3400 Series Electric Cylindrical Lock  

Electrical Specifications & Supplemental Instructions

 

 

I-LS02201 

 

REV 2, 4/18/2018 

27390102 

Page 1 of 3

 

FUNCTION DESCRIPTION

 

3480EL - Fail Safe Control [GREEN]

 

Outside trim is locked when power is applied and unlocked when power is removed (storeroom function when energized).  Lockset 
will unlock in the event of a power failure.

 

3480EU - Fail Secure Control [YELLOW]

 

Outside trim is unlocked when power is applied and locked when power is removed.  Lockset will lock in the event of a power 

failure. This is the default lock setup.

 

Key Function

 

When key cylinders are installed into locks, the latch bolt may be momentarily retracted from the outside with key even if lockset is 
electrically locked.

 

Request to Exit

 

Request to Exit (RX) is a SPDT switch that is mounted inside the interior trim of the lockset.  The RX switch monitors the activation 
of the inside trim.

 

ELECTRICAL SPECIFICATIONS

 

3480EL and 3480EU

 

3480RX

 

Quick Connect Pin Assignments

 

Motorized Locking and Unlocking provides 12V/24V 

Fail-Safe/Fail-Secure operation with low power 
consumption. 
 

Voltage:  12-24V AC/DC (11V – 30V) 
Current:  250 mA MAX Inrush, 10 mA MAX Holding  

Non-polarized leads 
Fail-Secure (EL) by Default 

 

 

Note: Warranty is void if electronics module is 

removed.

  

 

SPDT mechanical switch.  Mainly used 

as a dry contact monitoring switch. 

 

Voltage  

Current 

 

125 VAC  

3 AMP 

30 VDC  

2 AMP 

 

RX Wiring Diagram

 

Yellow Wire:  (common)

 

Red Wire:  (normally open)

 

Gray Wire:  (normally closed) 
 

 

 

EU/EL or RX only 

-

 

If the lock only has EU/EL or RX 
electric function the function will 
be wired directly into an 8 pin 
connector as shown in the image 
below.  The 8 pin connector can 
be plugged directly into a Hager 
Quick Connect Harness Cable 
during installation of the lock. 

-

 

Insert excess wire into the 
raceway prior to installing the 
lock body. 

-

 

See wire color reference charts 
on page 2 to complete wiring of 
full door assembly. 

 

 

2-Conductor Wire Run 

Distance 

12V/24V 

Wire 

Gauge 

125’/250’ 

22 

200’/400’ 

20 

300’/600’ 

18 

500’/1000’ 

16 

750’/1500’ 

14 

1250’/2500’ 

12 

 