1.

Read Instructions

AII the safety and operating instructions of your  Hafler
equipment should be read before power is applied to
the equipment.

2.

Retain Instructions

These safety and operating instructions should be held

for future reference.

3.

Heed Warnings

All warnings on the equipment and in the operating

instructions are important and should be followed.

4. 

Follow

 instructions

All operating and use instructions are important and

should be followed.

5.

Heat

The equipment should be kept away from areas of high
temperature, such as heater vents, radiators, stoves/
ovens, fireplaces, etc.

6.

Ventilation
The equipment should be used  in an area suitable  for

proper ventilation. Care should be taken to not impede
airflow in and around the cabinet. Do not mount on a

carpeted shelf or in an enclosure consisting of more than

five sides. Allow for proper clearance above the equip-
ment.

7.

Water and Moisture

8.

The equipment should not be used in or around water  -

such as a bathtub, sink, or swimming area. Also, the
equipment should not be used in areas prone to flooding

- such as a basement.

Power Sources
The equipment should be connected only to a power
source of the same voltage and frequency as that listed
on the rear panel near the power cord entry point.

9.

Power Cord Protection

NOTICE 

-

 IMPORTANT SAFETY INFORMATION

DO NOT DISPOSE OF 

-

 KEEP FOR FUTURE REFERENCE

Safety Instructions

Power cords should be run so that they do not interfere

with the movement of  objects in the room 

-

 people, fan

blades, utility carts, etc. Also, care should be taken that

the cord is not pinched or cut, and placed so that it is not

in danger of being pinched or cut, as in under a rug,

around a tight corner, etc.

10.

11.

12.

13.

14.

15.

Grounding and Polarization

The power supply cord is of a polarized type designed

to reduce the risk of electric shock sustained from a live
cabinet. It is assumed to be of a suitable length for most
uses of the equipment. The use of extension cords and
power strips is discouraged unless they are of suitable
rating to deliver the required current for safe equipment

operation and can be used so that the polarization of
the plug is not defeated. If an extension cord is required,

it is important that the blades of the plug be able to insert

fully into the receptacle. Professional amplifiers with a

S-conductor line  cord must never have the ground pin

of the plug defeated.

Non-Use Periods
During extended periods of non-use the power supply

cord should be kept unplugged from the power source.

Cleaning
The equipment should be cleaned only as detailed by

the owners manual.

Object and Liquid Entry
Care should be taken so that objects and/or liquids,
such as cleaning fluids, are not spilled into the enclosure
of the equipment.

Damage Requiring Service

HafIer equipment should be serviced by qualified ser-

vice personnel when:

A.

B.

C.

D.

E.

The power supply cord or plug has been
damaged; or

Objects have fallen, or liquid has been spilled

into the equipment; or

The equipment has been exposed to rain; or

The equipment does not appear to operate

normally or exhibits a marked change in per-
formance; or

The equipment has been dropped, or the en-

closure damaged.

Servicing

The user should not attempt to service the equipment

beyond that which is described in the manual. All other
service should be referred to qualified service person-
nel.

-2-

Содержание PRO5000

Страница 1: ...Hafler INSTALLATION fbd OPERATION Please refer to this serial number in all communications regarding this equipment ...

Страница 2: ...et op eration and a variety of simple yet effective protection systems Above all however the PRO5000 maintains the well known Hafler tradition of superior sounding power amplifiers OVERVIEW OF AMPLIFIER The PRO5000 is a standard two rack height fan cooled design utilizing fully complimentary drive circuits and lateral type MOSFET output transistors The amplifier has full subtractor balanced input ...

Страница 3: ...nd placed so that it is not in danger of being pinched or cut as in under a rug aroundatightcorner etc 10 11 12 13 14 15 Grounding and Polarization The power supply cord is of a polarized type designed toreducetheriskofelectricshocksustainedfromalive cabinet It is assumed to be of a suitable length for most uses of the equipment The use of extension cords and power strips is discouraged unless the...

Страница 4: ... as to provide some protection against voltage surges and built up static charges Section 8 10 of the National Electrical Code ANSl NFPA No 70 1984 provides information with respect to the proper grounding of the mast and supporting structure grounding of the lead in wire to an antenna discharge unit size of grounding conductors location of antenna discharge unit connections to groundingelectrodes...

Страница 5: ...ine voltage than what is supplied in an attempt to obtain greater output power Such an attempt will very likely damage parts in the amplifier not rated for the higher voltages that will result and the warranty will be voided A 3 wire grounded power cord is supplied It must be connected to a properly grounded earthed AC receptacle for safety Do not break off the ground pin on the plug to avoid usin...

Страница 6: ...rminal is the connection No connections should be made to either black output terminal in this configuration OPERATION APPLYING POWER Standard practice is to turn power amplifiers on last and off first in the chain of electronics This minimizes the likeli hood of damage to the load from turn on and turn off transients generated by source equipment The PROS000 provides built in protection from such...

Страница 7: ...TION T201 Transformer DB201 Diode Bridge F201 10A Fuse SW201 Power Switch S W 2 0 2 Grounding Switch C201 C202 Capacitor 20 000 C203 Capacitor 01 UL approved C204 Capacitor 01 TS201 Inrush Limiter J201 J203 Binding Post Black J202 J204 Binding Post Red CLIP DETECTOR CHASSIS PARTS LIST PART TT PRO5000 SSH 609 FS 010 SWH 144 SWH 103 CER 209 CD 103A CD 103 20 SSH 618 CCH 110B CCH 11OR 6 ...

Страница 8: ......

Страница 9: ......

Страница 10: ...2A SS 102A ss 113 RMP 4 2431 RMP 4 4752 RC 4 470 RC 4 470 RC 4 680 RC 4 470 RC 4 470 RMP 4 1001 RMP 4 1001 RC 4 682 RMP 4 4752 RMP 4 2431 RC 4 271 R49 Rl4 R50 Rl5 R51 Rl6 R52 R l 7 R53 Rl8 R54 Rl9 R55 RZO R56 R21 R57 R22 R58 R 2 3 R59 R 2 4 R60 R25 R61 R26 R62 R 2 7 R63 R28 R64 R29 R65 R30 R66 R31 R67 R 3 2 R68 R33 R69 R 3 4 R70 R35 R71 R72 R73 R74 R75 R76 R77 R78 R79 R80 R81 R82 R85 R83 R86 R84 R...

Страница 11: ...with 10 ampere 3AG type fuses FACTORY SERVICE AND LIMITED WARRANTY If you encounter any difficulty or have any questions concerning your PRO5000 Amplifier please call our Customer service Department weekdays 8 a m to 3 30 p m Mountain Standard Time at 602 967 3565 Should you have any doubts as to whether the amplifier is malfunctioning and requires service please call us before sending in for repa...

Отзывы: