After connecting the electrical connector, tighten the retaining screw to the correct torque. 
If a problem is detected when connecting to the socket (e.g. dirt, bent contacts etc.), the cause must be 

rectified. 

During operation, make sure that the maximum permissible temperature at the connection is not exceeded. 

Defective devices cannot be repaired. 
The cable connections must be free of dirt and corrosion. 

It is forbidden to unplug or forcibly insert the plug from the power supply. 

Protect electrical connectors from dirt, aggressive substances (e.g. acids, alkalis, gases etc.), moisture and 
from not allowed temperatures. 

The connectors must be cleaned regularly. Use an antistatic cloth for cleaning. Disconnect from the power 

supply before cleaning. 

 
 

Form A  

Housing Material:  

 

 

PA6 GF30 

 

Cable gland thread:   

 

M20x1,5 

Cable diameter: 

 

 

6-8mm 

Tightening torque: 

 

 

1,8 ± 0,2Nm 

Poles:  

 

 

 

2 + PE 

Direction of protecting earth:  

12 h 

Contact distance:  

 

 

18 mm 

Contact material: 

 

 

CuZn, tin-plated 

Resistance:   

 

 

< 15mOhm 

Conductor cross-section: 

 

0,5-1,5mm

Max. tightening torque: 

 

0,3 Nm 

Wire protection: 

use  of  wire  end 
sleeves is recommended  

Gasket type: 

flat 

Fastening screw material: 

 

steel 4.8, zinc-plated 

Fastening screw size: 

M3 x 33,5mm (with cross recess) 

Fastening screw 

tightening torque: 

 

 

0,4 ± 0,1 Nm 

Voltage: 

 

 

 

 250 V + 15% 

Ambient temperature range   

-25°C - +90°C 

 

 

 