hager REQ5 X Series Скачать руководство пользователя страница 1

11

 6LE000719A

REQ5..X, REQ6..X

Door station VIDEO 2-wire

z

08/2015 - 6LE000719A

Elcom Kommunikation GmbH - Gottfried-Leibniz-Str.1 - D-74172 Neckarsulm - www.hager.com -

z

Safety instructions

Electrical equipment may only be installed and 

assembled by a qualifi ed electrician in accor-

dance with the relevant installation standards, 

guidelines, regulations, directives, safety and 

accident prevention regulations of the country.
When installing and laying cables, always com-

ply with the applicable regulations and stan-

dards for SELV electrical circuits.
These instructions are an integral component 

of the product and must be retained by the end 

user.

Design and layout of the device

(7)

(3)

(6)

(4)

(5)

(2)

(1)

Figure 1: Front

(1)  Front plate stainless steel

(2)  Microphone

(3)  Camera

(4)  Locating screw for camera

(Allen key supplied)

(5)  Twilight sensor for call button/loudspeaker

(6)  Button panel with call push-buttons

(7)  Cover strip for dismantling protection

(11)

(8)

(9)

(10)

(12)

(13)

Figure 2: Back

(8)  Adjustment button Upwards 

(9)  7-segment display 

(10) Selection button   

(11)  Adjustment button downwards

(12) Module connecting cable

(13) Connection terminal block

Function

The door station video works in the 2-wire bus 

system and enables communication via sound and 

image.

Correct use

 - for surface- or fl ush-mounted installation in spe-

cial housings (see Accessories)

 - Not compatible with intercom systems of other 

manufacturers

 - suitable for use exterior applications

Product characteristics

 - completely pre-assembled

 - protected against vandalism

 - with brushed 2 mm stainless steel front plate

 - Name plate can be changed from the front wit-

hout any special tools

 - One-man commissioning

 - Call push-button with acknowledge tone (can 

be switched off) and tactile feedback

 - Call button, light release or door release can be 

adjusted even without any function

 - durable, homogeneous, white LED call push-

button backlighting

 - Twilight controlled call push-button backlighting 

with adjustable switch-on brightness level

 - Opening of door station only with enclosed ope-

ning tool

 - break-proof fl ush-mounted call buttons

 - Colour camera

 - invisible, glare-free IR LED night lighting

 - temperature controlled camera heating for clear 

view

 - scratch-proof camera cover

 - Loudspeaker and microphone protected against 

sabotage

 - Volume and microphone sensitivity settable

 - Door release contact on 1 ... 10 s adjustable

 - Door release without previous call adjustable in 

single door systems

 - Safety rope as installation aid

Operation

Establish call (ringing)

 

Press the call push-button assigned to the 

desired subscriber.
If confi gured, the call push-button activation is 

confi rmed by an acknowledge tone. Addressed 

indoor stations are called.

Switch-on lights

A call push-button is confi gured and labelled for 

lighting control (light insert supplied).

 

Press the call push-button for lighting.
If confi gured, the call push-button activation is 

confi rmed by an acknowledge tone. The light 

contact of a line power supply is closed for the 

set time.

Label call push-button

 

Keep call push-button pressed on one side.
On the opposite side, the lever opening (14) is 

accessible for a screwdriver.

 

Position the screwdriver in the lever opening 

(14) and release the interlock (Figure 3).

 

Remove cover with name plate insert.

(14)

Figure 3: Removing name plate cover

(14) Lever opening

 

Label name plate insert if required.

 

Insert name plate insert, prepared foil or prepa-

red labelling strip into the cover and press on 

cover.

  Do not use any paper for the name plate insert, 

since moisture and UV light will damage the 

paper and labelling.

  UV-resistant foil with laser printing is suitable 

for labelling as well as labelling devices for 

labelling strip:

 - small buttons - 12 mm

 - medium buttons - 30 mm

Door stations with status indication

Dis-

play

Cause

Function/Lighting 

duration

A subscriber is 

called.

After 90 s without call 

acceptance or an operati-

on on the door station,   

goes out.

A subscriber 

accepts the 

door call.

 goes out,   lights up 

as long as the intercom 

connection is pressed 

down, max. 3 min. 

The door is 

unlocked.

Call not accepted:

 Symbol goes out and 

 lights up for the unlok-

king time set on the door 

station.

Call accepted:
In addition to the  , the 

 lights up for the un-

locking time set on the 
door station.   goes out 

approx. 5 sec after the 

 

symbol.

Table 1: Status indications of door station

Cleaning and care

Commercially available products for stainless 

steel and car paintwork care containing a wax 

component for conservation are recommended for 

cleaning and care.
  Do not use wire wool, wire brushes or any 

similar products for cleaning. This will prevent 

damage to the surface and accumulation of 

fl ash rust.

P

P

P

Information for electricians
Installation and electrical connection

DANGER!
Touching live parts in the installation 

environment can result in an electric 

shock!
An electric shock can be lethal!
Before working on the device or load, 

disconnect all associated circuit brea-

kers. Cover all live parts in the area!

