BODYGUARD-T
Installation Instructions
I-EA00206
Rev 01, Rev Date: 05/08/2018
Page
2
of
12
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
3. PRECAUTIONS
q
Shut off all power going to header before attempting any wiring procedures.
q
Maintain a clean & safe environment when working in public areas.
q
Constantly be aware of pedestrian traffic around the door area.
q
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions
by the door.
q
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any
wires and cause damage to equipment.
4. MECHANICAL INSTALLATION
TIPS
•
The sensor must be firmly fastened to prevent vibration.
•
The sensor must not have any unwanted objects likely to move or vibrate in its path.
•
The sensor should be mounted flush with bottom of door header.
PREPARATION
To prepare the Bodyguard-T for mounting to the header, perform the following:
1.
Remove both endcaps from the Bodyguard-T. Each is attached by one Phillips head screw.
2.
Remove both lenses from Bodyguard-T by simply sliding them out at each end.
3.
Remove the center eye shield, taking care not to damage the light tube on the inner side of the shield. Simply pull out from the top
end and rotate out as shown in the image below.
4.
Slide the PCB out of the extrusion and set it aside.