EN
INSTALLING THE CLEANFIX® FAN COMPONENTS
8
3
Installing the Cleanfix
®
fan components
3.1
Inserting the Cleanfix
®
reversible fan
► Drill a 20 mm hole for the hydraulic hose and a 12 mm hole for the Hall
sensor cable in the lower right side of the shroud.
► Install the strain relief fitting included in the installation kit.
► Clean the fan drive mounting surface so that excessive axial and radial
runout is minimized.
► Insert first the Cleanfix® fan in the shroud.
► Secure the Cleanfix® flange with the supplied screws to the fan drive
► Loosen any belts that drive the fan pulley. This will allow for a more
accurate runout measurement.
► Check the axial and radial runout with a dial gauge. The radial and
axial run must not exceed 0,1 mm (0.004 inches).
► Guide the hydraulic hose and the Hall sensor cable from the inside of
the shroud through the strain relief fittings.