, the status LED 

6

 indicates:

LED 

6

LED 

status

Meaning

Off

OFF: LED deactivated/TIC off

Green

ON: LED activated/TIC on

TIC in standby: 

the TIC is 

present but it is not activated 

by the energy supplier. It only 

transmits the identification 

number of the energy meter. 

The customer must request 

TIC activation from its energy 

supplier.

Red

no link with the TRPS120 

module:

 the LED flashes red 

if the wired TIC is not used 

and if no radio link has been 

configured between the TIC 

card and the TRPS120 module.
no RF reception with the 

TRPS120 module: 

the LED 

flashes red if the wired TIC is not 

used and the scope between 

the TRPS120 radio transmitter 

and the TIC card is insufficient.
no TIC communication at the 

TRPS120 module input: 

the 

TRPS120 module is incorrectly 

or insufficiently plugged in or the 

TIC output of the new generation 

meter is not working.
error in the TIC 

data transmission frame

function (fct) pushbutton 

6

In Quicklink mode, press the pushbutton to select 

the function during the configuration phase (refer to 

the TRPS120 module instructions).

Connecting the TIC card

Connecting the TIC card to the controller: 

use the flat cable (2 x 10 pins) supplied and 

connect the J1 connector of the TIC/CHP card 

to the J2 connector of the Controller card.

1

I1 I2 A

Connecting the TIC card to the electronic 

meter

If you use wired connectivity to transmit 

information, the plug-in J2 quick connect 

terminal of the TIC/CHP card connects to the I1 

and I2 terminals of the electronic meters.

2

It is preferable to use a remote energy 

meter cable or, failing that, a telephone-

type twisted cable. An R02V cable should 

not be used.

Installing the TIC card

PZ 1

1

2

5

HagerEnergy GmbH, Ursula-Flick-Straße 8, 49076 Osnabrück, Germany