1. DESCRIPTION 

 
The Hager Bodyguard-T (10BODYGUARDT) are self-monitored ready, overhead-mounted, diffused active infrared sensing devices that provide detection 
for triggering automatic, swing-door safety functions. These sensors are designed for use with all of Hager’s LO21 modules. When used with Hager’s 
lockout devices, these sensors are programmed to allow two different fields of detection – one for detection when the door is in the fully-closed position 
and the other for detection when the door is fully open. While the door is in the fully-open position, the Bodyguard-T extends its coverage back through 
the threshold area of the doorway, to provide coverage that will overlap with Hager’s motion sensors. 

As with all of Hager’s programmable sensing devices, full adjustability is achieved with the use of Hager’s hand-held remote control unit. This allows 
alteration of all available functions as well as inquiry of existing settings. Should the need arise, the  

Bodyguard-T

 may also be tuned by means of two sensor-mounted buttons contained on the PC board within the unit. With these two buttons, the 

Bodyguard-T’s field of detection can be altered without the use of the hand-held remote.  

If a complete door-mounted sensor (SuperScan) system is not used in addition to the Bodyguard-T, Hager recommends the use of a lockout safety 
beam to allow safety signaling if the zone is entered during a door closing cycle. 

NOTE:  

If utilizing monitoring, lockout modules may 

not

 be used.  If lockout modules must be used, monitoring is 

not allowed

NOTE:  For BODYGUARD-TC functionality, set Immunity to 3-HIGH.

 

 

2. SPECIFICATIONS 

 

DESCRIPTION 

SPECIFICATION 

Installation Height - Variable 

9’ 0” max. (recommended 6’ 6” – 8’ 0”) 

Mounting Angles  

Bodyguard-T only 
Bodyguard-T with Bodymount 

 
5°, 10° (factory default setting: 5°) 
0°, 5°, 10°  

Power Supply 

12 – 24 VAC / VDC ±10% 

Monitoring Request Input 

12 – 30 VDC required (polarity-sensitive) 
Min. pulse width 10 ms (active low) 

Frequency 

50 – 60 Hz 

Output 

Max. Voltage at contacts: 60 VDC / 125 VAC 
Max. Current at contacts: 1 A  
Max. switching power:  30 W (DC), 60 VA (AC) 

Relay Hold Time 

0.5 – 9 seconds 

Operating Temperature 

-22 – 140 °F 

Immunity 

Immune to electrical and radio frequency interference 

Cable 

4’ nine-conductor cable 

Weight 

1 lb 11 oz (765 g) 

Dimensions 

11.8” (305 mm) x 1.9” (51 mm) x 1.9” (46 mm) (L x H x W) 

Material 

Aluminum & ABS plastic 

Housing Color 

Black, anodized aluminum 

DEVICES COVERED IN THIS DOCUMENT: 

2-659-0332  

2-659-0034 

2-659-0333 

Содержание BODYGUARD-T

Страница 1: ... buttons contained on the PC board within the unit With these two buttons the Bodyguard T s field of detection can be altered without the use of the hand held remote If a complete door mounted sensor SuperScan system is not used in addition to the Bodyguard T Hager recommends the use of a lockout safety beam to allow safety signaling if the zone is entered during a door closing cycle NOTE If utili...

Страница 2: ...moving door parts will not catch any wires and cause damage to equipment 4 MECHANICAL INSTALLATION TIPS The sensor must be firmly fastened to prevent vibration The sensor must not have any unwanted objects likely to move or vibrate in its path The sensor should be mounted flush with bottom of door header PREPARATION To prepare the Bodyguard T for mounting to the header perform the following 1 Remo...

Страница 3: ...h ANSI 156 10 a lockout safety beam or door mounted safety side SuperScan s is needed in addition to the Bodyguard T sensor CAUTION FOR ALL APPLICATIONS REFER TO THE PATTERN CHARTS FOR WIDTH AND DEPTH IN THE APPLICABLE SECTION OF THIS GUIDE PATTERNS SHALL BE ADJUSTED TO ACHIEVE MAXIMUM DETECTION ZONES AND SHALL BE IN COMPLIANCE WITH ALL APPLICABLE SAFETY STANDARDS i e ANSI A156 10 INSTALLATION NOT...

Страница 4: ...nated at the control OR use the 7 pin terminal See diagram below The monitoring DIP switch must be turned OFF to function while in a non monitored status see page 7 If wiring the Bodyguard T to a Hager module such as an LO21 or an MC15 refer to the schematic for the respective module 2 Once wired feed the opposite end of the cable through the previously drilled wire passage hole MECHANICAL INSTALL...

Страница 5: ... that extends out from the face of the safety side of the door In this case the 0º setting would improve the location of the detection field across the threshold area of the doorway It is recommended that for most applications the unit be powered and walk tested at the pre set 5º angle After walk testing if the detection field needs to be changed proceed with changes to the angle setting as shown ...

Страница 6: ...two wires are swapped the Bodyguard T will NOT work correctly b Check to ensure that the voltage from the motor at the red and black wire of the lockout has at least 10 VDC A voltage that is too low may not be recognized by the lockout 2 If the door goes to the open position and a set up is completed successfully but then the door begins to close and immediately recycles open it is possible that t...

Страница 7: ...en The following functions may be independently adjusted for each door position Sensitivity Pattern Width Pattern Depth 2 The following functions apply to both door closed and door open positions Automatic Learn Time Immunity Frequency Output Configuration Door Control Mode Hold Time Interface Type 3 The Immunity modes include Medium Rain and High Snow During these modes learn time of the sensor w...

Страница 8: ... function Infrared Frequency Mode Frequency 1 Normal Low 2 Normal High 3 Quiet Low 4 Quiet High See QUIET MODE Interface 1 New Style 2 LO21 Old Style LO21 B K P S U LO LINX MC15 DP HUB Unlock Inquire Lock To UNLOCK the sensor Press the UNLOCK key once Red LED flashes slowly If flashing fast see Note below To LOCK the sensor Press the LOCK key twice OR press once then enter a 4 digit lock code If l...

Страница 9: ...eft Wide 8 Asymmetric Right Wide 9 Center Narrow See notes for PATTERN WIDTH or DEPTH below Pattern Depth 1 Deep threshold ON 2 Medium threshold ON open 3 Limited threshold ON 4 Deep threshold OFF 5 Medium threshold OFF closed 6 Limited threshold OFF See THRESHOLD note below See PATTERN WIDTH or DEPTH note below Sensitivity Door Open Closed 0 min 9 max default 7 for door open default 6 for door cl...

Страница 10: ...iately flash red followed by a sequence of green flashes The red flashes indicate the parameter and the green flashes indicate the setting of the particular parameter NOTE Pressing PB1 will toggle between the parameters and pressing PB2 will toggle between the range of adjustments for that particular setting Once you achieve the highest adjustment the value will roll over to the lowest setting upo...

Страница 11: ...BODYGUARD T Installation Instructions I EA00206 Rev 01 Rev Date 05 08 2018 Page 11 of 12 Hager Companies 139 Victor Street St Louis MO 63104 800 325 9995 www hagerco com 12 PATTERNS WIDTH DEPTH ...

Страница 12: ...e system Installers and service personnel are responsible for executing a risk assessment following each installation service performed ensuring that the sensor system installation is compliant with local national and international regulations codes and standards Once installation or service work is complete a safety inspection of the door gate shall be performed per the door gate manufacturer rec...

Отзывы: