4600 SERIES CONCEALED VERTICAL ROD EXIT DEVICE
INSTALLATION INSTRUCTIONS FOR ALUMINUM DOORS
I
-
ED01933
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325
-
9995 www.hagerco.com
9. ATTACH DEVICE TO DOOR OR TRIM
A.
Press the push bar to retract sliding blocks.
B.
Insert the provided mounting screws through the hole in the sliding blocks and through the exit device base
plate.
C.
Tighten screws to posts in trim, sleeve nuts or threaded holes in door depending on your application.
Figure 9
-
1
Figure 9
-
2
Hole in
Sliding
Block
Mounting Screws
(1/4”
-
20 x
1”
long Pan Head)
10. HANG DOOR
A.
Install the door in the frame or move to an upright position to test latches.
11.
TEST OPERATION
A.
Ensure the all latches are in the Door Closed Position. (See Figures 11
-
1). If the latch is in the Door Open
Position, manually push it back into the Door Closed Position. (See Figure 11
-
2) Be careful to avoid sharp
Corners on the door notch moving the latch. If the latches do not move to the proper Door Closed Position,
loosen the adjustment locking screw and unscrew the fine adjustment screw by one
-
half turn. Continue
unscrewingthe fine adjustment screw until the latches are able to move into the Door Closed Position.
Retighten the adjustment locking screw.
Figure 11
-
2
Figure 11
-
1
Door Open
Position
Door Closed
Position
Figure 11
-
3
Adjustment
Locking
Screw
Fine Adjustment
Screw
Rev 3, Rev Date: 2/13/20
Page 8 of 10