ç

When installing door communication systems, 

comply with the general safety regulations for tele-

communications systems according to VDE 0800:

 - Separate routing of power and door communi-

cation cables with a minimum spacing of 10 cm

 - Partitions between power and door communica-

tion cables in shared trunkings

 - Use of standard telecommunications' cables, e. 

g. J-Y (St) Y with 0.8 mm diameter

Bus cables

 - J-Y(ST)Y or A-2Y(L)2Y

Use wrapped wire pair.

Recommendation white/yellow

 - CAT

Use wrapped wire pair

Recommendation orange/white

 - YR

Use adjacent wires

Mounting door station

Surface-mounted or fl ush-mounted housing is 

installed (see Assembly instruction housing).

The connection cables and indoor stations are 

connected to the line power supply while taking 

the maximum cable lengths and attenuations into 

account (see operating instructions of the line power 

supply).

 

The fastening elements supplied with the fl ush-

mounted housing must be assembled. To do 

this, loosen the nuts on the threaded bolts, slide 

the elements onto the bolts over the 2 nuts and 

then tighten.

  The support bracket (15) of the fastening 

elements must be located on the wall surface 

(Figure 4).

(15)

 

Figure 4: Installation position of fastening elements

(15) Support bracket of the fastening elements

 

Insert opening tool (16) into the mounting de-

vice of the lower fastening element (17) on the 

housing (Figure 5). 

(16)

(17)

Figure 5: Inserted opening tool

(16) Opening tool
(17) Fixing element

P

 

Attach the loops of the safety rope (17) to the 

upper left suspension of the door station and to 

the upper fastening element (16) in the housing. 

Place the door station for installation onto the 

opening tool (Figure 5).

(18)

(17)

Figure 6: installation position of door station

(18) Safety rope

Connect door station

 

Shorten connection cable of the door station 

and strip the required wires.

 

Pull off connection terminal block (13) from the 

video insert.

 

Connect the wire pair of the 2-wire bus cable 

to the terminals 

XX

 of the connection terminal 

block (Figure 7).

 

Connect door release to the terminals 

TT

 of 

the connection terminal block (fi gure 7 and 8) if 

required.

or:

 

For manipulation-protected installation, connect 

the door release to the contact 

 of the line 

power supply 

(Figure 9).

  The door release lead must not be inserted 

through the door station in order to protect 

against manipulation.

 

For call push-button backlighting and camera 

heating connect 12 V~ lead from the power 

transformer to the terminals 

~~

 of the connec-

tion terminal block (Figure 7).

(13)

Figure 7: Wired connection terminal block

  Information on the connection as a fl oor door 

station can be found in the operating instruc-

tions of the line power supply.

 

Attach connection terminal block to video insert.

P

P

Circuit symbols and elements of the circuit 

diagrams

Line power supply RMD

Power transformer

Door release

Video door station

Wrapped wire pair for 2-wire devices 

(recommendation: white/yellow wire pair)
Unwrapped wire pair, for e.g. for door release

Figure 8: Door release connection on the door station Figure 9: Connection of door station video with 

 

   manipulation-protected door release

Individual call push-

button address/function

Automatic call push-

button addressing

Door speaker

volume 

Microphone sensiti-

vity

Operating sig-

nal sound volume

Door release 

unlocking time

Door release 

function

set 

door address

Camera present

Call push-button 

Backlighting

settings

(switch-on bright-

ness level)

Display error 

codes (max. 5 can 

be saved)

Reset error codes

factory setting

Confi rm the call 

push-button to be set

 ...   = Call push-button address

 = Light push-button

 = Door release push-button

 = no function

Address/Function

saved,

 is displayed

 = Cancel

 = Start addressing

Addressing executed/cancelled, 

 is displayed

 ... 

Default setting 

Volume set,

 is displayed

 ... 

Default setting 

Sensitivity set.

 is displayed

 ... 

 = Acoustic signal off

Default setting 

Volume set,

 is displayed

 ...   Seconds

Default setting   seconds

Unlocking time set,

 is displayed

 = only with door call

 = also without door call

 

1)

Default setting 

Door release function is set, 

 is displayed

x

 

 ... x

 

x = received line

 address

Default setting 

Door address set,

 is displayed

 = No camera

 = with camera

Default setting: Audio 

     Video 

Camera option set, 

 is displayed

 ... 

 = Off

 = lowest value

 = highest value

 = always on

Default setting 

Backlighting set, 

 is displayed

 ...   Error codes

 = module communication

 = sticking call button

 = module address

 = no error present
 = Cancel

 = Reset

Error codes were deleted, 

 is deleted

Error codes were displayed, 

 is displayed

 = Cancel

 = Reset

Reset to the factory setting, in-

dication goes out

 

 

1) Door release functions without door call only possible single door systems 

Figure 10: Overview of system settings

Отзывы: