hager 4700 Series Скачать руководство пользователя страница 2

Page 2 of 3 

 

4700 Series Rim Exit Device 

Installation Instructions 

Grade 1 

I-ED00790 

Rev: 3   Rev Date: 7/16/2018 

1. CUT EXIT DEVICE TO LENGTH 

2. MARK DOOR AND DRILL MOUNTING HOLES 

 

 

3. INSTALL DEVICE 

4. INSTALL END CAP 

 

 

RECOMMENDED OVERALL EXIT DEVICE LENGTH = DOOR WIDTH - 4” 

The exit device is pre-cut for 36” and 48” wide door use.  For other door 
widths, cut exit device to appropriate length.  Recommended overall 
length of the exit device is equal to door width minus four inches.  Cut 
with hacksaw or metal cutting saw blade.  Deburr edges. 

Measure center line of exit device, typically 40” from finished floor.  Fold 
and apply template to door and up against stop.  Mark and drill holes as 
shown on template.  Be sure the vertical line of the exit device mounting 
holes is 2-1/4” from the face of the stop.  Do not drill center hole on strike 
until after strike has been mounted and adjusted.   

 

For metal doors, drill and tap 1/4”-20 machine screws for both exit device and 
strike.   

 

For wood doors, pre-drill 1/8” holes.   

 

If mounting trim, drill 5/16” clearance holes on exit device side (push side) of 
door and 1/2” holes on pull side.  Trim requires and additional 1/2” clearance 
hole for the trim actuating shaft (not required for dummy trim). 

 

If using sex bolts, drill 5/16” clearance holes on exit device side (push side) of 
door and 3/8” on pull side.   

Remove end cap from end cap bracket.  Mark hole locations by either using 
template or holding end cap bracket up against door.  Be sure exit device is 
level before inserting end cap bracket lip into end of device body.  Mark, 
drill and tap holes.  Install end cap bracket and end cap.  
 

 

For metal doors, drill and tap for 1/4”-20 machine screws. 

 

For wood doors, pre-drill 1/8” holes. 

 

For sex bolts, drill 5/16” clearance holes on exit device side (push side) 
and 3/8” on pull side. 

Screws 

Metal door/sex bolt: 
1/4”-20 machine screws (2) 
 
Wood door: 
#12 wood screws (2) 

Remove head cover from exit 
device chassis.  Mount exit 
device using the two 
mounting holes indicated on 
the template.   

Screws 

Metal door/sex bolt:   
1/4”-20 machine screws (2) 
 
Wood door:  #12 wood screws (2) 

If using trim, be sure to line up trim 
actuating shaft (tailpiece) with cam 
located on back of exit device chassis.   

Отзывы: