Information for electricians
Installation and electrical connection
The scanning voltage between
In
and
Out
may be a maximum of 24 V DC and must be at least 3 V.
The current between
In
and
Out
must be limited to a maximum of 10 mA.
Only DC voltage is permitted between the
In
and
Out
terminals.
In 1
Out 2
Out 1
In 2
AUX1
AUX2
Fig. 6: Connecting terminal (AUX)
for external signal generator
11
Fig. 7: Connect potential-free output
The device to be connected should already be preconfigured.
1
Remove the break-out opening (11) on the housing base (Bild 7).
2
Connect the potential-free output. Pay attention to the polarity of the connections!
3
Clamp the cable in the cable routing slot.
Sensor unit - Selecting the installation location
The sensor unit can optionally be installed on the wall above the cooker/hob or directly under the ex-
tractor hood (Fig. 8). The sensor unit monitors the temperature and use of the cooker/hob and switch-
es off the power supply in the event of an alarm.
1
Remove the mounting bracket (8) carefully from the sensor unit.
2
Insert batteries into the sensor unit.
The connection to the power control unit is established automatically. If the radio connection is
successful, the sensor unit emits two acoustic signals for confirmation.
3
Fasten the mounting bracket (8) to the sensor unit again.
4
Remove any grease and dirt from the mounting surface using the cleaning pad supplied.
5
Attach the sensor unit using the preinstalled adhesive strip (Fig. 8) (optional: Use supplied fixings).
Make sure that the sensor is aligned correctly.
The sensor unit must be installed in the middle above the cooker/hob.
15