Hafele RH 430 LD Скачать руководство пользователя страница 3

INTRODUCTION

You have made an excellent choice by choosing the 

Dometic miniBar

.             

We are convinced that you will be satisfied with your new appliance in every way.
Silent in operation, the miniBar fulfils high quality standards and guarantees 
an efficient use of resources and energy during its entire working life, i.e. 
during manufacturing, use and disposal.
Please study the installation and operating instructions carefully before 
attempting to operate the miniBar.

FOR YOUR SAFETY

Warnings and Safety Advice

In the interests of children's safety:

When disposing of the refrigerator, remove all doors and leave the 
shelves inside. This prevents children from being accidentally trapped or 
suffocated in the refrigerator.

Never open the cooling unit - it is under high pressure.

Never store explosive substances, such as lighter fuel, petrol, ether or 
similar products in the miniBar.

The minibar is not suitable for the proper storage of medications.

The miniBar must be installed in such a way that accidental contact with 
the cooling unit (which heats up when in use) is impossible.

The appliance has to be connected to a properly earthed socket in line 
with the relevant valid country regulations.

Servicing must only be carried out by authorised service personnel.

Coolants

Ammonia is used as a coolant.
This is a natural compound also used in household cleaning agents (1 litre of 
Salmiak cleaner contains up to 200g of ammonia - about twice as much as is 
used in the refrigerator). Sodium chromate is used for corrosion protection 
(less than 2% of the coolant).
If a leak occurs (which can be easily detected due to the unpleasant smell):

Switch the device off (pull mains plug, if applicable);

Ventilate room thoroughly.

Inform hotel personnel.

For the safety of hotel guests and personnel, it has been established by              
inspectors that the coolant poses no threat to health.

WARRANTY AND CUSTOMER SERVICE

Warranty arrangements are in accordance with 

EC Directive 44/1999/CE and 

the

normal conditions applicable for the country concerned.

For warranty or other servicing, please contact our Dometic Service department. 
Any damage due to improper use is not covered by the warranty. The warranty 
does not cover any modifications to the appliance or the use of non-original 
Dometic parts; the warranty does not apply if the installation and operating 
instructions are not adhered to and no liability shall be entertained. Parts can be 
ordered throughout Europe from our Dometic Service department.  
When contacting customer service, please always state model, product, 
MLC-Code and serial number! You can find this information on the model 
label inside the device.

3

1.0

2.0

2.1

3.0

2.2

e.g.

Содержание RH 430 LD

Страница 1: ...0 LD G RH 441 LD RH 448 LD RH 460 LD RH 461 LDG RH 468 LD RH 436 D RH 438 D RH 447 D RH 448 D RH 468 D RH 455 LD RH 456 LD RH 456 LDE Type HC20 60 821 2693 61 DE INSTRUCTION FOR USE INSTALLATION INSTRUCTION ABSORPTION REFRIGERATOR article number 568 15 313 568 15 402 568 15 561 ...

Страница 2: ...he Doorhang 9 5 0 INSTRUCTION FOR USE 10 5 1 Initial Operation 10 5 2 Temperature Control 10 5 3 Automatic Defrost Function 10 5 4 Leakage Detection 10 5 5 Automatic Door Control ADC 11 5 6 Interior Light 12 5 7 Environmental Advice 13 5 8 Disposal 13 5 9 Energy Saving Tips 13 5 10 Declaration 13 5 11 Check List 14 5 12 Technical Data 15 TABLE OF CONTENTS Model No Product No Serial No These operat...

Страница 3: ...authorised service personnel Coolants Ammonia is used as a coolant This is a natural compound also used in household cleaning agents 1 litre of Salmiak cleaner contains up to 200g of ammonia about twice as much as is used in the refrigerator Sodium chromate is used for corrosion protection less than 2 of the coolant If a leak occurs which can be easily detected due to the unpleasant smell Switch t...

Страница 4: ...bel corresponds to the mains voltage Depending on the model the following parts can be found in the miniBar Cleaning Before operating the miniBar we recommend you clean it both inside and outside Use a soft cloth lukewarm water and a mild detergent Following this wash out the miniBar using clean water and dry thoroughly At annual intervals remove dust from fridge aggregate using a brush or soft cl...

