background image

Rota

te 45˚ 

3-1/2"

(89mm)

3/4"

(19mm)

12"

(305mm)

Top of 
Door

B

Frame

(Center on Hinge)

(Center on Hinge)

2-3/4"

(70mm)

7/16"

(11mm)

2"

(51mm)

A

3/8"

(10mm)

1/2"

(13mm)

Speed regulating valves toward lock stile.

CONNECTING ROD

1. PARTS

3. INSTALL CLOSER

2. MARK AND DRILL HOLES   (

Right Hand Shown)

4. INSTALL CONNECTING ROD

5. INSTALL MAIN ARM

Select hand of door and the degree of door 
opening. Fold template on the corresponding line 
for desired degree and hand. Fold or cut upper 
corner illustrated on template and align template 
with the hinge edge of door. At the “Frame Stop 
Line” fold toward you and attach template to door. 
Mark, prep and drill/tap 1/4"-20 holes for closer 
body and parallel arm bracket mounting screws.

Use adjustable wrench to rotate spindle 45˚ counterclockwise for Right Hand 
Door or clockwise for Left Hand Door. Place main arm on spindle so that the 
“R” (Right Hand Door) or “L” (Left Hand Door) lines up with the spindle flat. 
Secure main arm and spindle by tightening spindle bolt.

Remove template and use 
mounting screws to install the 
closer body to the door and 
the parallel arm bracket to 
the frame soffit. Closer body 
should be oriented so that the 
speed regulating valves are 
toward the lock stile of door.

For parallel arm application only, remove regular arm / 
top jamb shoe. Attach connecting rod to the parallel 
arm plate.

5200 Series Door Closer - Parallel Arm

Installation Instructions

Meets ANSI A156.4

3

HAGER COMPANIES

 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149

Door Opening

To 120

*121 to 180

9-1/2"

(241mm)

3-3/4"

(95mm)

7"

(178mm)

1-1/4"

(32mm)

*Door/Wall/Hardware/Jamb 
  conditions permitting 