Information for electricians
Manual commissioning/device setting
Height [cm]
Status LED (5)
45
1 x yellow
50 (default)
3 x red
55
2 x red
60
1 x red
65
3 x blue
70
2 x blue
75
1 x blue
80
3 x green
85
2 x green
Table 6: Installation height and colour of the status LED
Setting mode 2: Establishing radio connection
Setting mode 2 is called up. The status LED (5) flashes purple-blue.
1
Switch off circuit breaker of the cooker/hob for 10 s.
2
Switch on fuse again.
The power control unit searches for the sensor unit automatically.
If connection is successful, the sensor unit acknowledges with three acoustic signals ( ).
The cookguard ends the automatic setting mode.
of
Fig. 10: Calibrating cooker type manually
Setting mode 3: Calibrating cooker type
Setting mode 3 is called up. The status LED (5) flashes yellow-green.
Two options are available for calibrating the cooker type.
Option 1: Cooker
and
oven are jointly connected to the power control unit (Bild 10, left).
1
Switch on the oven.
2
Press the operation button (1).
The sensor unit confirms the identification of the cooker type with acoustic and optical signals.
3
Switch off the oven.
Manual calibration in option 1 is completed.
Option 2: Hob is individually connected to the power control unit (Bild 10, right).
19