Страница 5: ...gerator 5 Only the entire cooling unit must project into the duct as shown 6 Air passing through the duct must not be preheated by any source of heat 7 Ventilation grills if used must have openings of at least 200cm each Please follow the installation details below carefully Guarantee is valid for products installed as described only IMPORTANT 200 cm 20 mm Where a socket outlet is used for the mai...

Страница 6: ...30LD RH440LD G RH441LD RH460LD RH461LDG RH436D RH447D RH438 L D RH448 L D RH468 L D The miniBar must be screwed onto the cupboard using the lower hinges 4 6 1 Tighten screw 2 Put on cap 1 Tighten screw 2 Put on cap 4 6 1 4 6 2 ...

Страница 7: ... in the mains lead may not correspond with the coloured markings identifying the terminals in your plug proceed as follows 1 Connect the GREEN and YELLOW coloured wire to the plug terminal marked letter E or earth symbol or coloured green or green and yellow 2 Connect the BROWN coloured wire to the plug terminal marked letter L or coloured red 3 Connect the BLUE coloured wire to the plug terminal ...

Страница 8: ...here in the use A suitable replacement plug should then be fitted as given above Changing the Sliding Hinge possible with RH430LD RH436D RH438LD RH440LD RH441LD RH448 LD RH447D RH460LD RH468LD 8 4 8 1 2 3 4 Distance to cupboard door A A 1 When closed the cupboard door A must not lie against the rest of the surrounding cupboard area distance 1 2mm 2 There must be a distance of 6 8mm between the cup...

Страница 9: ...9 Changing the Doorhang RH436D RH447D RH430LD RH440LD G RH441LD RH460LD RH461LDG RH438LD RH448LD RH468LD 1 2 3 4 5 6 7 8 9 10 11 R 12 13 R L L 4 9 1 2 1 2 ...

Страница 10: ...tomatic Defrost Function The first defrosting phase commences 39 hours after the initial operation 5 1 and lasts for two hours After this the device operates for 22 hours at a time followed by a defrosting period of 2 hours The ice layer must never be removed using force nor must the defrosting process ever be accelerated using a heater The miniBar operates silently Leakage Detection Air sensor Th...

Страница 11: ...n electric circuit is closed or opened Accordingly this is registered and processed at the hotel reception Note Electrical rating The miniBar s wiring connection is situated at the rear of the appliance and consists of a 3 pin terminal strip 1 11 5 5 1 The red dot has disappeared now Using a red dot in the display window A point 3 the ADC shows that the miniBar s door has been opened 1 2 RH456LD E...

Страница 12: ...terior Light All other models When the door is opened the light in the cooling shelf is switched on via a sensor Changing the LED board 5 6 2 To obtain spare electronic boards please contact your Dometic Service Centre 1 Pull out the mains plug 2 Remove the reflector disk 3 Remove the defective bulb 4 Insert new bulb 5 Clip reflector disk back in 5 6 5 6 1 1 Pull out the mains plug 2 Remove the re...

Страница 13: ...materials and the proper disposal of the rest Energy Saving Tips If possible always store pre cooled goods Do not expose the miniBar to direct sunlight and do not place it close to a source of heat An unobstructed air circulation in the fridge aggregate must be ensured When removing goods only open the miniBar briefly Switch on the miniBar approx 12 hours prior to stocking Declaration of Conformit...

Страница 14: ...he device and let it run for 5 6 hours c Check whether repair is feasible If not exchange device Failure Poor Cooling Performance Possible Cause Self Help Authorised Service a The cooling aggregate is not sufficiently ventilated b The device is exposed to direct sunlight c The fridge door does not close tightly d Light permanently on when door closed e The fridge was stocked a short while ago a Ch...

Страница 15: ...1x450x505 563x486x474 563x486x474 Electrical Rating W 65 65 80 80 Power Consumption kWh 24h 0 9 0 9 1 0 1 45 Net Weight kg 21 24 5 20 23 Freestanding Freestanding Built in Built in Casing Metal Metal Gross Contents litres 30 40 cooled uncooled 30 40 Dimensions mm H x W x D 522x384x411 554x401x446 Electrical Rating W 65 65 Power Consumption kWh 24h 0 7 0 8 Net Weight kg 11 14 Power consumption meas...

Страница 16: ......

Отзывы: